1.The clinical application on composite graft of acellular allo-dermal matrix and auto-microskin on escharectomy after deep burns.
Yun-chuan PAN ; Jia-qin XU ; Yan-kun CHEN ; Song-ling LI ; Si-huan CHEN ; Duo-neng WU ; De-bin ZENG ; Zun-hong LIANG
Chinese Journal of Surgery 2004;42(7):410-412
OBJECTIVETo present the clinical application of composite graft of acellular allo-dermis matrix (ADM) with thin auto-microskin on burn wound.
METHODS8 inpatients with 18 full thickness skin burn wounds were transplanted with allo-ADM after eschar was excised, then the auto-microskin and allo-human skin were covered on the area of the matrix, the wound where no allo-ADM grafting were covered as control groups only with auto-microskin and allo-human skin. The area of donor to wound is 1:5 - 1:8.
RESULTSSurvived rate of 18 pieces composite skin that allo-ADM with auto-microskin were grafted were 94%. After following up for 3 to 13 months, the skins of complex grifting had well elastic and smooth texture compared to auto-microskin grafted, they appeared less cicatrisation and ulceration. 3 months after operation, it was indicated by histological examination that tightknit the epithelial-dermal conjunction and epidermal papilla structure could be identified in the allo-ADM skin and there were orderly collagenous fibres, but scar skin structure was observed in that auto-microskin grifted area.
CONCLUSIONThe graft effectiveness of allo-ADM and auto-microskin was better than that of auto-microskin, and this method could be used on major deep burn wound healing.
Adult ; Burns ; surgery ; Female ; Humans ; Male ; Middle Aged ; Skin Transplantation ; methods ; Tissue Donors ; Transplantation, Autologous ; Transplantation, Homologous ; Treatment Outcome
2.Miniature Non-invasive Blood Pressure Measurement and Verification System.
Hang-Duo NIU ; Si-Nian YUAN ; Zi-Fu ZHU ; Ji-Lun YE ; Xu ZHANG ; Hui YU
Chinese Journal of Medical Instrumentation 2022;46(3):278-282
Mercury sphygmomanometer based on traditional auscultation method is widely used in primary medical institutions in China, but a large amount of blood pressure data can not be directly recorded and applied in scientific research analysis, meanwhile auscultation data is the clinical standard to verify the accuracy of non-invasive electronic sphygmomanometer. Focusing on this, we designed a miniature non-invasive blood pressure measurement and verification system, which can assist doctors to record blood pressure data automatically during the process of auscultation. Through the data playback function,the software of this system can evaluate and verify the blood pressure algorithm of oscillographic method, and then continuously modify the algorithm to improve the measurement accuracy. This study introduces the hardware selection and software design process in detail. The test results show that the system meets the requirements of relevant standards and has a good application prospect.
Auscultation
;
Blood Pressure/physiology*
;
Blood Pressure Determination
;
Oscillometry
;
Sphygmomanometers
4.An Adaptive Method for Detecting and Removing EEG Noise.
Si-Nian YUAN ; Ruo-Wei LI ; Zi-Fu ZHU ; Sheng-Cai MA ; Hang-Duo NIU ; Ji-Lun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2022;46(3):248-253
To solve the problem of real-time detection and removal of EEG signal noise in anesthesia depth monitoring, we proposed an adaptive EEG signal noise detection and removal method. This method uses discrete wavelet transform to extract the low-frequency energy and high-frequency energy of a segment of EEG signals, and sets two sets of thresholds for the low-frequency band and high-frequency band of the EEG signal. These two sets of thresholds can be updated adaptively according to the energy situation of the most recent EEG signal. Finally, we judge the level of signal interference according to the range of low-frequency energy and high-frequency energy, and perform corresponding denoising processing. The results show that the method can more accurately detect and remove the noise interference in the EEG signal, and improve the stability of the calculated characteristic parameters.
Algorithms
;
Electroencephalography
;
Signal Processing, Computer-Assisted
;
Signal-To-Noise Ratio
;
Wavelet Analysis
5.E17110 promotes reverse cholesterol transport with liver X receptor β agonist activity in vitro.
Ni LI ; Xiao WANG ; Peng LIU ; Duo LU ; Wei JIANG ; Yanni XU ; Shuyi SI
Acta Pharmaceutica Sinica B 2016;6(3):198-204
Liver X receptor (LXR) plays an important role in reverse cholesterol transport (RCT), and activation of LXR could reduce atherosclerosis. In the present study we used a cell-based screening method to identify new potential LXRβ agonists. A novel benzofuran-2-carboxylate derivative was identified with LXRβ agonist activity: E17110 showed a significant activation effect on LXRβ with an EC50 value of 0.72 μmol/L. E17110 also increased the expression of ATP-binding cassette transporter A1 (ABCA1) and G1 (ABCG1) in RAW264.7 macrophages. Moreover, E17110 significantly reduced cellular lipid accumulation and promoted cholesterol efflux in RAW264.7 macrophages. Interestingly, we found that the key amino acids in the LXRβ ligand-binding domain had distinct interactions with E17110 as compared to TO901317. These results suggest that E17110 was identified as a novel compound with LXRβ agonist activity in vitro via screening, and could be developed as a potential anti-atherosclerotic lead compound.