1.Direct Application of Multiplex PCR on Stool Specimens for Detection of Enteropathogenic Bacteria.
Min Chul CHO ; Sin Ae NOH ; Mi Na KIM ; Kyoung Mo KIM
Korean Journal of Clinical Microbiology 2010;13(4):162-168
BACKGROUND: Causative bacterial agents of infectious diarrheal disease were traditionally diagnosed by stool cultures. Stool culture, however, has a problem because of relatively low sensitivity and long turnaround time. In this study, we evaluated multiplex PCR applied on stool specimens directly to diagnose enteropathogenic bacteria. METHODS: From June to September 2009, 173 diarrheal stools submitted for stool cultures were tested by Seeplex(R) Diarrhea ACE Detection kit (Seegene, Korea) to detect 10 enteropathogenic bacteria. Specimens were cultured for Salmonella, Shigella, Vibrio, and Yersinia. Late 50 specimens were also cultured for Campylobacter. The specimens positive for verotoxin-producing Escherichia coli (VTEC) were further subcultured for detecting enterohaemorrhagic Escherichia coli O157:H7. Electronic medical records were reviewed for clinical and laboratory findings. RESULTS: Of 173 specimens, multiplex PCR and cultures identified enteropathogens in 36 (20.8%) and 8 specimens (4.6%), respectively. While multiplex PCR detected 5 Salmonella, 15 Campylobacter, 1 Vibrio, 4 Clostridium difficiles toxin B, 5 Clostridium perfringens, 1 Yersinia enterocolitica, 5 Aeromonas, and 2 VTEC, cultures detected 5 Salmonella, 1 Vibrio, 1 Y. enterocolitica, 1 Aeromonas, and 2 E. coli O157:H7. CONCLUSION: Multiplex PCR would be useful to detect Campylobacter, VTEC and C. perfringens, as well as have equivalent sensitivity to conventional culture for ordinary enteropathogens such as Salmonella, Shigella, Vibrio, Y. enterocolitica. Direct application of multiplex PCR combined with conventional cultures on stool warrants remarkable improvement of sensitivity to diagnose enteropathogenic bacteria.
Aeromonas
;
Bacteria
;
Campylobacter
;
Clostridium
;
Clostridium perfringens
;
Diarrhea
;
Dysentery
;
Electronic Health Records
;
Escherichia coli
;
Multiplex Polymerase Chain Reaction
;
Salmonella
;
Shiga-Toxigenic Escherichia coli
;
Shigella
;
Vibrio
;
Yersinia
;
Yersinia enterocolitica
2.Sonographically Guided Core Biopsy of the Breast: Comparison of 14-Gauge Automated Gun and 11-Gauge Directional Vacuum-Assisted Biopsy Methods.
Nariya CHO ; Woo Kyung MOON ; Joo Hee CHA ; Sun Mi KIM ; Seung Ja KIM ; Sin Ho LEE ; Hye Kyung CHUNG ; Kyung Soo CHO ; In Ae PARK ; Dong Young NOH
Korean Journal of Radiology 2005;6(2):102-109
OBJECTIVE: To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. MATERIALS AND METHODS: We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. RESULTS: A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n = 24), the imaging-histologic discordance (n = 5), and the imaging findings showing disease progression (n = 20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (p = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. CONCLUSION: The outcomes of the sonographically guided core biopsies performed with the 11-gauge vacuum-assisted device were better than those outcomes of the biopsies performed with the 14-gauge automated gun in terms of underestimation, rebiopsy and the false negative rate, although these differences were not statistically significant.
Adolescent
;
Adult
;
Aged
;
Aged, 80 and over
;
Biopsy/instrumentation/*methods
;
Breast Neoplasms/*pathology/ultrasonography
;
Carcinoma in Situ/pathology
;
Carcinoma, Ductal/pathology
;
Comparative Study
;
Disease Progression
;
False Negative Reactions
;
Female
;
Humans
;
Middle Aged
;
Research Support, Non-U.S. Gov't
;
Retrospective Studies