1.Applied technology improving bio-compatibility of hemodialysis membrane
Changjun HOU ; Shujia ZHENG ; Danqun HUO ; Wenbin ZHANG ; Yuanliang WANG
Chinese Medical Equipment Journal 1993;0(05):-
As a means to substitute the function of kidney, hemodialysis therapy has been applied to clinical therapy. The bio-compatibility of dialyser, which is the key of part of artificial kidney, is a determining factor for the therapy. This paper describes dialyser and the methods of improving bio-compatibility of dialyser.
2.Comparison of therapeutic effect between regular spherical CRT and dual axis CRT on myopia with corneal astigmatism
Bo LIU ; Shujia HUO ; Li CHEN ; Sujun ZHOU ; Jie XIONG
Chinese Journal of Experimental Ophthalmology 2021;39(6):538-542
Objective:To compare the therapeutic effect between regular spherical corneal refractive therapy (CRT) and dual axis CRT on myopia with corneal astigmatism.Methods:A non-randomized controlled study was conducted.Aged 8 to 14 years old, forty-eight patients (48 eyes) wearing CRT orthokeratology enrolled from May, 2018 to December, 2018 in First Affiliated Hospital of Army Medical University were divided into dual axis CRT group (24 eyes) and spherical CRT group (24 eyes) according to their guardians' willingness.After 1-year follow-up, the visual acuity, eccentricity distance in treatment area, annual axial growth and the corneal punctate staining incidence of the two groups were compared.The study followed the Declaration of Helsinki, and was approved by an Ethics Committee of First Affiliated Hospital of Army Medical University (No.KY201975). Written informed consent was obtained from guardians prior to any examination.Results:The uncorrected visual acuity of the dual axis CRT group was better than that of the spherical CRT group at one week and one month after correction, and the differences were statistically significant (both at P<0.05), and there was no significant difference in uncorrected visual acuity between the two groups at other time points (all at P>0.05). The deviations of optical center in the spherical CRT group at each observation time points were significantly larger than that in the dual axis group (all at P<0.05), and the deviation was not obviously changed with time in both groups and there was no significant difference in deviation change between the two groups ( Ftime=2.301, P=0.074). The eccentricity was mainly in horizontal direction in spherical CRT group.The median annual axial growth was 0.12 (0.10, 0.45)mm in the dual axis CRT group and 0.14 (0.10, 0.46)mm in the spherical CRT group, with no significant difference between the two groups ( Z=0.248, P=0.804). There was 4.2%(1/24) of the patients having grade Ⅲ-Ⅳ corneal punctate staining in the dual axis CRT group, and 25.0%(6/24) in the regular spherical CRT group, showing significant difference between the two groups ( χ2=4.180, P=0.049). Conclusions:For the treatment of myopia with astigmatism, dual axis CRT shows better centricity and safety than spherical CRT.
3.Study on all-round evaluation of biocompatibility of biomaterial.
Danqun HUO ; Dongni ZHAN ; Changjun HOU ; Wenbing ZHANG ; Shujia ZHENG ; Yanrong REN ; Bingcan CHEN
Journal of Biomedical Engineering 2006;23(6):1350-1354
Biocompatibility has always been the focal point in the study of biomaterials applied to medical apparatus. But at present, the standard system hasn't formed completely to evaluate the biomaterials. In recent years scientists tend to use general standard of evaluation. In this article, based on the recalcification time, the adhesion of platelets as well as the total quantity of plasma protein and some other evidences, combining with the Analytic hierarchy process (AHP), the method of general evaluation on the biocompatibility of anticoagulant biomaterials was discussed.
Anticoagulants
;
analysis
;
Biocompatible Materials
;
standards
;
Blood Proteins
;
analysis
;
Humans
;
Materials Testing
;
methods
;
standards
;
Platelet Adhesiveness
;
drug effects