2.Comparison of bispectral index-guided endoscopic ultrasonography with continuous vs. intermittent infusion of propofol: a retrospective study in Japan
Ayana OKAMOTO ; Ken KAMATA ; Tomohiro YAMAZAKI ; Shunsuke OMOTO ; Kosuke MINAGA ; Mamoru TAKENAKA ; Masatoshi KUDO
Clinical Endoscopy 2024;57(6):814-820
Background/Aims:
This study aimed to evaluate the safety and efficacy of continuous propofol infusion for anesthesia during endoscopic ultrasonography (EUS).
Methods:
A total of 427 consecutive patients who underwent EUS between May 2018 and February 2019 were enrolled in this study. The patients were divided into two propofol infusion groups: continuous (n=207) and intermittent (n=220). The following parameters were compared: (1) propofol dose, (2) respiratory and circulatory depression, (3) body movement requiring discontinuation of the examination, (4) awakening score, and (5) patient satisfaction.
Results:
The median total maintenance dose of propofol was significantly higher in the continuous group than in the intermittent group (160.0 mg vs. 130.0 mg, respectively); however, the reduction in SpO2 was significantly lower in the continuous group (2.9% vs. 13.2%). Body movements occurred less frequently in the continuous group than in the intermittent group (40.1% vs. 49.5%, respectively). The rate of complete awakening was significantly higher in the continuous group than in the intermittent group. Finally, there was a significant difference in the percentage of patients who answered “absolutely yes” when asked about receiving EUS again: 52.7% in the continuous group vs. 34.3% in the intermittent group.
Conclusions
Continuous infusion resulted in stable sedation and reduced propofol-associated risks.
3.Comparison of bispectral index-guided endoscopic ultrasonography with continuous vs. intermittent infusion of propofol: a retrospective study in Japan
Ayana OKAMOTO ; Ken KAMATA ; Tomohiro YAMAZAKI ; Shunsuke OMOTO ; Kosuke MINAGA ; Mamoru TAKENAKA ; Masatoshi KUDO
Clinical Endoscopy 2024;57(6):814-820
Background/Aims:
This study aimed to evaluate the safety and efficacy of continuous propofol infusion for anesthesia during endoscopic ultrasonography (EUS).
Methods:
A total of 427 consecutive patients who underwent EUS between May 2018 and February 2019 were enrolled in this study. The patients were divided into two propofol infusion groups: continuous (n=207) and intermittent (n=220). The following parameters were compared: (1) propofol dose, (2) respiratory and circulatory depression, (3) body movement requiring discontinuation of the examination, (4) awakening score, and (5) patient satisfaction.
Results:
The median total maintenance dose of propofol was significantly higher in the continuous group than in the intermittent group (160.0 mg vs. 130.0 mg, respectively); however, the reduction in SpO2 was significantly lower in the continuous group (2.9% vs. 13.2%). Body movements occurred less frequently in the continuous group than in the intermittent group (40.1% vs. 49.5%, respectively). The rate of complete awakening was significantly higher in the continuous group than in the intermittent group. Finally, there was a significant difference in the percentage of patients who answered “absolutely yes” when asked about receiving EUS again: 52.7% in the continuous group vs. 34.3% in the intermittent group.
Conclusions
Continuous infusion resulted in stable sedation and reduced propofol-associated risks.
4.Comparison of bispectral index-guided endoscopic ultrasonography with continuous vs. intermittent infusion of propofol: a retrospective study in Japan
Ayana OKAMOTO ; Ken KAMATA ; Tomohiro YAMAZAKI ; Shunsuke OMOTO ; Kosuke MINAGA ; Mamoru TAKENAKA ; Masatoshi KUDO
Clinical Endoscopy 2024;57(6):814-820
Background/Aims:
This study aimed to evaluate the safety and efficacy of continuous propofol infusion for anesthesia during endoscopic ultrasonography (EUS).
Methods:
A total of 427 consecutive patients who underwent EUS between May 2018 and February 2019 were enrolled in this study. The patients were divided into two propofol infusion groups: continuous (n=207) and intermittent (n=220). The following parameters were compared: (1) propofol dose, (2) respiratory and circulatory depression, (3) body movement requiring discontinuation of the examination, (4) awakening score, and (5) patient satisfaction.
Results:
The median total maintenance dose of propofol was significantly higher in the continuous group than in the intermittent group (160.0 mg vs. 130.0 mg, respectively); however, the reduction in SpO2 was significantly lower in the continuous group (2.9% vs. 13.2%). Body movements occurred less frequently in the continuous group than in the intermittent group (40.1% vs. 49.5%, respectively). The rate of complete awakening was significantly higher in the continuous group than in the intermittent group. Finally, there was a significant difference in the percentage of patients who answered “absolutely yes” when asked about receiving EUS again: 52.7% in the continuous group vs. 34.3% in the intermittent group.
Conclusions
Continuous infusion resulted in stable sedation and reduced propofol-associated risks.
5.New endoscopic ultrasonography techniques for pancreaticobiliary diseases.
Ken KAMATA ; Masayuki KITANO ; Shunsuke OMOTO ; Kumpei KADOSAKA ; Takeshi MIYATA ; Kosuke MINAGA ; Kentaro YAMAO ; Hajime IMAI ; Masatoshi KUDO
Ultrasonography 2016;35(3):169-179
Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS. EUS-guided fine needle aspiration (EUS-FNA) has been used for diagnosing pancreatic tumors. In order to improve the histological diagnostic yield, a EUS-FNA needle with a core trap has recently been developed. Contrast-enhanced harmonic EUS is a new imaging modality that uses an ultrasonographic contrast agent to visualize blood flow in fine vessels. This technique is useful in the diagnosis of pancreatic solid lesions and in confirming the presence of vascularity in mural nodules for cystic lesions. EUS elastography analyzes several different variables to measure tissue elasticity, color patterns, and strain ratio, using analytical techniques such as hue-histogram analysis, and artificial neural networks, which are useful for the diagnosis of chronic pancreatitis and pancreatic cancer.
Biliary Tract
;
Biopsy, Fine-Needle
;
Diagnosis
;
Diagnosis, Differential
;
Elasticity
;
Elasticity Imaging Techniques
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration
;
Endosonography*
;
Needles
;
Pancreas
;
Pancreatic Neoplasms
;
Pancreatitis, Chronic
6.Bispectral index-guided propofol sedation during endoscopic ultrasonography
Ayana OKAMOTO ; Ken KAMATA ; Takeshi MIYATA ; Tomoe YOSHIKAWA ; Rei ISHIKAWA ; Tomohiro YAMAZAKI ; Atsushi NAKAI ; Shunsuke OMOTO ; Kosuke MINAGA ; Kentaro YAMAO ; Mamoru TAKENAKA ; Yasutaka CHIBA ; Toshiharu SAKURAI ; Naoshi NISHIDA ; Masayuki KITANO ; Masatoshi KUDO
Clinical Endoscopy 2022;55(4):558-563
Background/Aims:
Bispectral index (BIS) monitors process and display electroencephalographic data are used to assess the depth of anesthesia. This study retrospectively evaluated the usefulness of BIS monitoring during endoscopic ultrasonography (EUS).
Methods:
This study included 725 consecutive patients who underwent EUS under sedation with propofol. BIS monitoring was used in 364 patients and was not used in 361. The following parameters were evaluated: (1) median dose of propofol; (2) respiratory and circulatory depression; (3) occurrence of body movements; (4) awakening score >8 at the time; and (5) awakening score 2 hours after leaving the endoscopy room.
Results:
The BIS group received a significantly lower median dose of propofol than the non-BIS group (159.2 mg vs. 167.5 mg; p=0.015) in all age groups. For patients aged ≥75 years, the reduction in heart rate was significantly lower in the BIS group than in the non-BIS group (1.2% vs. 9.1%; p=0.023). Moreover, the occurrence of body movements was markedly lower in the BIS group than in the non-BIS group (8.5% vs. 39.4%; p<0.001).
Conclusions
During EUS examination, BIS monitoring is useful for maintaining a constant depth of anesthesia, especially in patients 75 years of age or older.