1.PET imaging in liver transplantation for primary hepatocarcinoma
Sijuan ZOU ; Dong CHEN ; Xiaohua ZHU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2015;35(1):71-74
Liver transplantation (LT) is effective for suitable patients with HCC and may be the only curative treatment for those with unresectable HCC.The outcomes of LT for HCC are closely related with the assessment of transplantation candidates,management of patients on the waiting list and postoperative surveillance for HCC recurrence.PET imaging plays a significant role in LT process.The applications of PET imaging in LT for HCC are reviewed in this article.
2.Determination of sulfydryl-containing drugs by reverse flow injection chemiluminescence analysis
Guangbin ZHANG ; Xianmin CHEN ; Haiyan LI ; Hongling YU ; Sijuan SUN ; Yuhai TANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2010;31(1):125-128
Objective To establish a rapid, accurate and sensitive chemiluminescence method for determining sulfydryl-containing drugs. Methods In sulfuric acid solution, glyoxal could be oxidized by potassium permanganate, and weak chemiluminescence could be observed. Chemiluminescence signal could be enhanced in the presence of sulfydryl-containing drugs. Thus, on this basis we established a new method of determining the concentration of sulfydryl-containing drugs with flow injection chemiluminescence analysis. Results Under the optimized conditions, the linear range of methimazole, captopril and acetylcysteine was 1.0×10~(-8)- 5.0×10~(-6), 7.0×10~(-8)-1.0×10~(-6) and 3.0×10~(-8)-1.0×10~(-6)g/mL, respectively. The limit of detection of methimazole, captopril and acetylcysteine was 1.0, 3.9 and 3.7ng/mL, respectively. Conclusion The method was successfully applied to determine the three drugs that contain sulfydryl. Compared with the results of pharmacopeia methods, the results we obtained were satisfactory.
3.Preparation and evaluation of monolithic molecularly imprinted stationary phase for S-naproxen
Demiao CHEN ; Qiang FU ; Wei DU ; Sijuan SUN ; Ping HUANG ; Chun CHANG
Journal of Pharmaceutical Analysis 2011;01(1):26-31
An S-naproxen (S-NAP) molecularly imprinted monolithic stationary phase (MIMSP) with specific recognition for S-NAP and naproxen (NAP) was prepared by in situ technique,utilizing 4-vinylpridine (4-VP) as a function monomer,ethylene glycol dimethacrylate (EDMA) as a cross-linking agent,and low-polar solvents (toluene and dodecanol) as porogenic solvents.The selectivity of the polymers for S-NAP and NAP was evaluated by high performance liquid chromatography (HPLC).The binding characteristics were tested by Scatchard analysis.Racemic NAP could be specifically separated to some extent.At the same time,NAP could be separated from ibuprofen under optimized conditions.Scatchard analysis showed that two classes of binding sites existed in the S-NAP-imprinted polymers,with their dissociation constants estimated to be 1.045 and 5.496 μM,respectively.The results demonstrate that S-NAP and NAP can be recognized specifically on the obtained MIMSP.
4.The research and strategy about the current situation about the analysis of cellular morphology in Tibet region
Quangui SHI ; Dongfang FENG ; Sijuan DING ; Hongzhang CHEN ; Baohong QI ; Huaying SHI
International Journal of Laboratory Medicine 2014;(8):1007-1008
Objective To understand the current situation and level of clinical laboratory about the analysis of cellular morphology in Tibet region .Methods Authors investigated the information about the staff of clinical laboratory testing the patient′s blood smear under microscope ,executing the rules and regulations by using standard questionnaires .Results Some of the clinical laboratory didn′t founded the rule and standardization of rechecking about abnormal blood routine (5/15 ,33 .3% ) .Some of the divi-sion leadership didn′t pay enough attention to the staff′s basic operation (2/15 ,13 .3% ) .Most of the staff didn′t being trained about cellular morphology in special purpose workshop (6/43 ,88 .8% ) .Some of the hospital didn′t carried out the chemistry stai-ning about blood cells(10/15 ,66 .7% ) .Conclusion It′s important to promote the quality and level about the analysis of cellular morphology in Tibet region .
5.Preparation and evaluation of monolithic molecularly imprinted stationary phase for S-naproxen
Demiao CHEN ; Qiang FU ; Wei DU ; Sijuan SUN ; Ping HUANG ; Chun CHANG
Journal of Pharmaceutical Analysis 2011;01(1):26-31
An S-naproxen(S-NAP)molecularly imprinted monolithic stationary phase(MIMSP)with specific recognition for S-NAP and naproxen(NAP)was prepared by in situ technique,utilizing 4-vinylpridine(4-VP)as a function monomer,ethylene glycol dimethacrylate(EDMA)as a cross-linking agent,and low-polar solvents(toluene and dodecanol)as porogenic solvents.The selectivity of the polymers for S-NAP and NAP was evaluated by high performance liquid chromatography(HPLC).The binding characteristics were tested by Scatchard analysis.Racemic NAP could be specifically separated to some extent.At the same time,NAP could be separated from ibuprofen under optimized conditions.Scatchard analysis showed that two classes of binding sites existed in the S-NAP-imprinted polymers,with their dissociation constants estimated to be 1.045 and 5.496 μM,respectively.The results demonstrate that S-NAP and NAP can be recognized specifically on the obtained MIMSP.
6.Targeted imaging and therapy of prostate cancer by radionuclide labeled small molecule inhibitors of prostate specific membrane antigen
Lixing CHEN ; Sijuan ZOU ; Xiaohua ZHU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2018;38(1):53-58
Prostate specific membrane antigen (PSMA) overexpresses in most prostate cancer (PCa) lesions and plays an important role in the early diagnosis and preoperative staging,clinical decision making,recurrence and metastasis detection as well as targeted therapy.Radionuclide (especially 68Ga and 177Lu) labeled multiple small molecule inhibitors of PSMA have been wildly used in SPECT,PET imaging on PCa,and play an important role in the treatment of metastatic castration resistant prostate cancer (mCRPC).This review summarizes the development in these fields.
7.Correction of enhanced dynamic wedge factor and analysis of monitor unit calculation.
Sijuan HUANG ; Lixin CHEN ; Wufei CAO ; Wenzhao SUN ; Along CHEN ; Bojio LIU ; Bin WANG
Journal of Southern Medical University 2015;35(2):260-263
OBJECTIVETo study the correction of algorithm for Varian enhanced dynamic wedge(EDW) factors and compare the dose/monitor unit (MU) deviation measured at the central axis of EDW field with that obtained by manual calculation or using the treatment planning system.
METHODSEDW factors and dose were measured with Thimble ion chamber at 10 cm depth under the water for 6 MV and 10 MV photon on Varian linear accelerator. The corresponding calculations were done with the radiation treatment planning system. An analytic formula, namely the MU Fraction model, was used to calculate the EDW factor, which was corrected with a constant factor. The MU of conventional 2-D planning derived from manual calculating, treatment planning system, and actual measurements were compared.
RESULTSWith the measured results as the standard, the corrected manual calculation deviation of EDW factors was significantly reduced. For photon 6 MV, the maximum deviation reduced from 4.2% to 1.3% for 60° symmetry fields was, and from -4.7% to -1.8% for asymmetric fields. For photon 10 MV, the maximum deviation for all EDW fields was reduced from -3.0% to 1.1%. Comparison of the manual calculations with the measured results showed a MU deviation for symmetric fields within 2%, and more than 5% for some asymmetric fields. The deviation between the calculations of the treatment planning and the measured results was less than 1.5%.
CONCLUSIONConstant factor correction can effectively reduce the deviation of manual calculation. For MU calculation of EDW field in conventional 2-D dimensional treatment planning, the corrected results of symmetric fields meet clinical requirements. While the minimum distance between the field edge and the central axis was less than 4 cm in asymmetric fields, the corresponding special method, measurement or the treatment planning system should be used to calculate the dose/MU.
Algorithms ; Models, Theoretical ; Particle Accelerators ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted
8.Comparison of 68Ga-PSMA-617 and MRI in diagnosis and staging of primary prostate cancer
Sijuan ZOU ; Shuang SONG ; Lixing CHEN ; Jianyuan ZHOU ; Zhaoting CHENG ; Xiaohua ZHU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2020;40(12):710-715
Objective:To compare the performance of 68Ga-prostate specific membrane antigen (PSMA) PET/CT and MRI in preoperative diagnosis and staging of primary prostate cancer. Methods:Twenty-four patients with prostate cancer, who underwent preoperative 68Ga-PSMA PET/CT and prostate MRI in Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology between April 2018 and December 2019, were retrospectively enrolled. The pathological and follow-up results were considered as the gold standard, and diagnostic efficiencies of the 2 imaging methods were compared per patient and per type of lesions (seminal vesicle invasion, bladder neck invasion, lymph node metastasis and bone metastasis). The χ2 test was used for data analysis. Results:Prostate cancer was confirmed by pathology in 24 patients, including 6 cases with both seminal vesicle and bladder neck invasion, 5 cases with seminal vesicle invasion and 3 cases with invasion of bladder neck. Gleason scores in patients were as follow: 7 in 9 patients, 8-9 in 15 patients. The detection rates of 68Ga-PSMA PET/CT and MRI for primary prostate cancer were both 100%(24/24). The sensitivity, specificity and accuracy of 68Ga-PSMA PET/CT and MRI for detecting seminal vesicle invasion were 10/11, 13/13, 95.8%(23/24) and 9/11, 11/13, 83.3%(20/24), respectively. The specificity and accuracy were significantly different ( χ2 values: 6.231, 13.470, both P<0.05). The sensitivity, specificity and accuracy of 68Ga-PSMA PET/CT and MRI for detecting bladder invasion, which were 7/9, 13/15, 83.3%(20/24) and 3/9, 14/15, 70.8%(17/24), respectively, were not significantly different( χ2 values: 1.285, 0.164, 2.880, all P>0.05). Furthermore, the sensitivity, specificity and accuracy of 68Ga-PSMA PET/CT for detecting pelvic lymph node metastasis were 11/11, 13/13 and 100%(24/24), respectively, and those of MRI for evaluating pelvic lymph node metastasis were 6/11, 11/13 and 70.8%(17/24), and the specificity of the 2 methods were significantly different ( χ2=6.231, P<0.05). All the 5 patients with pelvic bone metastasis were positive on 68Ga-PSMA PET/CT imaging, but only 2 of them were positive on MRI. Information from 68Ga-PSMA PET/CT changed pelvic TNM stage in 41.7%(10/24) patients who underwent MRI for initial staging. Conclusions:68Ga-PSMA PET/CT imaging and MRI can both accurately detect intermediate- to high-risk primary prostate cancer and seminal vesicle invasion. 68Ga-PSMA PET/CT imaging is superior to MRI for evaluating lymph nodes and bone metastasis. 68Ga-PSMA PET/CT provides high accuracy for preoperative diagnosing and staging intermediate- to high-risk prostate cancer.
9.Clinical analysis of robotic bilateral modified radical neck dissection through the bilateral axillo-breast approach for thyroid carcinoma
Lanqing CHEN ; Xiaolei LI ; Dayong ZHUANG ; Peng ZHOU ; Tao YUE ; Jing XU ; Sijuan CHEN ; Chenyu LI ; Changxiu SHAO ; Qingqing HE
Chinese Journal of Endocrine Surgery 2024;18(1):21-25
Objective:To research the efficacy and safety of robotic thyroidectomy and bilateral modified radical neck dissection through bilateral axillo-breast approach (BABA) .Methods:We retrospectively analyzed the clinical data of 37 patients with thyroid cancer who received bilateral modified radical neck dissection through the BABA at the Department of Thyroid and Breast Surgery of the 960th Hospital of the People’s Liberation Army from Jan. 2014 to Jan. 2023. There were 24 females and 13 males, and the average age of the patients was (33,22±10.53) years old. The tumor diameter, number of lymph node dissection and metastasis in the central and lateral regions, average operation time, average hospital stay, complications, and aesthetic score were recorded. SPSS 25.0 software was used for statistical analysis, and the measurement data was calculated using mean ± standard deviation ( ± s), and the counting data was expressed in percentages and numbers. Results:A total of 37 thyroid cancer patients underwent robotic bilateral regional lymph node dissection. The 37 patients received total thyroidectomy, bilateral central compartment and cervical lateral regional lymph node dissection. All the pathological types were papillary carcinoma, with a maximal tumor diameter of (1.47±0.85) cm. The average number of central lymph nodes dissected was 19.46±8.84, and there were (10.24±5.95) metastases; The average number of lymph nodes removed from the bilateral cervical region was 38.92±14.21, and there were (7.92±5.84) metastases. The average operation time was (288.05±77.09) min, the average length of stay in the hospital was (10.76±3.92) days, and the average length of stay in the hospital following surgery was (8.03±2.08) days. These patients had no permanent hypoparathyroidism, permanent recurrent laryngeal nerve palsy, infection, accessory nerve injury and phrenic nerve injury after operation. Transient hypoparathyroidism occurred in 15 patients, transient recurrent laryngeal nerve palsy occurred in 1 patient, and chyle leak occurred in 2 patients. One month after surgery, the aesthetic score was 9.51±0.69.Two patients were found lymph node metastases during the (27.81±15.10) months of follow-up, and received robotic cervical lymph node dissection with BABA.Conclusion:For carefully chosen thyroid cancer patients with bilateral lateral cervical region lymph node metastases, robotic bilateral cervical lymph node regional dissection via BABA is safe and feasible, and good cosmetic results can be obtained.
10.Study of standardizing nomenclatures for organs at risk of nasopharyngeal carcinoma via the contouring content-based image retrieval method
Xiuying MAI ; Shen HUANG ; Zhenfang ZHONG ; Wanjia ZHENG ; Shuxian CHEN ; Guangsen HUANG ; Su ZHOU ; Sijuan HUANG ; Yunfei XIA ; Xiaoyan HUANG ; Xin YANG
Chinese Journal of Radiation Oncology 2021;30(8):803-810
Objective:Based on the AAPM TG-263, a Content-Based Standardizing Nomenclatures (CBSN) was proposed to explore the feasibility of its standardization verification for organs at risk (OAR) of nasopharyngeal carcinoma (NPC).Methods:The radiotherapy structure files of 855 patients with nasopharyngeal carcinoma (NPC) receiving intensity-modulated radiotherapy (IMRT) from 2017 to 2019(15 of whom showed clinical anomalous structures) were retrospectively collected and processed. The Matlab self-developed software was used to obtain the image position, geometric features, first-order gray histogram, and the Gray-level Co-occurrence Matrix′s texture features of the OAR contour outlined by the doctor to establish the CBSN Location Verification model and CBSN Knowledge Library. Fisher discriminant analysis was employed to establish a CBSN OAR classification model, which was evaluated using self-validation, cross-validation, and external validation, respectively.Results:99%(69/70) of the simulated anomalous structures were outside the 90% reference range of the CBSN Knowledge Library and the characteristic parameters significantly differed among different OARs (all P<0.001). The accuracy rates of self-validation, cross-validation and external verification of the CBSN OAR classification model were 92.1%, 92.0% and 91.8%, respectively. Fourteen cases of clinical abnormal structures were successfully detected by CBSN with an accuracy rate of 93%(14/15). In the simulation test, the accuracy of the left and right location verification reached 100%, such as detecting the right eye lens named Len_L. Conclusion:CBSN can be used for OAR verification of NPC, providing reference for multi-center cooperation and standardized radiotherapy of NPC patients.