1.Initial Study of Diagnostic Value of Diffusion Weighted Imaging in Pancreatic Cancer
Yamin LI ; Shunlin GUO ; Junqiang LEI
Journal of Practical Radiology 2001;0(08):-
Objective To evaluate the value of diffusion weighted imaging (DWI) and apparent diffusion coefficient(ADC) in diagnosing pancreatic carcinoma. Methods DWI was performed in 25 cases of pancreatic cancer, confirmed by pathology, and 20 normal persons. Five sequences of echo planar diffusion imaging were used, b value (?10-3s/mm2 ) was 50, 100, 300, 500, and 700 respectively. Then the ADC values in tumor area, non-tumor area and normal pancreatic area were calculated.Results ADC values of tumor tissue were significantly different from that of the tissue in the same pancreas, when b value were 100 and 300 s/mm2; there was statistically significantly difference between tumor group and normal group when b value were 100, 300, 500 and 700 s/mm2. ADC values of the tissue except for tumor tissue in the same pancreas were significant different from that of normal group when b value were 500 and 700 s/mm2. Conclusion DWI is a rapid and feasible method in detecting pancreatic cancer.
2.Clinical Application of 64-slice CT Perfusion Imaging in Hepatic Metastases
Yuli WANG ; Shunlin GUO ; Jigang GUO ; Baozhi YANG
Journal of Practical Radiology 2001;0(08):-
Objective To study 64-slice CT perfusion features of metastatic tumors of liver and its clinical value.Methods 23 cases (40 lesions) with liver metastases underwent CT perfusion scanning.Hepatic arterial perfusion index(HPI) parameters including blood flow perfusion(BF),patlak blood capacity (pBV),vascular permeability (P,permeability),arterial liver perfusion(ALP),portal venous perfusion( PVP ) were analyzed in comparison with that of normal liver .Results (1)BF, pBV , P , ALP , PVP and HPI in normal liver tissue were (47.85?8.11) ml?100ml-1?min-1,41.25?6.32 (1000:1), 64.25?11.10 (0.5 ml?100ml-1?min-1),(24.55?2.96) ml?100ml-1?min-1, (105.24?16.42) ml?100ml-1?min-1,(20.18?3.81),respectively.(2)BF,pBV,P,ALP and PVP between the normal hepatic tissue and the centre of lesions were of statistically significance (P
3.CT perfusion imaging for predicting tiny lymph nodes metastasis of squamous cell carcinoma in cervix after neoadjuvant chemotherapy
Liang YIN ; Junqiang LEI ; Shunlin GUO ; Yanan ZHAI ; Qihong GUO
Chinese Journal of Medical Imaging Technology 2017;33(3):428-432
Objective To explore the application value of CT perfusion imaging for predicting the tiny lymph nodes metastasis and micrometastasis of squamous cell carcinoma in cervix after neoadjuvant chemotherapy.Methods The clinical data and CT perfusion parameters of 46 patients with cervical squamous cell carcinoma who underwent neoadjuvant chemotherapy followed by surgery were enrolled in the study.Based on the surgical pathology findings and short-term follow up,the cases were divided into without tiny lymph nodes metastasis (short axle diameter of lymph nodes<10 mm) group (n=32) and with tiny lymph nodes metastasis group (n=14).All perfusion data were analyzed retrospectively and the diagnostic value were investigated.Results Blood flow (BF),blood volume (BV) and the maximum diameter of tumor per-chemotherapy in with tiny lymph nodes metastasis group were higher than those in without tiny lymph nodes metastasis group (all P<0.05).The differences of the maximum diameter of tumor after chemotherapy,permeability,time to peak (TTP) between two groups were not statistically significant (all P>0.05).Multivariate Logistic regression analysis showed BF and the maximum diameter of tumor per-chemotherapy were independent predictors of the tiny lymph nodes metastasis in cervix after neoadjuvant chemotherapy.ROC showed BF (AUC=0.86,P<0.001,95%CI [0.75,0.96]) had higher predictive value than maximum diameter of tumor per-chemotherapy (AUC=0.70,P=0.02,95 % CI [0.54,0.88]).Conclusion CT perfusion imaging shows the significant predictive value for the tiny lymph nodes metastasis of squamous cell carcinoma in cervix after neoadjuvant chemotherapy.
4.Appearances of decussation of superior cerebellar peduncle in DTT FACT with different reconstruct parameters
Yu DOU ; Hongbin HAN ; Shunlin GUO ; Junqiang LEI
Chinese Journal of Medical Imaging Technology 2010;26(4):752-755
Objective To observe the appearances of decussation of superior cerebellar peduncle (SCP) on MR diffusion tensor imaging (DTI) with different parameters of scanning and reconstruction. Methods Twenty healthy volunteers were examined on Siemens 3.0T MR DTI (b=0, 1000 s/mm~2), post processing were made in Siemens Leonardo workstation using Siemens Standar 6 dirs software to reconstruct the white matter fibers with different fractional anisotropy (FA) threshold value (0.04-0.20), angle threshold value (20°-89°) and voxel size (1.2 mm×1.2 mm×3.0 mm-1.6 mm×1.6 mm×5.0 mm). Results Crossing fiber was presented each voxel group on diffusion tensor tractography (DTT). The types of crossing fiber in the small voxel were more than those of big voxel image obviously. Reduced along with the FA threshold value, the number of crossing fiber increased gradually. After the peak value (FA=0.08), the number of crossing fiber reduced along with the FA threshold value reduced gradually. Increased along with the angle threshold value, the number of crossing fiber increased gradually. The number of crossing fiber reduced along with the angle threshold value increased gradually after the peak value (the angle threshold value=80°). There were 5 kinds of MR fiber tracking appearances at the level of decussation of SCP on DTT. The fiber crossed to the opposited red nucleus in anterior-posterior style, superior-inferior style and single main bundle fiber. Kissing fiber and missing fiber sign was shouw in all subjects, which mainly located in the center of the decussation. Conclusion DTT FACT can show the descussation of SCP in most health subjects with five typical appearance. The descussation of SCP has the obvious appearances, may be causing by individual difference. For the crossing fiber of SCP, voxel size 1.2 mm×1.2 mm×3.0 mm, FA 0.08 and the angle 80° are recommended.
5.CT and MR diagnosis of hepatic hydatidosis
Junqiang LEI ; Yong CHEN ; Xiaohui WANG ; Shunlin GUO ; Xingqiang ZHANG
Chinese Journal of Medical Imaging Technology 2010;26(2):291-293
Objective To observe the CT and MR features of hepatic hydatid cyst, and to evaluate the diagnostic value of CT and MR. Methods CT and MR images were retrospectively analyzed in 42 patients with pathologically proved hepatic hydatid diseases, and the relative articles were reviewed. Results Hepatic echinococcosis granulosus occured in 85.71% patients, among which ring like pattern calcification, the ribbon calcification, multiple daughter vesicles and detached membranes within cyst were the main findings. Hepatic echinococcosis alveolaris occured in 14.29% patients, whereas the main finding included calcification, small vacuoles, peninsula sign, geographic sign and colliquative necrosis. For the diagnosis of hepatic hydatidosis, MR was better than CT in the judgement of the cyst wall, detached membranes and fibrous septum, but was inferior to CT in displaying calcification sign. Conclusion Hepatic hydatidosis can be diagnosed either with CT or MR, CT is superior to MR in integrated diagnosis of this disease.
6.Application of dual-source CT in the diagnosis of complex congenital heart disease
Zhonghong XIN ; Shunlin GUO ; Junqiang LEI ; Yaping ZHANG
Journal of Practical Radiology 2016;32(12):1853-1855,1860
Objective To analyze the value of dual-source computed tomography (DSCT)in the diagnosis of complex congenital heart disease(CCHD).Methods DSCT angiography and transthoracic echocardiography (TTE)were retrospectively assessed in 46 patients who were confirmed by surgery with 107 deformities.Results There were 49 intracardiac deformities and 58 extracardiac deformities.The diagnostic accuracies in detection of intracardiac malformation were 81.63%(40/49)on DSCT and 93.88%(46/49) on TTE,those in detection of extracardiac malformation were 94.83%(55/58)on DSCT and 58.62%(34/58)on TTE,and the overall accuracies of cardiovascular malformations were 88.79%(95/107)on DSCT and 74.77%(80/107)on TTE,respectively,exhibting statistical differences.The diagnostic accuracy of DSCT in combination with TTE in detection of intracardiac and extracardiac malformation was 94.39%(101/107),which was higher than DSCT or TTE with statistical differences.Conclusion The combination of TTE and DSCT is helpful to improve the diagnostic accuracy of CCHD.
7.Progresses of CAIPIRINHA-Dixon-TWIST-VIBE in diagnosis of small hepatocellular carcinoma
Wenting MA ; Jinkui LI ; Ya'nan ZHAI ; Shunlin GUO ; Junqiang LEI ;
Chinese Journal of Medical Imaging Technology 2017;33(8):1277-1280
Early small hepatocellular carcinoma (SHCC) can be cured by surgery and interventional operation to improve the survival rate of paitents,so the accurate diagnosis of SHCC is of great significance.Presently,the dynamic contrast-enhanced MR scan could only obtain single arterial phase imaging by single breath hold,and it had breathing motion artifact because of the long scanning time.The early arterial transient enhancement of SHCC was easy to be misdiagnosed.The CAIPIRINHA-Dixon-TWIST-VIBE (CDT-VIBE) sequence couldobtain high-quality multiple arterial phases images and hepatic arterial dominant (HAD) images in short-time scanning.And it could not only detect small focal lesions which were difficult to find by other imaging examination,but also find the start enhanced difference between lesions which were relevant to lesions property and blood supplement.The CDT-VIBE has a high clinical value in diagnosis and treatment of SHCC.The research progresses of CDT-VIBE in diagnosis of SHCC was reviewed in this article.
8.The hemoprotective effects of a rotary magnetic field in mice exposed to irradiation
Shuzhen WEI ; Xuejun XIE ; Yuhong QI ; Guozhen GUO ; Shunlin SHAN ; Qianwen LI ; Chuang ZHANG ; Yunxiang DU
Chinese Journal of Radiological Medicine and Protection 2008;28(6):660-664
Objective To study the hemoprotective effects of a rotary magnetic field (RMF) to radiation-injured mice. Methods 132 male BALB/c mice were randomly divided into four groups: a normal group (N), a magnetic treatment group (M), an irradiation group(R) and an irradiation combining magnetic treatment group (R + M). Mice in the N group received no treatment. Mice in the R and R + M groups received total body irradiation with 6.0 Gy 60Co γ/rays. Mice in the M and R + M groups were treated with a RMF for one and half an hour at a time, twice a day, totally for 30 days. The survival rate was observed for 30 days. On days 0, 5, 9, 15, 21, 30, the subjects' peripheral blood cells were counted. On day 9, 23 and 30, the number of bone marrow nucleated cells (BMNCs), colony forming unit-spleen (CFU-S), spleen-body ratio, the cell cycle and apoptosis of bone marrow cells were measured. The pathological sectioning of the femur was performed and the expression level of bone morphogenetic proteins (BMP2/4) in the bone marrow was evaluated. Results ①No mice died in the N and M group. The RMF treatment increased the survival rate and survival days among the irradiated mice (P < 0.01). ②The RMF treatment increased the number of blood cells in their peripheral blood of the R + M group. ③The number of BMNCs, CFU-S and the proportation of G2 + M stage in the R + M were markedly higher than that of the R group, but the proportation of the apoptosis was lower than that of the R group on the 9th day (P < 0.05). Furthermore, the spleen index in the R + M group was also higher than that of the R group on the 23rd day (P < 0.05). ④RMF could improve the expression level of BMP2/4 in the radiation-injued mice. Conclusion The RMF treatment had an obvious protective effect against the effects of irradiation and it accelerated the recovery of hematopeiesis and the hematopoietic microenvironment in mouse bone marrow.
9.Mechanism involved in the apoptosis of human hepatocelluar cancer cell line HepG2 induced by proteasome inhibitor MG132
Hui HE ; Fang GUO ; Shunlin QU ; Zhong REN ; Junwen LIU ; Xiangdong YANG
Chinese Pharmacological Bulletin 2003;0(07):-
Aim To study the effect of proteasome inhibitor MG132 on expression of Caspase-3 and UPP associated genes in the apoptosis of human hepatocelluar cancer cells.Methods HepG2 cells were treated with MG132 (2,5,10 ?mol?L -1) for 24 h. The apoptotic cells were determined with flow cytometric analysis. The levels of E1, E2, E3 and Caspase-3 mRNA expression were detected with RT-PCR. Caspase-3 protein expression was detected with immunohistochemistry. Results The results showed that the increase of the degree of HepG2 cell apoptosis was concentrationly dependent. RT-PCR showed that E1, E2 and E3 gene expressions were decreased in the treatment group. MG132 down-regulated the gene expression of E1, E2, E3 and up-regulated the gene/protein expression of Caspase-3. Conclusion Proteasome inhibitor MG132 may induce HepG2 cells apoptosis by inhibitting UPP activity,up-regulating the gene/protein expression of Caspase-3.
10.Preliminary study of gastric carcinoma volume measurement using computed tomography for N staging evaluation
Nan JIANG ; Shunlin GUO ; Gang WANG ; Zhonghong XIN ; Zhongchun ZHOU ; Liang YIN ; Mei YANG ; Hao YUAN ; Ying FENG
Journal of Practical Radiology 2015;(1):87-90
Objective To evaluate the value of volume measured by multi-slice spiral CT in preoperative N staging of gastric canc-er.Methods CT data of 1 93 cases of gastric cancer proven pathologically were collected and analyzed.Volume of the tumor was cal-culated in the portal phase,and the correlation between the results and N staging was evaluated.ROC curve was used to get diagnos-tic value to differentiate N stages.Results Intra-observer Kappa value was 0.77 (P < 0.05 ),0.72 (P < 0.05 ),Inter-observer Kappa value was 0.69 (P <0.05).The tumor volume data was positively correlated with different N stages (r=0.568,P <0.05). ROC curve showed that the volume could help differentiate between stage N0 and stage N1 - N3 (cutoff 12.06 cm3 ,sensitivity 55%,specificity 95%),stage N0-N1 and stage N2-N3 (cutoff 22.35 cm3 ,sensitivity 66%,specificity 86%),stage N0-N2 and stage N3 (cutoff 25.95 cm3 ,sensitivity 62%,specificity 89%)respectively.Conclusion The volume of gastric cancer measured by CT plays an important part in predicting lymph node metastasis staging and optimizing individualized clinical strategy for patients.