1.Exploration on Morphology of Parv Interneurons and Their Distribution in Striatum in Rats
Shuhua MU ; Bingbing LIU ; Yaxi ZHU ; Keyi LI ; Wanlong LEI
Journal of Sun Yat-sen University(Medical Sciences) 2010;31(1):69-73
[Objective ] Intrastriatal Parr interneurons are considered to be the junction between striatal input and output neurons. This study purposes to confirm the morphology of Parr neurons and their distribution in striatum. [Method] Adult male SD rats were perfused and the brains were removed. The sections were conducted with a semiconductor-frozen microtome, then single labeling and double labeling were immunocytochemically conducted with PAP technique. Positive neurons were observed, counted, and calculated, and analyzed with SPSS. [Results] The distribution of Parr positive neurons in striatum was inhomogeueous, and was the most dense in the dorsal lateral area (P<0.001) ; the distribution of Parr positive neurons in matrix compartment was apparently more than patch compartment (82.0% vs 18.0%, P<0.001); Parr positive neurons in striaturn were medium-sized cell bodies with polygonal or oval in shape (mean diameter is 11.68 μm), and were larger in the lateral area than that in the medial area (P<0.01) ; the positive dendrites were dense and smooth without dendrite spines; the positive axons 1 were slender and their collaterals extended in striatum. [Conclusion] The characteristic of Parr positive neurons collecting mostly in lateral striatum and matrix eompartment, as well as their traits of intemeurons, indicated that they would affect the striatal projection neuronal function.
2.USP33 suppresses lung adenocarcinoma lung cell invasion and metastasis by down-regulating SLIT2/ROBO1 signaling pathway.
Yuhuan WANG ; Shuhua ZHANG ; Shukun MU ; Baishen ZHANG ; Shudong MA
Journal of Southern Medical University 2018;38(8):956-961
OBJECTIVETo investigate the role of USP33 as an independent prognostic marker in the regulation of SLIT2/ROBO1 signaling pathway to inhibit lung adenocarcinoma invasion and metastasis.
METHODSThe expression of USP33 in 20 lung adenocarcinoma specimens was detected by qPCR and immunohistochemistry. A549 and SPC-A-1 cells with small interfering RNA (siRNA)-mediated USP33 silencing were examined for changes in invasion and metastasis abilities using scratch assay and Matrigel assay. Western blotting was used to detect the expression of SLIT2 and ROBO1 in the cells after USP33 silencing and the expression of USP33 after interleukin-6 (IL-6) stimulation.
RESULTSqPCR and immunohistochemistry showed that USP33 was significantly decreased in lung adenocarcinoma tissues as compared with the adjacent tissues. USP33 silencing in A549 and SPC-A-1 cells significantly promoted the cell migration, invasion and metastasis and obviously down-regulated the expressions of SLIT2 and ROBO1. IL-6 stimulation of the cells obviously enhanced the expression of USP33.
CONCLUSIONSUSP33 silencing can promote the migration, invasion and metastasis of lung adenocarcinoma cells , and the mechanism may involve IL-6 and SLIT2/ROBO1 signaling pathways.
3.The role of Huaiqihuang Granules in the long-term management of bronchial asthma in young children: a multicenter real-world study
Huimin WANG ; Jinghui MU ; Chuanhe LIU ; Changshan LIU ; Ying WANG ; Zhiying HAN ; Xin SUN ; Xing CHEN ; Shuhua AN ; Dolikon MUZAPAR ; Aiping LU ; Min WANG ; Yan CHENG ; Xiaomei YIN ; Hanmin LIU ; Hong WANG ; Shan HUA ; Li DONG ; Ying HUANG ; Yi JIANG ; Jianxin XIONG ; Shenggang DING ; Wei WANG ; Shunying ZHAO ; Yuzhi CHEN
Chinese Journal of Applied Clinical Pediatrics 2023;38(4):286-290
Objective:To observe the role of Huaiqihuang Granules (HQ) in the long-term management of bronchial asthma in young children, and the effective effect on concomitant rhinitis.Methods:A prospective real-world multicenter study was conducted in children aged 2-5 years with asthma diagnosed in the outpatient department (from April 2016 to March 2019)who received either inhaled corticosteroid (ICS)/leukotriene receptor antagonist (LTRA)(control group); inhaled ICS/LTRA plus HQ(combination group), or HQ alone(HQ group). All patients were followed up at week 4, 8, 12 after treatment. The number of days with asthma symptoms, the frequency of severe asthma attacks, the level of asthma control, and the days with rhinitis symptoms in the last 4 weeks were recorded. Differences before and after treatment, and those among groups after treatment were compared using Kruskal- Wallis H test or Wilcoxon rank-sum test. Results:A total of 2 234 eligible patients were recruited, and 2 147 cases completed followed-up visits, including 477, 1 374 and 296 cases in the control group, combination group, and HQ group, respectively. After the treatment, all 3 groups showed significant declines in the days with asthma symptoms, frequency of severe asthma attack and the days with rhinitis symptoms (all P<0.01), and the rate of well-controlled asthma increased significantly ( P<0.01). It lasted until the end of follow-up. Among groups, patients in the combination group showed significantly less days of asthma symptoms than those of the other 2 group at week 8 and 12[0(0, 0.9) d vs.0(0, 0.3) d, P<0.05; 0(0, 0.1) d vs. 0(0, 1.0) d, P<0.01]. Patients in the combination group and HQ group showed a significantly lower rate of severe asthma attacks than that of the control group at week 12 [0(0, 1), 0(0, 1), 0(0, 2), all P<0.05]. The well-controlled rate of asthma in the combination group was significantly higher than that of the control group and HQ group at week 8 and 12 (89.6% vs. 85.9% vs.82.1%, H=15.28; 90.9% vs. 84.1% vs. 81.8%, χ2=29.32, all P<0.01). Conclusions:HQ can significantly alleviate symptoms of asthma and rhinitis, severe attack of asthma, and increase the control rate of asthma when used as an additional treatment or used alone.
4.Study on knowledge, attitudes and practices of pulse oximetry among pediatric healthcare providers in China and their influencing factors
Fengxia XUE ; Yuejie ZHENG ; Adong SHEN ; Hanmin LIU ; Xing CHEN ; Lili ZHONG ; Guangmin NONG ; Xin SUN ; Gen LU ; Shenggang DING ; Yuanxun FANG ; Jiahua PAN ; Zhiying HAN ; Yun SUN ; Qiang CHEN ; Yi JIANG ; Xiaoping ZHU ; Suping TANG ; Xiufang WANG ; Changshan LIU ; Shaomin REN ; Zhimin CHEN ; Deyu ZHAO ; Yong YIN ; Rongfang ZHANG ; Ming LI ; Yunxiao SHANG ; Yaping MU ; Shuhua AN ; Yangzom YESHE ; Peiru XU ; Yan XING ; Baoping XU ; Jing ZHAO ; Shi CHEN ; Wei XIANG ; Lihong LI ; Enmei LIU ; Yuxin SONG ; Yonghong YANG ; Kunling SHEN
Chinese Journal of Applied Clinical Pediatrics 2022;37(23):1807-1812
Objective:To investigate the knowledge, attitudes, and practices (KAP) of pulse oximetry among pediatric healthcare providers in China and analyze the factor influencing the KAP.Methods:A self-developed questionnaire was used for an online research on the KAP of 11 849 pediatric healthcare providers from 31 provinces, autonomous regions, and municipalities of China from March 11 to 14, 2022.The factors influencing the KAP of pulse oximetry among pediatric healthcare providers were examined by Logistic regression. Results:The scores of KAP, of pulse oximetry were 5.57±0.96, 11.24±1.25 and 11.19±4.54, respectively.The corresponding scoring rates were 69.61%, 74.95%, and 55.99%, respectively. Logistic regression results showed that the gender and working years of pediatric healthcare providers, the region they were located, and whether their medical institution was equipped with pulse oximeters were the main factors affecting the knowledge score (all P<0.05). Main factors influencing the attitude score of pediatric healthcare providers included their knowledge score, gender, educational background, working years, region, medical institution level, and whether the medical institution was equipped with pulse oximeters (all P<0.05). For the practice score, the main influencing factors were the knowledge score, gender, age, and whether the medi-cal institution was equipped with pulse oximeters (all P<0.05). Conclusions:Chinese pediatric healthcare providers need to further improve their knowledge about and attitudes towards pulse oximetry.Pulse oximeters are evidently under-used.It is urgent to formulate policies or guidelines, strengthen education and training, improve knowledge and attitudes, equip more institutions with pulse oximeters, and popularize their application in medical institutions.