1.Way of DIB Derived from DICOM Medical Image File
Chinese Journal of Medical Physics 2009;26(6):1500-1503,1512
Objective: According to clinical investigation, analysis on the storage format of DICOM3.0 medical images files and displaying them is the basis of medical image processing. It is very important for medical imaging technology. Methods: Firstly, with the DICOM standard, the format of the medical images is studied, mostly the format of the information header and data element. Then the DIB display of the DICOM images in Windows platform is put forward, using linear window-transformation. Results: It is successfully realized the display of CT、MR images. With the manual window-transformation, the displaying would be better. Conclusion: As the results show, the method studied in the paper can preferably realize the display of the DICOM medical images, meeting certain clinical needs, and laying a foundation for the following study.
2.Preparation and evaluation of monolithic molecularly imprinted stationary phase for S-naproxen
Demiao CHEN ; Qiang FU ; Wei DU ; Sijuan SUN ; Ping HUANG ; Chun CHANG
Journal of Pharmaceutical Analysis 2011;01(1):26-31
An S-naproxen (S-NAP) molecularly imprinted monolithic stationary phase (MIMSP) with specific recognition for S-NAP and naproxen (NAP) was prepared by in situ technique,utilizing 4-vinylpridine (4-VP) as a function monomer,ethylene glycol dimethacrylate (EDMA) as a cross-linking agent,and low-polar solvents (toluene and dodecanol) as porogenic solvents.The selectivity of the polymers for S-NAP and NAP was evaluated by high performance liquid chromatography (HPLC).The binding characteristics were tested by Scatchard analysis.Racemic NAP could be specifically separated to some extent.At the same time,NAP could be separated from ibuprofen under optimized conditions.Scatchard analysis showed that two classes of binding sites existed in the S-NAP-imprinted polymers,with their dissociation constants estimated to be 1.045 and 5.496 μM,respectively.The results demonstrate that S-NAP and NAP can be recognized specifically on the obtained MIMSP.
3.Preparation and evaluation of monolithic molecularly imprinted stationary phase for S-naproxen
Demiao CHEN ; Qiang FU ; Wei DU ; Sijuan SUN ; Ping HUANG ; Chun CHANG
Journal of Pharmaceutical Analysis 2011;01(1):26-31
An S-naproxen(S-NAP)molecularly imprinted monolithic stationary phase(MIMSP)with specific recognition for S-NAP and naproxen(NAP)was prepared by in situ technique,utilizing 4-vinylpridine(4-VP)as a function monomer,ethylene glycol dimethacrylate(EDMA)as a cross-linking agent,and low-polar solvents(toluene and dodecanol)as porogenic solvents.The selectivity of the polymers for S-NAP and NAP was evaluated by high performance liquid chromatography(HPLC).The binding characteristics were tested by Scatchard analysis.Racemic NAP could be specifically separated to some extent.At the same time,NAP could be separated from ibuprofen under optimized conditions.Scatchard analysis showed that two classes of binding sites existed in the S-NAP-imprinted polymers,with their dissociation constants estimated to be 1.045 and 5.496 μM,respectively.The results demonstrate that S-NAP and NAP can be recognized specifically on the obtained MIMSP.
4.Nomenclature standardization of radiotherapy in cervical cancer
Wanjia ZHENG ; Xiuying MAI ; Yiqi YOU ; Sijuan HUANG ; Yalan TAO ; Feng CHI ; Xinping CAO ; Chengguang LIN ; Xiaoyan HUANG ; Xin YANG
Chinese Journal of Radiation Oncology 2021;30(2):180-185
Objective:To standardize the naming of organ at risk (OAR) and target area during cervical cancer radiotherapy based on AAPM TG-263.Methods:After self-programming of Matlab software to implement the reading and resolution of radiotherapy structure files, the naming of each substructure was automatically output, recorded and restored. After naming all substructures, the structure names were classified by keywords. According to TG-263, a standard naming conversion table of OAR and target area was developed, and the classified structure names were standardized through procedures. Finally, the standardized named radiotherapy structure files were output and imported into the treatment planning system (TPS).Results:The radiation structure of 144 patients with cervical cancer was successfully transformed and displayed correctly in TPS. Before the transformation, the naming of OAR and target area lacked of uniform norms and standards, and the naming of the same structure significantly differed. After the transformation, 43 naming methods of OAR and 74 naming methods of the target area were unified into 20 and 8 naming methods, which were more convenient for staff understanding and communication.Conclusion:The standardization of cervical cancer radiotherapy structure naming can reduce the inconsistency of naming and provide reference for the standardized naming of pelvic tumors.
5.Dosimetric effects of volumetric modulated arc therapy plans for lung cancer caused by different dose algorithms and radiation field settings
Wanjia ZHENG ; Enting LI ; Sijuan HUANG ; Yunting ZHU ; Jinxing LIAN ; Mingli WANG ; Xiaoyan HUANG ; Xin YANG
Chinese Journal of Radiological Medicine and Protection 2022;42(9):671-677
Objective:To analyze the dosimetric differences of volumetric modulated arc therapy (VMAT) plans for lung cancer caused by different dose calculation algorithms and radiation field settings and thus to provide a reference for designing clinical VMAT plans for lung cancer.Methods:This study randomly selected 20 patients with lung cancer and divided them into four groups of VMAT plans, namely, a group adopting two fields and two arcs based on the AAA algorithm (2F2A_AAA), a group employing two fields and two arcs based on the AXB algorithm (2F2A_AXB), a group using two fields and two arcs based on the MC algorithm (2F2A_MC), and a group adopting one field and two arcs based on the MC algorithm (1F2A_MC). Then, this study evaluated the target coverage, high-dose control, dose homogeneity index (HI), conformity index (CI), and organs at risk (OARs) of the plans using different algorithms and radiation field settings.Results:The planning target volume (PTV) results of two fields combined with two arcs (2F2A) of three groups using different algorithms are as follows. 2F2A_MC achieved better results in both D1% and V 95% (the relative volume of the target volume surrounded by 95% of the prescribed dose) of planning gross target volume (PGTV) than 2F2A_AAA (D1%: t=-2.44, P=0.03; V95%:z=-2.04, P=0.04) and 2F2A_AXB (D1%: t=2.34, P=0.03; z=-3.21, P < 0.01). 2F2A_AXB outperformed 2F2A_AAA ( z=-3.66, P < 0.01) and was comparable to 2F2A_MC in terms of the CI of PGTV. Regarding OARs, 2F2A_AXB and 2F2A_MC decreased the V5 Gy of the whole lung by 0.68% ( z=-2.69, P=0.01) and 3.05% ( z=-3.52, P < 0.01), respectively compared to 2F2A_AAA. 2F2A_AXB achieved a whole-lung Dmean of 1776.44 cGy, which was superior to that of 2F2A_MC ( t=2.67, P=0.02) and 2F2A_AAA ( t=8.62, P < 0.01). Compared to 2F2A_AAA and 2F2A_MC, 2F2A_AXB decreased the V20 Gy of Body_5 mm by 1.45% ( z=-3.88, P < 0.01) and 2.01% ( z=-3.66, P < 0.01), respectively. The results of the two groups with different field settings showed that 1F2A_MC was superior to 2F2A_MC in both the CI of PTV1 and the HI of PTV2 (CI: t=2.61, P=0.02; HI: z=-2.20, P=0.03). Moreover, 1F2A_MC increased the Dmean of the whole lung by 26.29 cGy compared to 2F2A_MC ( t=2.28, P=0.04). Conclusions:Regarding the design of VMAT plans for lung cancer, the MC algorithm is suitable for the target priority and the AXB algorithm is suitable for the OAR priority. When only the MC algorithm is available, it is recommended to choose 1F2A in the case of target priority and select 2F2A in the case of OAR priority.
6.Correction of enhanced dynamic wedge factor and analysis of monitor unit calculation.
Sijuan HUANG ; Lixin CHEN ; Wufei CAO ; Wenzhao SUN ; Along CHEN ; Bojio LIU ; Bin WANG
Journal of Southern Medical University 2015;35(2):260-263
OBJECTIVETo study the correction of algorithm for Varian enhanced dynamic wedge(EDW) factors and compare the dose/monitor unit (MU) deviation measured at the central axis of EDW field with that obtained by manual calculation or using the treatment planning system.
METHODSEDW factors and dose were measured with Thimble ion chamber at 10 cm depth under the water for 6 MV and 10 MV photon on Varian linear accelerator. The corresponding calculations were done with the radiation treatment planning system. An analytic formula, namely the MU Fraction model, was used to calculate the EDW factor, which was corrected with a constant factor. The MU of conventional 2-D planning derived from manual calculating, treatment planning system, and actual measurements were compared.
RESULTSWith the measured results as the standard, the corrected manual calculation deviation of EDW factors was significantly reduced. For photon 6 MV, the maximum deviation reduced from 4.2% to 1.3% for 60° symmetry fields was, and from -4.7% to -1.8% for asymmetric fields. For photon 10 MV, the maximum deviation for all EDW fields was reduced from -3.0% to 1.1%. Comparison of the manual calculations with the measured results showed a MU deviation for symmetric fields within 2%, and more than 5% for some asymmetric fields. The deviation between the calculations of the treatment planning and the measured results was less than 1.5%.
CONCLUSIONConstant factor correction can effectively reduce the deviation of manual calculation. For MU calculation of EDW field in conventional 2-D dimensional treatment planning, the corrected results of symmetric fields meet clinical requirements. While the minimum distance between the field edge and the central axis was less than 4 cm in asymmetric fields, the corresponding special method, measurement or the treatment planning system should be used to calculate the dose/MU.
Algorithms ; Models, Theoretical ; Particle Accelerators ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted
7.Application of Jacobian determinant of reverse deformation field to evaluation of deformation registration algorithm
Enting LI ; Wanjia ZHENG ; Jinxing LIAN ; Weiting ZHU ; Su ZHOU ; Yaqi AN ; Sijuan HUANG ; Xin YANG
Chinese Journal of Radiological Medicine and Protection 2024;44(2):133-139
Objective:To effectively quantify and evaluate the quality of different deformation registration algorithms, in order to enhance the possibility of implementing deformation registration in clinical practice.Methods:The Jacobian determinant mean (JDM) is proposed based on the Jacobian determinant (JD) of displacement vector field (DVF), and the Jacobian determinant error (DJDE) is introduced by incorporating the JD of the inverse DVF. The optical flow method (OF-DIR) and fast demons method with elastic regularization (FD-DIR) were tested on nasopharyngeal and lung cancer datasets. Finally, JDM and DJDE with the Jacobian determinant negative percentage (JDNP), inverse consistency error (ICE) and normalized mean square error (NMSE) were used to evaluate the registration algorithms and compare the differences evaluation indicators in different tumor images and different algorithms, and the receiver operating curve (ROC) was analyzed in evaluation.Results:In lung cancer, OF-DIR outperformed FD-DIR in terms of JDM, NMSE, DJDE and ICE, and the difference was statistically significant( z = -2.24, -4.84, t = 4.01, 6.54, P<0.05). In nasopharyngeal carcinoma, DJDE, ICE and NMSE of OF-DIR were superior to FD-DIR, and the difference was statistically significant ( t = 4.46, -7.49, z = -2.22, P<0.05), but there was no significant difference in JDM ( P>0.05). In lung cancer and nasopharyngeal carcinoma, JDNP of OF-DIR was worse than that of FD-DIR, and the difference was statistically significant ( z = -4.29, -4.02, P<0.01). In addition, DJDE is more specific and sensitive on ROC curve (AUC=0.77), and has different performance result for tumor images at different sites. Conclusions:The JDM and DJDE evaluation metrics proposed are effective for deformation registration algorithms. OF-DIR is suitable for both lung cancer and nasopharyngeal carcinoma, while the influence of organ motion on the registration effect should be considered when using FD-DIR.
8.Correction of enhanced dynamic wedge factor and analysis of monitor unit calculation
Sijuan HUANG ; Lixin CHEN ; Wufei CAO ; Wenzhao SUN ; Along CHEN ; Boji LIU ; Bin WANG
Journal of Southern Medical University 2015;(2):260-263
Objective To study the correction of algorithm for Varian enhanced dynamic wedge(EDW) factors and compare the dose/monitor unit (MU) deviation measured at the central axis of EDW field with that obtained by manual calculation or using the treatment planning system. Methods EDW factors and dose were measured with Thimble ion chamber at 10 cm depth under the water for 6 MV and 10 MV photon on Varian linear accelerator. The corresponding calculations were done with the radiation treatment planning system. An analytic formula, namely the“MU Fraction model”, was used to calculate the EDW factor, which was corrected with a constant factor. The MU of conventional 2-D planning derived from manual calculating, treatment planning system, and actual measurements were compared. Results With the measured results as the standard, the corrected manual calculation deviation of EDW factors was significantly reduced. For photon 6 MV, the maximum deviation reduced from 4.2%to 1.3%for 60° symmetry fields was, and from-4.7%to-1.8%for asymmetric fields. For photon 10 MV, the maximum deviation for all EDW fields was reduced from-3.0% to 1.1%. Comparison of the manual calculations with the measured results showed a MU deviation for symmetric fields within 2%, and more than 5%for some asymmetric fields. The deviation between the calculations of the treatment planning and the measured results was less than 1.5%. Conclusion Constant factor correction can effectively reduce the deviation of manual calculation. For MU calculation of EDW field in conventional 2-D dimensional treatment planning, the corrected results of symmetric fields meet clinical requirements. While the minimum distance between the field edge and the central axis was less than 4 cm in asymmetric fields, the corresponding special method, measurement or the treatment planning system should be used to calculate the dose/MU.
9.Correction of enhanced dynamic wedge factor and analysis of monitor unit calculation
Sijuan HUANG ; Lixin CHEN ; Wufei CAO ; Wenzhao SUN ; Along CHEN ; Boji LIU ; Bin WANG
Journal of Southern Medical University 2015;(2):260-263
Objective To study the correction of algorithm for Varian enhanced dynamic wedge(EDW) factors and compare the dose/monitor unit (MU) deviation measured at the central axis of EDW field with that obtained by manual calculation or using the treatment planning system. Methods EDW factors and dose were measured with Thimble ion chamber at 10 cm depth under the water for 6 MV and 10 MV photon on Varian linear accelerator. The corresponding calculations were done with the radiation treatment planning system. An analytic formula, namely the“MU Fraction model”, was used to calculate the EDW factor, which was corrected with a constant factor. The MU of conventional 2-D planning derived from manual calculating, treatment planning system, and actual measurements were compared. Results With the measured results as the standard, the corrected manual calculation deviation of EDW factors was significantly reduced. For photon 6 MV, the maximum deviation reduced from 4.2%to 1.3%for 60° symmetry fields was, and from-4.7%to-1.8%for asymmetric fields. For photon 10 MV, the maximum deviation for all EDW fields was reduced from-3.0% to 1.1%. Comparison of the manual calculations with the measured results showed a MU deviation for symmetric fields within 2%, and more than 5%for some asymmetric fields. The deviation between the calculations of the treatment planning and the measured results was less than 1.5%. Conclusion Constant factor correction can effectively reduce the deviation of manual calculation. For MU calculation of EDW field in conventional 2-D dimensional treatment planning, the corrected results of symmetric fields meet clinical requirements. While the minimum distance between the field edge and the central axis was less than 4 cm in asymmetric fields, the corresponding special method, measurement or the treatment planning system should be used to calculate the dose/MU.
10.Study of standardizing nomenclatures for organs at risk of nasopharyngeal carcinoma via the contouring content-based image retrieval method
Xiuying MAI ; Shen HUANG ; Zhenfang ZHONG ; Wanjia ZHENG ; Shuxian CHEN ; Guangsen HUANG ; Su ZHOU ; Sijuan HUANG ; Yunfei XIA ; Xiaoyan HUANG ; Xin YANG
Chinese Journal of Radiation Oncology 2021;30(8):803-810
Objective:Based on the AAPM TG-263, a Content-Based Standardizing Nomenclatures (CBSN) was proposed to explore the feasibility of its standardization verification for organs at risk (OAR) of nasopharyngeal carcinoma (NPC).Methods:The radiotherapy structure files of 855 patients with nasopharyngeal carcinoma (NPC) receiving intensity-modulated radiotherapy (IMRT) from 2017 to 2019(15 of whom showed clinical anomalous structures) were retrospectively collected and processed. The Matlab self-developed software was used to obtain the image position, geometric features, first-order gray histogram, and the Gray-level Co-occurrence Matrix′s texture features of the OAR contour outlined by the doctor to establish the CBSN Location Verification model and CBSN Knowledge Library. Fisher discriminant analysis was employed to establish a CBSN OAR classification model, which was evaluated using self-validation, cross-validation, and external validation, respectively.Results:99%(69/70) of the simulated anomalous structures were outside the 90% reference range of the CBSN Knowledge Library and the characteristic parameters significantly differed among different OARs (all P<0.001). The accuracy rates of self-validation, cross-validation and external verification of the CBSN OAR classification model were 92.1%, 92.0% and 91.8%, respectively. Fourteen cases of clinical abnormal structures were successfully detected by CBSN with an accuracy rate of 93%(14/15). In the simulation test, the accuracy of the left and right location verification reached 100%, such as detecting the right eye lens named Len_L. Conclusion:CBSN can be used for OAR verification of NPC, providing reference for multi-center cooperation and standardized radiotherapy of NPC patients.