1.Neuroform EZ and Enterprise 2 stents in patients with symptomatic intracranial atherosclerotic stenosis: a comparative study
Shuhai LONG ; Sun YU ; Chengcheng SHI ; Shuailong SHI ; Ji MA ; Jie YANG ; Ye WANG ; Xinwei HAN ; Tengfei LI
Chinese Journal of Neuromedicine 2023;22(1):27-36
Objective:To explore the stent apposition and safety of Neuroform EZ and Enterprise 2 stents in treatment of symptomatic intracranial atherosclerotic stenosis (sICAS), and their influencing factors for in-stent restenosis.Methods:A total of 143 sICAS patients treated by Enterprise 2 stents (implanted 143 Enterprise 2 stents, E2 group) and 202 patients treated by Neuroform EZ stents (implanted 202 Neuroform EZ stents, EZ group) were selected from Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University from January 2017 to January 2022. Stent apposition was evaluated based on reconstructive images of high-resolution flat detector CT. The complications 30 d after surgery and during 6-24 months of follow-up were recorded. Based on DSA or CTA 6 months after surgery, the patency of the two stents was evaluated. Univariate analysis and multivariate Logistic regression analysis were used to determine the independent risk factors for in-stent restenosis.Results:(1) Forty-nine patients had incomplete stent apposition (ISA) after stent release: 24 patients with ISA in E2 group (16.8%, 24/143; 15 of type I and 9 of type II) and 25 with ISA in the EZ group (12.4%, 25/202, 11 of type I and 14 of type II) were found, without statistical difference ( χ 2=1.334, P=0.248); however, ISA incidence in the EZ group (19.0% and 10.3%) was significantly lower than that in the E2 group (41.4% and 25.6%) when the diameter ratio of anterior and posterior vessels of the stenosis lesions≥1.30 or the angle of stent≥75° ( χ 2=4.228, P=0.040; χ 2=4.531, P=0.033). (2) Within 30 d of stenting, 17 patients developed neurological dysfunction-related complications: 8 patients in EZ group and 9 in E2 group were noted, without significant difference ( P=0.324). Clinical follow-up was obtained in 317 patients, and 20 patients developed long-term stroke associated with responsible lesion vessels: 12 patients in EZ group and 8 in E2 group were noted, without significant difference ( P=0.995). (3) Totally, 298 patients received imaging follow-up 6 months after surgery, and 65 patients developed in-stent restenosis: 36 patients in EZ group and 29 in E2 group were noted, without significant difference ( χ 2=0.309, P=0.578). Multivariate Logistic regression analysis showed that diabetes ( OR=2.714, 95% CI: 1.437-5.126, P=0.002), stent apposition ( OR=3.435, 95% CI: 1.223-9.652, P=0.019), lesion stenosis length ( OR=1.176, 95% CI: 1.065-1.300, P=0.001) and immediate postoperative residual stenosis ( OR=1.038, 95% CI: 1.004-1.074, P=0.029) were independent influencing factors for in-stent restenosis. Conclusions:Enterprise 2 and Neuroform EZ stents have high stent apposition and safety in sICAS treatment, but in cases with large diameter ratio of the anterior and posterior vessels of the stenosis lesions (diameter ratio≥1.30) or large angle of the stent (≥75°), Neuroform EZ stent has better stent apposition. Patients with diabetes, ISA, long lesion stenosis or high residual stenosis may trend to have in-stent restenosis.
2.Vascular suture, closure and occlusion devices at femoral artery puncture hemostasis after neuro-intervention: a clinical comparative study
Shuailong SHI ; Shuhai LONG ; Sun YU ; Chengcheng SHI ; Ji MA ; Renying MIAO ; Yan SONG ; Xinwei HAN ; Tengfei LI
Chinese Journal of Radiology 2024;58(1):71-78
Methods:From February 2018 to January 2022, the clinical data of 1 123 patients who underwent Starclose vascular closure device, Angio-Seal and Exoseal vascular occlusion devices and Perclose ProGlide vascular suture device at femoral artery puncture hemostasis after neuro-intervention, in the Department of Interventional Radiology (Eastern District), The First Affiliated Hospital of Zhengzhou University, were retrospectively analyzed. The patients were divided into three groups based on the intervention method: the closure group (Starclose, n=271), the occlusion group (Angio-Seal, n=327 and Exoseal, n=352) and the suture group (ProGlide, n=173). Next, the hemostatic efficacy and complications associated with the three devices were analyzed and compared. Additionally, regression analysis was conducted to identify any relevant factors that may contribute to complications. Results:Three vascular hemostatic devices demonstrated effective hemostasis and the success rate were 92.6% in the closure group (Starclose), 93.4% in the occlusion group (Angio-Seal 93.0% and Exoseal 93.8%) and 89.6% in the suture group (ProGlide). There was no statistically significant difference( χ2=3.026, P=0.388). Single or multiple complications were observed in 102 patients (9.1%), including local oozing (16 cases in the closure group, 39 cases in the occlusion group, 13 cases in the suture group), local hematoma (14 cases in the closure group, 31 cases in the occlusion group, 11 cases in the suture group), pseudoaneurysm (13 cases in the closure group, 35 cases in the occlusion group, 10 cases in the suture group), local infection (2 cases in the closure group, 3 cases in the occlusion group, 1 case in the suture group). There were no statistically significant differences ( P>0.05). Moreover, serious complications such as femoral artery occlusion, embolus shedding and permanent nerve injury weren′t observed in the three groups. Multivariate logistic regression analysis revealed that overweight ( OR=1.562,95% CI 1.023—2.385, P=0.039), femoral artery with calcified plaque ( OR=1.934,95% CI 1.172-3.189, P=0.010), combined use of multiple antiplatelet drugs ( OR=1.769,95% CI 1.103—2.839, P=0.018), use of an 8F sheath( OR=2.824,95% CI 1.406—5.671, P=0.004) and the operator′s proficiency ( OR=0.508,95% CI 0.328—0.788, P=0.002) were the independent factors influencing complications, of which the first four were identified as risk-promoting factors for complications while the operator′s rich experience and high proficiency were the protective factors. Conclusions:Three hemostatic devices demonstrate effective hemostasis and comparable rates of complications at femoral artery puncture hemostasis after neuro-intervention. Overweight, femoral artery with calcified plaque, combined use of multiple antiplatelet drugs, use of an 8 F sheath and the operator′s proficiency were independent factors influencing complications.Ojective:To investigate the efficacy and complications associated with vascular suture, closure and occlusion devices at femoral artery puncture hemostasis after neuro-intervention.
3.Enterprise 1 stent and Enterprise 2 stent in treating symptomatic intracranial atherosclerosis stenosis: a comparative study
Shuhai LONG ; Shuailong SHI ; Sun YU ; Chengcheng SHI ; Ji MA ; Jie YANG ; Xinwei HAN ; Tengfei LI
Chinese Journal of Neuromedicine 2023;22(3):231-239
Objective:To compare the efficacies of Enterprise 1 stent and Enterprise 2 stent in treating symptomatic intracranial atherosclerotic stenosis (ICAS).Methods:From January 2018 to April 2021, 76 patients with symptomatic ICAS treated by Enterprise 2 stent (implanting Enterprise 2 stents, EP2 group) and 52 patients with symptomatic ICAS treated with Enterprise 1 stent (implanting Enterprise 1 stents, EP1 group) were chosen from Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University. DSA was performed immediately after stent implantation and residual vascular stenosis rate was analyzed and compared between the 2 groups. Stent apposition of the 2 groups were evaluated according to reconstruction images of high-resolution flat detector CT; patients were divided into incomplete stent apposition (ISA) group and complete stent apposition group, accordingly; their clinical data were compared. Multivariate Logistic regression was used to analyze the independent influencing factors for ISA. Incidences of perioperative complications and short-term in-stent restenosis (6 months after implantation) in the EP2 group and EP1 group were observed.Results:Intracranial stent was successfully implanted in all patients, with technical success rate of 100%. Significant difference was noted in EP1 group between pre-implanted vascular stenosis rate (80.85±12.14)% and post-implanted residual vascular stenosis rate ([21.44±8.11]%, P<0.05); significant difference was noted in EP2 group between pre-implanted vascular stenosis rate (81.83±12.85)% and post-implanted residual vascular stenosis rate ([21.53±7.76]%, P<0.05); no significant difference was noted in pre-implanted vascular stenosis rate, post-implanted residual stenosis rate, or angles of stent between EP1 group and EP2 group ( P>0.05). According to high-resolution flat detector CT scan, the ISA incidence in EP2 group (10.5%) was significantly lower than that in EP1 group (25.0%, P<0.05); compared with the complete stent apposition group, the ISA group had significantly higher post-implanted residual stenosis rate, higher proportions of patients with calcification at the stenosis, larger angles of stent, higher diameter ratio of anterior and posterior vessels of the stenosis lesions, and lower proportion of patients with Enterprise 2 stent implantation ( P<0.05). Multivariate Logistic regression analysis showed that the angle of stents, diameter ratio of anterior and posterior vessels of the stenosis lesions and Enterprise 2 stent implantation were independent influencing factors for stent apposition; and Enterprise 2 stent implantation was an proactive factor for complete stent apposition. Perioperative complication rate showed significant difference between EP1 group and EP2 group (1.3% vs. 7.7%, P<0.05). Short-term in-stent restenosis between EP2 group and EP1 group was significantly different (26.1% vs. 7.0%, P<0.05). Conclusion:Compared with Enterprise 1 stent, Enterprise 2 stent has better apposition, higher safety, and lower incidence of short-term in-stent restenosis, enjoying clinical application value in treating symptomatic ICAS.
4.Wallstent stent overlapping implantation in common carotid artery aneurysms: an experimental study
Tengfei LI ; Qi TIAN ; Shuailong SHI ; Shuhai LONG ; Renying MIAO ; Yi TANG ; Shaofeng SHUI ; Lei YAN ; Dong GUO ; Xuhua DUAN ; Zhen LI ; Xinwei HAN ; Ji MA
Chinese Journal of Neuromedicine 2023;22(11):1091-1097
Objective:To establish the common carotid artery aneurysm models of Wallstent double stent overlapping implantation in miniature pigs, and evaluate the safety and effectiveness of this procedure by observing the imaging and pathological changes.Methods:Sidewall aneurysm and fusiform aneurysm models in Bama miniature pigs were established surgically and 2 Wallstent stents were overlapped and implanted in situ. Aneurysm healing immediately after surgery and during 8 weeks of follow-up were evaluated according to 2D-DSA by O'Kelly-Marotta (OKM) grading scale and Kamran scale; degrees of stent adhesion immediately after surgery and status of stent endothelialization and aneurysm healing at 2, 4, and 8 weeks after surgery were observed by high resolution C-arm CT(HR-CBCT) and optical coherence tomography (OCT); and the changes of stent endothelialization were evaluated by comparing the HR-CBCT and OCT results with histopathology at 8 weeks after surgery. Perioperative adverse events were recorded.Results:After successful establishment of common carotid artery aneurysm models (including 4 sidewall aneurysms and 4 fusiform aneurysms with average diameter of [11.0±2.8] mm) in 8 miniature pigs, a total of 16 Wallstent stents (2 in each aneurysm) were implanted across the aneurysmal neck, with a technical success rate of 100%. No serious complications such as acute stent thrombosis, or aneurysm rupture and bleeding were observed in the perioperative period. The 2D-DSA immediately after surgery showed obvious intracranial contrast agent retention in 6 patients (1 patient in grading 1, 3 in grading 2, and 2 in grading 3) and aneurysm occlusion in 2 patients (grading 4). Eight weeks after follow-up, all 8 aneurysms had complete occlusions (grading 4); and 2 experimental pigs had in-stent restenosis, with stenosis rates of 52% and 67%, respectively. HR-CBCT and OCT immediately after surgery and during follow-up indicated that the stent metal braid was gradually covered by proliferating intima, with disappeared aneurysm. The cause of in-stent restenosis in 2 experimental pigs was local intima hyperplasia resulted from poor stent adhesion, and pathological findings indicated that the intima hyperplasia was mainly composed of smooth muscle cells and fibrous connective tissues.Conclusion:In animal models, Wallstent stent overlapping implantation is safe and effective in common carotid aneurysms, but intraoperative adverse adhesion of overlapping stent should be avoided.
5.Imaging features of severe unilateral transverse sinus and sigmoid sinus thromboses and efficacy and safety of intravascular interventional therapy in them
Tengfei LI ; Qi TIAN ; Shuailong SHI ; Jie YANG ; Ye WANG ; Zhen CHEN ; Yuncai RAN ; Baohong WEN ; Dong GUO ; Shaofeng SHUI ; Xinwei HAN ; Xiao LI ; Ji MA
Chinese Journal of Neuromedicine 2024;23(1):42-47
Objective:To summarize the imaging features of severe unilateral transverse sinus and sigmoid sinus thromboses, and evaluate the efficacy and safety of intravascular interventional therapy in them.Methods:Thirty-seven patients with severe unilateral transverse sinus and sigmoid sinus thromboses clinically mainly manifested as intracranial hypertension and accepted endovascular intervention in Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University from June 2012 to September 2022 were chosen; their clinical data were retrospectively analyzed and imaging features were summarized. Short-term efficacy was evaluated according to blood flow restoration degrees and pressure gradient reduction in the occlusive sinus and modified neurological symptoms before and after endovascular intervention. Hospitalized complications were observed; safety and long-term efficacy were evaluated according to postoperative clinical follow-up and imaging results 6-12 months after endovascular intervention.Results:(1) Preoperative brain MRI and (or) CT showed different degrees of swelling of the brain tissues, with the affected side as the target; mixed signals/density shadow could be seen in the blocked transverse sinus and sigmoid sinus; venous cerebral infarction or post-infarction cerebral hemorrhage could be combined in some patients. MRV, CTV and DSA showed poor or completely occluded transverse sinus and sigmoid sinus while normal in the contralateral side; obvious thrombus filling-defect was observed in the occluded venous sinus after mechanical thrombolysis. (2) Occlusive sinus blood flow was restored in all patients after endovascular intervention, and pressure gradient of the occlusive segment decreased from (16.6±3.3) mmHg before to (2.8±0.8) mmHg after endovascular intervention. Before discharge, clinical symptoms of all patients were significantly improved (modified Rankin scale [mRS] scores of 0 in 30 patients, 1 in 5 patients, 2 in 1 patient and 3 in 1 patient), and 2 patients had unilateral limb movement disorder (muscle strength grading III and IV, respectively). All patients received clinical follow-up for (9.6±3.0) months. At the last follow-up, neurological function obviously improved compared with that before endovascular intervention, without new neurosystem-related symptoms (mRS scores of 0 in 30 patients, 1 in 6, and 2 in 1 patient). In 34 patients received MRV or DSA follow-up, 28 had complete recanalization of occlusive sinus and 6 had partial recanalization, without obvious stenosis or recurrent occlusion.Conclusions:Severe unilateral transverse sinus and sigmoid sinus thrombosis can cause local intracranial venous blood stasis, and then cause "increased regional venous sinus pressure", which is manifested as unilateral brain tissue swelling and even venous cerebral infarction or post-infarction cerebral hemorrhage. Early diagnosis and endovascular intervention can obviously improve the prognosis of these patients, enjoying good safety.
6.Effect of MSI2 on proliferation and apoptosis imbalance of KGN cells induced by DHT
Youwen Du ; Haitao Shi ; Shuailong Han ; Shumin Zhang ; Chaoqi Guan ; Tianjuan Wang ; Linxin Pan
Acta Universitatis Medicinalis Anhui 2023;58(3):464-470
Objective:
To study the effect of Musashi-2 ( MSI2 ) overexpression on the imbalance of proliferation and apoptosis of human ovarian granulosa cell line (KGN) induced by dihydrotestosterone (DHT) .
Methods:
The gene expression profiles of human ovarian granulosa cells ( GCs) in primary culture were statistically analyzed to screen the differentially expressed genes.pcDNA3. 1-MSI2 eukaryotic expression plasmid was constructed and transiently transfected into the KGN cells,and the overexpression effect of MSI2 was detected by Quantitative Real-time PCR (RT-qPCR) and Western blot.After overexpressing MSI2 in DHT induced KGN cells,MTT colorimetry and Edu staining were used to detect the proliferation of cells in each group,and flow cytometry ( FCM) was further used to detect the apoptosis of cells in each group.
Results:
The mRNA expression level of MSI2 gradually decreased during the primary culture of human ovarian GCs.And pcDNA3. 1-MSI2 was successfully constructed and transfected into KGN cells to improve the mRNA and protein expression levels of MSI2.Then MTT,EdU and FCM results showed that compared with the blank group,DHT induction could significantly reduce the proliferation rate and increase the apoptosis rate of KGN cells (P <0. 05) .However,after MSI2 overexpression,the proliferation rate of KGN cells increased and the apoptosis rate decreased (P <0. 05) ,which were close to the blank group.
Conclusion
Overexpression of MSI2 can effectively alleviate the imbalance of proliferation and apoptosis of KGN cells induced by DHT,indicating that MSI2 plays an important role in GCs growth and follicle development.