1.Endoscopic balloon dilation combined with brush cytology in diagnosis of ductal cholangiocarcinoma
Pingxiao HUANG ; Qilong SONG ; Shujie DI ; Yan FAN ; Jian WANG ; Yusheng LIAO ; Heng ZHANG ; Jie WU
Chinese Journal of Hepatobiliary Surgery 2021;27(3):202-205
Objective:To study the combined use of endoscopic balloon dilation with endoscopic biliary brushings in diagnosis of bile duct strictures.Methods:A prospective single center study was conducted at the Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology. All patients with suspected malignant bile duct strictures shown on CT or MRI imaging from January 2018 to January 2020 were reviewed. All patients gave informed consent to the endascopic retrograde cholangiopancreatography procedures. Their clinical and follow-up data were analyzed. All patients underwent endoscopic balloon dilation of bile duct strictures. Before and after balloon dilation, biliary brush cytology was performed, and the results were used to classify the patients into the control group and the experimental group. Pathological examination of the brush cytology samples was carried out by a single chief pathologist. Presence of cancer cells or significant heterogeneous cells indicated a positive brush cytology test. Negative patients who still highly consider cholangiocarcinoma and agree to surgery and whose gross specimen is confirmed to be malignant after surgery should be considered as false negative by brush examination; it is difficult to judge that patients with cholangiocarcinoma have progress after 2 months of follow-up should be considered as false negative by brush examination. Any progression of disease indicated that the brush test was wrong and the test was again classified as false negative. Only when there was no progression of strictures was the possibility of a benign biliary stricture being considered. The advantage test (McNemar test) was used to analyze the difference between the two diagnostic methods.Results:Of 39 patients who were included in this study, there were 26 males and 13 females, with an age of (68.0 ± 5.2) years. Cholangiocarcinoma was diagnosed by histopathology, surgery or at 2 months follow-up in 35 patients. In the control group, 17 patients had a positive brush test (sensitivity rate was 48.6%, 17/35). In the experimental group, 26 patients had a positive brush test (sensitivity rate was 74.2%, 26/35). In addition, 2 patients in the control group had a positive brush test, while in the experimental group, a negative brush test. A total of 28 patients were positive in the two groups. The sensitivity rate of the brush test was 80.0% (28/35). There were significant differences between the two groups ( P<0.05). Conclusion:Endoscopic balloon dilation combined with endoscopic biliary brushings improved the sensitivity of pathological diagnosis of cholangiocarcinoma, and endoscopic biliary brushings before and after balloon dilation improved the sensitivity of diagnosis.
2.Review and reflection on the development of health technology innovation and achievement transformation in China
Di WU ; Shujie LIAO ; Jiayi WANG ; Kaili ZHAO
Chinese Journal of Hospital Administration 2023;39(4):299-303
Technological innovation and achievement transformation are the key to the organic combination of innovation-driven development strategy and high-quality health development, and play an important role in comprehensively promoting the construction of " healthy China". The author made a comprehensive analysis of the practice of scientific and technological innovation and achievement transformation in health care over the past 40 years of reform and opening up, and summarized the various stages based on the time dimension. On this basis, the author analyzed the opportunities and challenges faced by technological innovation and achievement transformation in health care, and put forward development suggestions.
3.Long TR three-dimensional inversion recovery sequence with real reconstruction(3D real IR)for quantifying inner ear endolymphatic hydrops
Di WU ; Menglong ZHAO ; Mengsu ZENG ; Kai LIU ; Shujie ZHANG ; Wei SUN
Chinese Journal of Medical Imaging Technology 2024;40(8):1174-1178
Objective To observe the value of long TR three-dimensional inversion recovery sequence with real reconstruction(3D real IR)for quantifying inner ear endolymphatic hydrops(EH).Methods Totally 46 Ménière's disease(MD)patients and 21 healthy volunteers were prospectively enrolled.MR scanning for inner ear based on 3D real IR and 3D fluid attenuated inversion recovery(3D FLAIR)sequence 4-6 h after administration of contrast agents were performed.The imaging qualities were scored and compared between groups.The endolymphatic space area and the membranous labyrinth area of cochlea and vestibule,as well as endolymph/membranous labyrinth area percentage were calculated,the present or not of EH and the grade of EH were evaluated.EH inner ears of MD patients were enrolled in EH group,while inner ears of healthy volunteers were taken as controls(control group).The endolymphatic space area,membranous labyrinth area and endolymph/membranous labyrinth area percentage of cochlea and vestibule were compared between groups.The receiver operating characteristic(ROC)curve was drawn to calculate the diagnostic efficacy of the above indexes.Results Cochlear and/or vestibular EH were detected in 56 ears,including cochlear EH in 52 ears and vestibular EH in 45 ears among 46 MD patients(EH group),but not in 42 ears in control group.The subjective quality scores of 3D real IR images were higher than those of 3D-FLAIR(both P<0.05).Quantitative analysis based on 3D real IR images revealed that,compared with control group,significantly larger endolymph areas and endolymph/membranous labyrinth area percentages in both cochlea and vestibule were found in EH group(all P<0.001).The area under the curve(AUC)of cochlear or vestibular endolymph/membranous labyrinth area percentage for identifying inner ear EH was 0.999 and 0.985,respectively.Taken 13.64%and 24.13%as the critical value of cochlear or vestibular endolymph,the specificity was 100%and 92.86%,respectively,and the sensitivity was 96.43%and 96.43%,respectively.Conclusion MR long TR 3D real IR was helpful to quantifying inner ear EH.
4.Alteration of cognitive function in overweight and obese adolescents and its relationship with serum FGF21 levels
Rui HAN ; Qian WU ; Dan LIU ; Di CHENG ; Ying ZHANG ; Jiacheng NI ; Piao KANG ; Anran CHEN ; Shujie YU ; Qichen FANG ; Huating LI
Journal of Shanghai Jiaotong University(Medical Science) 2024;44(1):87-97
Objective·To evaluate the changes in cognitive function in overweight and obese adolescents,and explore the association between cognitive function and fibroblast growth factor 21(FGF21).Methods·A total of 175 adolescents from a senior high school in Shanghai were divided into normal weight group(n=50),overweight group(n=50)and obese group(n=75)based on their body mass index(BMI).General information,anthropometric data and laboratory testing indicators of the adolescents were collected and compared.The cognitive function of the three groups of adolescents was assessed by using the accuracy(ACC)and reaction time of Flanker task and n-back task.Enzyme-linked immunosorbent assay(ELISA)was used to detect the serum FGF21 level of the three groups of adolescents.Partial correlation analysis and multiple linear regression model were used to evaluate the correlation between cognitive task performance and anthropometric data and laboratory testing indicators.Results·Compared with the normal weight group,systolic blood pressure,diastolic blood pressure,and the levels of fasting plasma glucose,glycosylated hemoglobin and triacylglycerol in the obese group were higher(all P<0.05).Under congruent or incongruent stimulus conditions in the Flanker task,there was no significant difference in ACC between any two groups;compared with the normal weight and overweight groups,the reaction time of the adolescents in the obese group was prolonged(all P<0.05).In the n-back task,there were no significant differences in ACC between any two groups,while the obese group had longer reaction time in the 1-back and 2-back tasks compared to the normal weight and overweight groups(all P<0.05).Compared with the normal weight group,serum FGF21 levels of the adolescents in the obese group were higher(P=0.000).Partial correlation analysis showed that the reaction time of the adolescents in Flanker and n-back tasks was correlated with their BMI,body fat mass,waist circumference,waist-to-hip ratio and FGF21 level(all P<0.05).Multiple linear regression analysis further confirmed that BMI was associated with prolonged reaction time in cognitive-related behavioral tasks in the adolescents(all P<0.05),and FGF21 level was associated with ACC in the 2-back task(P=0.000)and reaction time in the incongruent stimulus condition(P=0.048).Conclusion·Overweight and obese adolescents have cognitive impairments,and BMI and serum FGF21 levels are associated with changes in their cognitive function.
5.Application of three-dimensional fluid-attenuated inversion recovery sequence using artificial intelligence-assisted compressed sensing technique in intravenous gadolinium contrast-enhanced magnetic resonance imaging of inner ear
Kai LIU ; Jian WANG ; Huaili JIANG ; Shujie ZHANG ; Di WU ; Xinsheng HUANG ; Mengsu ZENG ; Menglong ZHAO
Chinese Journal of Clinical Medicine 2025;32(2):212-217
Objective To investigate the value of artificial intelligence-assisted compressed sensing (ACS) technology for intravenous gadolinium contrast-enhanced magnetic resonance imaging of the inner ear using three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence. Methods The patients received gadolinium contrast-enhanced magnetic resonance imaging using ACS and united compressed sensing (uCS) 3D-FLAIR at Zhongshan Hospital, Fudan University from January to November 2024 were prospectively enrolled. The repetition time was 16 000 ms, and acquisition time was 6 min 40 s and 10 min 24 s in ACS 3D-FLAIR and uCS 3D-FLAIR, respectively. The images on the two sequences were evaluated independently by two radiologists. The image quality of the two sequences was subjectively evaluated and compared. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between the two sequences. The grading consistencies using two sequences and between the two doctors were analyzed. Results There was no statistically difference in subjective score of image quality between the two sequences. SNR and CNR of the ACS 3D-FLAIR sequence were significantly higher than those of the uCS 3D-FLAIR sequence (P<0.001). The kappa values of grades of cochlear and vestibular endolymphatic hydrops were 0.942 and 0.888 using two sequences (P<0.001). The kappa values of grades of cochlear and vestibular endolymphatic hydrops using the ACS 3D-FLAIR sequence between the two doctors were 0.784 and 0.831, respectively (P<0.001); the kappa values of grades of cochlear and vestibular endolymphatic hydrops using uCS 3D-FLAIR sequence between the two doctors were 0.725 and 0.756, respectively (P<0.001). Conclusions ACS 3D-FLAIR could provide higher SNR and CNR than uCS 3D-FLAIR, and is more suitable for intravenous gadolinium contrast-enhanced magnetic resonance imaging of the inner ear; the endolymphatic hydrops grades using ACS 3D-FLAIR is similar to use uCS 3D-FLAIR.
6.Value of three-dimensional inversion-recovery with real reconstruction sequence using an ultralong repetition time for endolymphatic hydrops
Menglong ZHAO ; Huaili JIANG ; Shujie ZHANG ; Zhuang LIU ; Kai LIU ; Di WU ; Xinsheng HUANG ; Mengsu ZENG
Chinese Journal of Clinical Medicine 2025;32(2):200-206
Objective To evaluate the value of an optimized three-dimensional inversion-recovery with real reconstruction (3D-real IR) sequence with a longer repetition time (TR, 16 000 ms) based on modulated flip angle technique in refocused imaging with extended echo train (MATRIX) in the endolymphatic hydrops (EH) imaging after intratympanic gadolinium (Gd) administration, and to compare it with a conventional 3D-real IR based on the turbo spin echo (TSE) sequence. Methods From July 2021 to November 2022, twenty-seven patients received both the conventional and optimized 3D-real IR sequences after bilateral intratympanic Gd administration. Images of the two sequences were qualitativly evaluated and compared. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and area ratio of endolymph against the total lymphatic space from the two sequences were measured and compared. Results 14(25.9%) ears with insufficient contrast for the EH diagnosis on the conventional sequence were clearly displayed on the optimized sequence. Image score, CNR and SNR of the optimized sequence were significantly higher than those of the conventional sequence (P < 0.001). The scanning time of two sequences was similar. The area ratio of endolymph against the total lymphatic space in the cochlear was significantly higher on the conventional 3D-real IR than that on the optimized 3D-real IR (P < 0.001); there was no statistical difference in the vestibule between the two sequences. Conclusions Compared with conventional sequence, optimized 3D-real IR sequence with a longer TR may be better for evaluation of EH after intratympanic Gd administration.