2.Simulation research on gastric emptying measurement experiment by electrical impedance tomography with three-layer electrodes
Lei WANG ; Shu ZHAO ; Juan DENG ; Yan WANG ; Hong SHA
International Journal of Biomedical Engineering 2016;39(2):107-110,后插4
Objective To verify the effectiveness of electrical impedance tomography (EIT) with multi-layer electrodes in gastric emptying measurement by simulation experiments using EIT with three-layer electrodes.Methods Firstly,EIT system with three-layer electrodes and gastric emptying measurement simulation equipment was designed and constructed to simulate gastric emptying process and obtain EIT reconstruction images.Secondly,the region where the electrical characteristic of gastric changes was selected as region of interest.Finally,the relative impedance change rate in region of interest for every image obtained from all three layers was consecutively recorded,then the gastric emptying curve was formed and gastric emptying time was calculated.Results There are obvious differences among the sharp of impedance change curves of interested region for three layers,and the gastric emptying time and process of each layer is also different from one another.It is suggested that the passing path and emptying manner of food in gastric emptying process reflected by EIT images varied from layer to layer.Therefore,the necessity and feasibility of using EIT with three-layer electrodes in gastric emptying measurement study is verified.Conclusions EIT with three-layer electrodes can provide more abundant information of gastric motility function associated with gastric emptying pathology and physiology state.It is likely to be a noninvasive,convenient and effective imaging method for the detection and evaluation research on gastric emptying and gastric motility.
4.Advanced Development of Multi-information Acquisition System on Pulse Tracings of Traditional Chinese Medicine
Hong SHA ; Shu ZHAO ; Yan WANG ; Chaoshi REN ;
China Journal of Traditional Chinese Medicine and Pharmacy 2005;0(01):-
According to the multi-information characteristic of pulse tracings in traditional Chinese medicine(TCM) and the dynamic analysis and identification technique of sonogram,the multi-information detection system of pulse examination was constructed by combining B-type ultrasound and flexible transducer.It made information integration of supersonic dynamic image,pressure pulse wave,photoelectric capacity pulse wave and electrocardiogram,and though the aggregate analysis of computer information processing technique,established the pulse tracings signature analysis method,formed optimized solving scheme for describing the four attributes("location,velocity,shape and potential") of pulse examination in TCM.From the multi-information data of healthy people's pulse tracings collected by this system,it can be infer that the new method of objectification of pulse examination referred in this article is feasible,and have gain the prospective effect.It provides a new method and characteristic data for the clinical study of objectification of pulse examination and teaching of TCM.
5.Critical Antigenic Structure in Inducing Immune Damage of Peripheral Nerve Following Campylobacter Jejuni Infection
xiao-hong, WANG ; xiao-mei, SHU ; bing-zhu, YANG
Journal of Applied Clinical Pediatrics 2004;0(12):-
0.05).3.Thirty-three point three percent of animals from parental strain group were found fibrillations potentials and the po-sitive sharp waves in gastrocnemius electromyogram,no obvious abnormal waves were found in animals from both waaF mutant and control group.Conclusions The ganglioside-like epitope in LOS of CJ is critical antigen in inducing GM1-IgG antibody and in inducing conduction block of peripheral nerve,therefore,provide a support for the molecular mimicry theory as a pathogenesis in the axonal GBS following CJ infection.
6.Clinical Efficacy of Entecavir for Chronic Serious Hepatitis B
Hong WANG ; Shu YANG ; Xiuzhong ZENG ; Qiangsheng XU ; Zhemei HUANG
China Pharmacy 2007;0(26):-
OBJECTIVE: To discuss the significance of Entecavir(ETV) in the treatment of chronic serious hepatitis B(HBV).METHODS: 54 patients with chronic serious hepatitis B were assigned to receive combined therapy in which antiviral drugs such as interferon and(or) nucleoside(acid) analogues antiviral drugs were excluded(control group,n=26) or combined therapy in combination with entecavir(0.5 mg?d-1) qd(treatment group,n=28).The course of treatment in both groups were 6 weeks.The hepatic function,HBV markers and HBV-DNA quantitation were deteted every two weeks.The improvement rate of patients after the completion of treatment were recorded.RESULTS: In the follow-up of six weeks,serum HBV-DNA and total bilirubin levels decreased markedly,and significant difference was noted between compared with the control group;ALT,AST,ALB and PT decreased in both groups,but the differnces between the two groups were not significant;there was no signficnant differnce in improvement rate between the treatment group and the control group(89.3% versus 84.6%).CONCLUSION: Entecavir can rapidly lower serum HBV-DNA level,downregulate bilirubin level,improve liver function,improve patients prognosis in patients with hepatitis B,thus it can be used to treat serious hepatitis B.However,used in short term,the survival rate of patients with severe hepatitis B can hardly be improved.
7.Value of SWI in intravenous thrombolytic therapy of acute cerebral infarction
Youwei ZHANG ; Long SHU ; Yingrui WANG ; Hong LI
Journal of Practical Radiology 2017;33(8):1171-1173,1208
Objective To investigate the decisional value of susceptibility weighted imaging(SWI) in intravenous thrombolytic therapy to acute cerebral infarction.Methods According to cerebral microbleeds(CMBs) by SWI, 35 cases of acute cerebral infarction in window-time random were divided into experimental group(14 cases) with CMBs and control group(21 cases) without CMBs.After intravenous thrombolysis, the number of hemorrhagic transformation(HT) was counted by SWI, and statistic difference was compared between the experimental group and the control group(P<0.05).Results After intravenous thrombolytic therapy of acute infarction,12 cases with HT among experimental group, and only 2 cases with HT among control group, there was significant statistically difference between two groups(P<0.05).Conclusion SWI sequence has greater sensitivity in detecting CMBs,and can also assess the state of blood brain barrier(BBB) and vascular wall indirectly.It plays a very important role in giving a decision in the treatment of intravenous thrombolytic with window-time.
8.Simulation and model experiment research of multichannel impedance gastric motility measurement
Lei WANG ; Yunjie TIAN ; Shu ZHAO ; Hong SHA
International Journal of Biomedical Engineering 2015;38(6):357-360,373,后插10
Objective To study the phase correlation of cutaneous multichannel impedance measurements and the contractions, peristalsis of stomach and the conduction properties in space.Methods A spiral gastric body model was rotated to simulate shrinkage and creep of the stomach.In order to verify the feasibility and validity of the multichannel impedance gastric dynamic measurement, experiments with emulation of multichannel impedance gastric motility measuring principle were conducted through three-dimensional simulation on the electrical characteristics of gastric body model in saline tank simulator.Results The emulation results showed that the change of epigastric current density and potential distribution is consistent with the course of moving from top to bottom when lateral edge of model (namely the intumescent location when the stomach is full) after detecting electrodes in sequence.Meanwhile, the measurement voltage wave forms clearly showed the contraction location of stomach after the model rotating for three cycles in a row, and the phase relationship between adjacent measurement channels was also measured.The sixty seconds data acquired by the experiment device proved that voltage wave form of three measurement channels corresponded to the phase relationship of movement status of the gastric body model.Conclusions Cutaneous multichannel wave forms prove a cyclical movement of stomach, and phase difference among the multichannel signals relating to speed of peristaltic wave, position of the measuring electrodes and channel spacing, etc.This study provides simulation and experimental basis for explanation of quantitative study of conduction properties in space and phase relationship between the results of surface multichannel impedance measurements and the contractions, peristalsis of stomach.
9.Impact of measurement resolution and signal-to-noise ratio of EIT system on reconstruction image
Juan DENG ; Yan WANG ; Shu ZHAO ; Lei WANG ; Hong WANG ; Hong SHA
International Journal of Biomedical Engineering 2015;(3):143-147
Objective Practical electrical impedance tomography (EIT) system with certain measurement resolution (MR) and signal-to-noise ratio (SNR) differs a lot from ideal simulation conditions in EIT methodology research. The aim of this paper was to study the impact of practical system with different MR and SNR on EIT. Methods Based on the ideal simulation boundary voltages of adjacent excitation and adjacent measurement pattern, practical systems whose MR were 0.1 mV and 0.01 mV, SNR ranged from 40-80 dB and no noises were simulated, simulation study for three imaging models A, B and C with different positions in the to-be imaged field under practical system conditions above was carried out using the combined Tikhonov-NOSER regularization algorithm, and error of reconstruction (ER) function and structure similarity (SSIM) function were adopted for quantitative evaluation of image effect. Results There are differences between images obtained under different MR and SNR for different image models. In order to obtain images for three models, SNR of system should be at least 40-50 dB when MR was 0.01 mV. For the goal to obtain high quality images of A, B and C, SNR should be 80, 70 and 60 dB respectively. When MR was 0.1 mV, SNR for obtaining images of A, B, C were 60, 50 and 40 dB. Moreover, the improvement of images with increasing SNR under MR of 0.1 mV was not as obvious as that of MR at 0.01 mV. Conclusions Blind pursuit of single high SNR is of no help to improve system performance and image reconstruction effect except increasing the difficulties in hardware design. The extremity SNR is 50-60 dB for system with MR of 0.01 mV and 60-70 dB for system with MR of 0.1 mV.
10.Screening on high arsenic water source and epidemiological investigation on threatened population of lower reaches of Yellow River in Shangdong Province
Xiu-hong, WANG ; Jian-chao, BIAN ; You-zhang, XIANG ; Shu-fen, GUAN ; Lin, WANG ; Shu-liang, SONG ; Fu-rong, QU
Chinese Journal of Endemiology 2008;27(5):529-531
Objective To screen the arsenic content situation of drinking water in lower reaches of Yellow River and survey the amount of threatened people drinking high arsenic water and the condition of endemic arsenism.Methods Four counties of Yuncheng,Jiaxiang,Dongchangfu and Boxing were selected to colleft the water samples by CroOSS-sectional survey method.The water arsenic content wag determined by semi-quantitative rapid kit.All water samples having arsenic were re-determined by atomic fluorescence spectrometry.And the nurober of threatened people who drinking high arsenic water were investigated.Results In 4765 water wells screened,303 water samples had contained arsenic,arsenic content of 35 samples Was≥0.030 mg/L,12 samples were exceeding the international standard (arsenic content≥0.050 ms/L),they distributed in 3 counties of Dongchangfu,Yuncheng and Jiaxiang.The residents drinking water wells of arsenic content≥0.030 mg/L were surveyed by epidemiological investigation.And in the 28 villages 13 032 residents and 11 Bu8picious patient8 wlere checked out.Conclusion The wells with excesive water arsenic content are existing in the lower reaches of Yellow River and people suspicious of endemic arsenism need to be further identified.