1.Adobe Photoshop images software in the verification of radiation portal
Xiaohu WANG ; Zhiqiang LIU ; Xiyi WEI ; Yong QI ; Shuigen OUYANG
Chinese Journal of Radiation Oncology 2010;19(1):53-55
Objective To investigate the value of Adobe Photashop images software in the verifica-tion of radiation portal. Methods The portal and simulation films or CT reconstruction images were impor-ted into computer using a scanner. The image size, gray scale and contrast scale were adjusted with Adobe Photoshop images software, then image registration and measurement were completed. Results By the com-parison between portal image and simulation image, the set-up errors in right-left, superior-inferior and ante-rior-posterior directions were (1.11 ± 1.37) mm, (1.33 ± 1.25) mm and (0.83±0.79) mm in the head and neck;(1.44±1.03) mm,(1.6±1.52) mm and (1.34±1.17) mm in the thorax;(1.53±0.86) mm, (1.83 ± 1.19) mm and (1.67 ± 0.68)mm in the abdomen; (1.93 ± I. 83) mm, (1.59 ± 1.07)mm and (0.85 ± 0.72)mm in the pelvic cavity. Conclusions Accurate radiation portal verification and posi-tion measurement can be completed by using Adobe Photoshop, which is a simple, safe and reliable method.
2.MR image registration based on an improved maximum mutual information.
Ling WANG ; Zhen CHEN ; Shuigen WEI ; Jing HUANG
Journal of Biomedical Engineering 2012;29(2):201-205
Medical image registration is a key step of image processing and analysis and the first problem of medical image fusion to be solved. In this paper, we focus on magnetic resonance images registration for preoperative and postoperative of deep brain stimulation for the Parkinson's disease. First of all, mutual distance is brought into the mutual information in this paper, realize the two groups of MR slices (for both preoperative and postoperative) mapping, and then 3D images are reconstructed from the corresponding MR slices. Finally, we use Powell algorithm to register 3D images. After the 3D images is registered, we can analyze the relative position between planted electrode (postoperative) and the subthalamic nucleus (preoperative), and measure the quality of deep brain stimulation scientifically.
Algorithms
;
Deep Brain Stimulation
;
methods
;
Electric Stimulation
;
Humans
;
Image Processing, Computer-Assisted
;
methods
;
Imaging, Three-Dimensional
;
Magnetic Resonance Imaging
;
methods
;
Parkinson Disease
;
pathology
;
therapy
;
Subthalamic Nucleus
;
pathology
3.Evaluation on urodynamics of the partial bladder outlet obstruction model
Jun GONG ; Wen CHENG ; Jianping GAO ; Zhengyu ZHANG ; Jinping GE ; Shuigen ZHOU ; Wenquan ZHOU ; Hongqing MA ; Wu WEI ; Song XUE ; Zhenyu XU ; Dong WANG ; Song XU
Journal of Medical Postgraduates 2003;0(07):-
Objective: To establish a rabbit unstable bladder and Partial Bladder Outlet Obstruction (BOO) model, and to study on urodynamic changes. Methods: 30 male New Zealand rabbits were divided into control group and operative group. After 8 weeks, urodynamic changes were determined after they were anaesthetized by ketamine and droperidol. Results: Prominent changes of Main urodynamic parameters were found between the operative group and control group. The incidence rate of unstable bladder was 60%. Conclusion: The method of establishing rabbit model of Partial BOO is successful. It provides a platform for the study on the changes of pathology and pathophysiology of human chronic partial BOO and treatment of this kind of diseases.
4.Multifactor analysis of bladder neck contractures after transurethral resection of prostate.
Wu WEI ; Jianping GAO ; Zhengyu ZHANG ; Jingping GE ; Hongqing MA ; Shuigen ZHOU ; Wenquan ZHOU
National Journal of Andrology 2004;10(4):287-289
OBJECTIVETo analyse different factors related to the occurrence of bladder neck contracture (BNC) and to find possible ways of reducing this complication.
METHODSAll putative factors and the numbers of BNC cases were studied with statistical analyses in 1,017 cases that had undergone transurethral resection of the prostate (TURP).
RESULTSThe morbidity of BNC after TURP was significantly higher than that of open operations. Small size of the prostate, longer time of operation, higher power in resection and prostatitis were factors of BNC.
CONCLUSIONProperties of the prostate and electrical current injuries of resection are the primary factors of BNC. The selection of patients and techniques of TURP are most important in decreasing the morbidity of BNC.
Aged ; Aged, 80 and over ; Contracture ; etiology ; prevention & control ; Humans ; Male ; Middle Aged ; Postoperative Complications ; etiology ; prevention & control ; Transurethral Resection of Prostate ; adverse effects ; Urinary Bladder
5.Effect of inter-fractional positional uncertainty on cumulative dose of target volume in intensity-modulated radiotherapy of cervical cancer
Shuigen OUYANG ; Na TAO ; Tingting LIU ; Qing GUO ; Jianqiang CHENG ; Xiyi WEI ; Fali TAO ; Ruijun NIU ; Yongwei AN
Chinese Journal of Radiation Oncology 2021;30(8):822-827
Objective:To obtain the inter-fractional set-up errors of intensity-modulated radiotherapy (IMRT) of cervical cancer by cone-beam CT (CBCT), and to analyze the variations of the set-up errors on the cumulative dose deviation of the target volume.Methods:A total of 48 patients with cervical cancer who underwent IMRT were enrolled in this study, and the set-up errors of 696 CBCTs were obtained. The set-up errors were input into the treatment planning system, and the cumulative set-up error dose was obtained by superposing the set-up errors dose. The deviation percentage was calculated by the deviation formula and the standard planning dose.Results:The set-up errors caused the offset of isocenter distance by 0.58(0.36, 0.80) cm. Different statistical differences were noted between the cumulative set-up error dose and the standard planning dose by WilCoxon test. All the dose deviations in the target volume were reduced, and the differential dose volume histogram (DVH) appeared negatively skewed, and the peak value was declined. The DVH diagram shifted to the left with an inverse S-curve and the slope was increased. The HI deviation of the target volume from small to large were: CTV 1, CTV 2, GTV/CTV, CTV 3, CTV n, CTV all, and GTV nd; The HI deviation of the target volume were increased. Conclusions:The effect of set-up errors in IMRT of cervical cancer upon the cumulative doses of the target volume significantly differs. The cumulative dose of the target volume is reduced, and the uniformity of the target volume dose becomes worse. The uncertainty of the inter-fractional position leads to an increase or decrease in the the fractional doses of the target volume. The biological effect on tumor cells and the tumor recurrence remains to be investigated. In IMRT of cervical cancer, the CBCT position calibration is required before each treatment to ensure the dose accuracy of each structure in the target volume.
6.Clinical efficacy of simple taper retentive implants in immediate posterior dental implantation for 5-7 years.
Bihui REN ; Shuigen GUO ; Yehao XU ; Jieting DAI ; Hongwu WEI
West China Journal of Stomatology 2023;41(3):341-349
OBJECTIVES:
This study aimed to evaluate the long-term clinical efficacy of simple taper retentive implants in the posterior dental area after immediate implantation for 5-7 years.
METHODS:
Selected from January 2015 to December 2017 in the Fourth Affiliated Hospital of Nanchang University dental clinic line tooth area immediately after the implant prosthesis, a total of 38 patients, 53 implants, were deep into (bone under 2 mm or higher) and the upper structure was repaired. In addition, after the completion of tracking observation of 60-90 months, the implant surrounding bone health was recorded and analyzed.
RESULTS:
After 5-7 years of follow-up, 1 of the 53 implants failed to fall out, and the implant retention rate was 98.1%. The amount of bone resorption in the proximal and distal margins 5-7 years after implant restoration was (0.16±0.94) mm and (-0.01±1.29) mm, respectively, and the difference in bone height between the proximal and distal margins of the implant and the immediate post-restoration period was not statistically significant (P>0.05). No statistically significant differences were found in the effects of periodontitis, implant site inflammation, and smoking on peri-implant marginal bone resorption (P>0.05).
CONCLUSIONS
The single taper-retained implant broadens the indications for immediate implant placement in the posterior region, and its deep sub-osseous placement (≥2 mm below the bone) avoids to a certain extent the disturbance of the implant by external stimuli and the exposure of the cervical abutment of the implant, with the good long-term stability of the marginal bone around the implant.
Humans
;
Dental Implantation, Endosseous
;
Dental Implants
;
Immediate Dental Implant Loading
;
Follow-Up Studies
;
Dental Implants, Single-Tooth
;
Alveolar Bone Loss/surgery*
;
Treatment Outcome
;
Dental Prosthesis, Implant-Supported
;
Dental Restoration Failure
7.A case of intramandibular epidermoid cyst and literature analysis.
Bihui REN ; Jieting DAI ; Yehao XU ; Shuigen GUO ; Hongwu WEI ; Weihua MAO
West China Journal of Stomatology 2023;41(4):478-482
Epidermoid cysts are generally benign neoplastic lesions, the etiology of which is unclear and is mainly related to epithelial cells left in the tissues during the embryonic period and traumatically implanted in the tissues. The most common intraosseous sites are the phalanges and the skull. Epidermoid cysts occurring in the jaws are clinically rare. In this paper, we report a case of epidermoid cyst occurring in the mandible with embedded teeth and discuss the etiology, clinical manifestations, diagnosis, and treatment of epidermoid cysts in the jaws in the context of the relevant literature.
Humans
;
Epidermal Cyst/surgery*
;
Skull
;
Mandible
;
Diagnosis, Differential
;
Epithelial Cells