Objective Study on efficacy of epileptic patients on treatment with modified Chaihu Guizhi De -coction(Chinese traditional medicine compounds )combined with anti-epilepsy drug.Methods 90 case of epileptic patients were randomly assigned to study group or control group ,45 case for each .The control group was treated only with anti-epilepsy drug , and the study group was treated with modified Chaihu Guizhi Decoction and anti -epilepsy drug.Observed and compared the treatment effect as well as the monthly average of seizure frequency of the epilepsy after treatment.Results The study group effective rate was 82.22%,which significant higher than the control group (64.44%).The study group's monthly average of seizure frequency was lower than the control group , the clinical effect between the control group and the study group were differences significantly (p<0.05).Conclusion Modified Chaihu Guizhi Decoction combined with anti -epilepsy drug can significantly reduce the seizure frequency of the epi-leptic patients in the treatment of epilepsy .It's worthy to be widely applied in clinical .
2.Establishment of a blood concentration detection system for everolimus in recipients after liver transplantation
Simei TAO ; Jiwei HUANG ; Haibo LI ; Yingcai ZHANG ; Yang YANG
Organ Transplantation 2021;12(5):595-
Objective To establish a detection system of ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for everolimus concentration in whole blood of liver transplant recipients. Methods The proteins of samples were precipitated with methanol and zinc sulfate, and everolimus-D4 was used as the internal standard. Phenomenex Kinetex PFP column was used. The mobile phase A was water (containing 2 mmol/Lammonium formate and 0.1% formic acid), and the mobile phase B was methanol (containing 2 mmol/L ammonium formate and 0.1% formic acid). The gradient elution was performed with the flow rate of 1 mL/min, the column temperature of 50 ℃ and the injection volume of 1 μL. The multi-reaction monitoring mode was used to quantitatively analyze with electrospray positive ionization. The UPLC-MS/MS detection system required only 100 μL of whole blood, and could achieve a sufficient lower limit of quantification without complicated sample preparation. The total running time was within 4.5 min. Linear regression (1/