1.Hemodynamic response in cirrhotic patients with transjugular intrahepatic portosystemic shunt
Jingfeng WANG ; Jingqin MA ; Jianjun LUO ; Haiyan CHEN ; Shouling MI ; Shiyao CHEN ; Yangang SU ; Junbo GE
Chinese Journal of Internal Medicine 2020;59(9):700-705
Objective:To discuss the effects of transjugular intrahepatic portosystemic shunt (TIPS) procedure on hemodynamics in cirrhotic patients.Methods:A total of 23 cirrhotic patients for TIPS insertion were enrolled from January 2018 to October 2018. Serum N-terminal pro-B-type natriuretic peptide (NT-proBNP), transthoracic echocardiography and non-invasive cardiac output measurement based on impedance cardiogram were carried out before and 24h, 1 month, 6 months after TIPS in order to observe cardiac function and hemodynamic changes after TIPS.Results:Significant increases in right atrial area [(17.2±4.0) cm 2 vs. (15.0±3.4) cm 2, P<0.05], right ventricular area [(15.1±3.8) cm 2 vs. (13.7±3.5) cm 2, P<0.05] and left ventricular volume [(97.4±21.5) ml vs. (91.1±22.7) ml, P<0.05] were observed 24 h after TIPS. These changes were accompanied with significant reduction in collapsible index of inferior vena cava [(20.7± 8.1)% vs. (28.6±11.3)%, P<0.01] and elevation in pulmonary arterial systolic pressure [(36.0±8.4) mmHg (1 mmHg=0.133 kPa) vs. (31.8±5.4) mmHg, P<0.01]. There also existed significantly elevated serum NT-proBNP [(551.2±325.1) ng/L vs. (124.2±94.4) ng/L, P<0.01], cardiac output [(5.82±0.96) L/min vs. (5.12±1.28) L/min, P<0.01], cardiac index [(3.47±0.64) L·min -1·m -2 vs. (3.05±0.78) L·min -1·m -2, P<0.01], early diastolic filling rate [(59.0±14.3)% vs. (54.5±11.0)%, P<0.05], and reduced systemic vascular resistance index (SVRi) [(1 798.4±357.3) dyne·s·cm -5·m -2 vs. (2 195.7±508.7) dyne·s·cm -5·m -2, P<0.01] 24 h after TIPS. At the end of 6-month follow-up, all these parameters, but not SVRi, returned towards baseline values. Moreover, peak early to late diastolic tissue velocity ratio at the level of lateral mitral annulus (E′/A′) was significantly higher at the end of 6-month follow-up than that at baseline (1.06±0.32 vs. 0.90±0.45, P<0.05). Neither the right ventricular fractional area changes nor the left ventricular ejection fractions during the follow-up period were different from those at baseline ( P>0.05). Conclusion:Cirrhotic patients who had no cardiovascular pathologies had adequate adaptation and good compensation ability to reach a new hemodynamic homeostasis for the increased volume load after TIPS insertion.