1.Popliteal Artery Adventitia Cyst
Shohei Yoshida ; Shinichi Hiromatsu ; Kentaro Sawada ; Takahiro Shojima ; Ryo Kanamoto ; Shinichi Imai ; Hiroyuki Otsuka ; Hiroyuki Tanaka
Japanese Journal of Cardiovascular Surgery 2017;46(4):182-185
A 60 year old man presented with a history of right leg claudication which occurred after walking a distance of 200 m. He had no history of cardiovascular risk factors or trauma in the lower extremities. Palpation disclosed no right popliteal or pedal pulse. Ankle-brachial pressure index (ABI) was 0.60 on the affected side. Computed tomography (CT) demonstrated the presence of a highly stenotic lesion in the right popliteal artery due to compression from periarterial polycystic masses. Magnetic resonance imaging (MRI) revealed no communication to the knee joint bursa. Further, angiography showed a beak-like severe stenosis on the knee of the right popliteal artery. Based on the results of these three imaging techniques we confirmed the diagnosis of cystic adventitial disease (CAD). The patient underwent a surgical exploration of his popliteal artery through a posterior approach. Evacuation of all cysts by longitudinal incision of his adventitia yielded yellow mucoid gelatinous material. The popliteal artery was replaced using the great saphenous vein because the previous imaging showed thrombus formation at the cyst site. He had an uneventful postoperative recovery with ABI of 1.10.
2.Infected Abdominal Aortic Aneurysm with a Previous History of Coronary Artery Bypass Grafting with the Right Gastroepiploic Artery
Shinichi Imai ; Kentaro Sawada ; Eiji Nakamura ; Shohei Yoshida ; Hayato Fukuda ; Satoru Tobinaga ; Seiji Onitsuka ; Shinichi Hiromatsu ; Hidetoshi Akashi ; Hiroyuki Tanaka
Japanese Journal of Cardiovascular Surgery 2016;45(2):84-88
We report a case of successful anatomical reconstruction with omentopexy of an infected abdominal aortic aneurysm (AAA) in a patient with a previous history of coronary artery bypass grafting with the right gastroepiploic artery. A 60-year-old man was referred to our institute because of fever and abdominal pain during hemodialysis for chronic renal failure. Antibiotic therapy was started after computed tomography revealed an infected abdominal aortic aneurysm. After infection control, surgical treatment was scheduled. At surgery, left axillo-bifemoral bypass was performed first, because it was unclear whether the omentum was large enough for omentopexy. At laparotomy, adequate omentum and infective AAA were confirmed. AAA repair using a rifampicin-soaked graft, and omentopexy were performed. Enterobacter aerogenes was detected from the resected aortic wall. After the operation, intravenous antibiotic was used for 25 days until CRP was normalized. One year follow-up showed no sign of re-infection.
3.Effects of Incentive Spirometry on Respiratory Motion in Healthy Subjects Using Cine Breathing Magnetic Resonance Imaging.
Toshiaki KOTANI ; Tsutomu AKAZAWA ; Tsuyoshi SAKUMA ; Shigeyuki NAGAYA ; Masaru SONODA ; Yuji TANAKA ; Takehide KATOGI ; Tetsuharu NEMOTO ; Shohei MINAMI
Annals of Rehabilitation Medicine 2015;39(3):360-365
OBJECTIVE: To investigate the effectiveness of incentive spirometry on respiratory motion in healthy subjects using cine breathing magnetic resonance imaging (MRI). METHODS: Ten non-smoking healthy subjects without any history of respiratory disease were studied. Subjects were asked to perform pulmonary training using incentive spirometry every day for two weeks. To assess the effectiveness of this training, pulmonary function tests and cine breathing MRI were performed before starting pulmonary training and two weeks after its completion. RESULTS: After training, there were significant improvements in vital capacity (VC) from 3.58+/-0.8 L to 3.74+/-0.8 L and in %VC from 107.4+/-10.8 to 112.1+/-8.2. Significant changes were observed in the right diaphragm motion, right chest wall motion, and left chest wall motion, which were increased from 55.7+/-9.6 mm to 63.4+/-10.2 mm, from 15.6+/-6.1 mm to 23.4+/-10.4 mm, and from 16.3+/-7.6 mm to 22.0+/-9.8 mm, respectively. CONCLUSION: Two weeks of training using incentive spirometry provided improvements in pulmonary function and respiratory motion, which suggested that incentive spirometry may be a useful preoperative modality for improving pulmonary function during the perioperative period.
Diaphragm
;
Magnetic Resonance Imaging*
;
Motivation*
;
Perioperative Period
;
Respiration*
;
Respiratory Function Tests
;
Spirometry*
;
Thoracic Wall
;
Vital Capacity
4.Onigiri Esophagography as a Screening Test for Esophageal Motility Disorders
Shohei HAMADA ; Eikichi IHARA ; Kazumasa MUTA ; Masafumi WADA ; Yoshitaka HATA ; Hiroko IKEDA ; Yoshimasa TANAKA ; Haruei OGINO ; Takatoshi CHINEN ; Yoshihiro OGAWA
Journal of Neurogastroenterology and Motility 2022;28(1):43-52
Background/Aims:
No screening test for esophageal motility disorder (EMD) has been established, the objective of this study is to examine the potential usefulness of our newly developed “Onigiri esophagography” combined with an obstruction level (OL) classification system in screening for EMD.
Methods:
A total of 102 patients with suspected EMDs who underwent both high-resolution manometry (HRM) and Onigiri esophagography between April 2017 and January 2019 were examined. The EMD diagnosis was performed based on the Chicago classification version 3.0 by HRM. Onigiri esophagography was performed using a liquid medium (barium sulfate) followed by a solid medium, which consisted of an Onigiri (a Japanese rice ball) with barium powder. The extent of medium obstruction was assessed by the OL classification, which was defined in a stepwise fashion from OL0 (no obstruction) to OL4 (severe obstruction).
Results:
The patients with OL0 (32.3%), OL1 (50.0%), OL2 (88.0%), OL3 (100.0%), and OL4 (100.0%) were diagnosed EMDs by HRM. The area under the curve, as determined by a receiver operating characteristic analysis, for the OL classification was 0.86. Using the cutoff value of OL1, the sensitivity and specificity were 87.3% and 61.3%, respectively, while using a cutoff value of OL2, the sensitivity and specificity were 73.2% and 90.3%, respectively.
Conclusion
In conclusion, Onigiri esophagography combined with the OL classification system can be used as a screening test for EMDs with a cutoff value of OL1.
5.Planning evaluation of stereotactic magnetic resonance–guided online adaptive radiosurgery for kidney tumors close to the organ at risk: is it valuable to wait for good timing to perform stereotactic radiosurgery?
Takaya YAMAMOTO ; Shohei TANAKA ; Noriyoshi TAKAHASHI ; Rei UMEZAWA ; Yu SUZUKI ; Keita KISHIDA ; So OMATA ; Kazuya TAKEDA ; Hinako HARADA ; Kiyokazu SATO ; Yoshiyuki KATSUTA ; Noriyuki KADOYA ; Keiichi JINGU
Radiation Oncology Journal 2025;43(1):40-48
Purpose:
This study aimed to investigate changes in target coverage using magnetic resonance–guided online adaptive radiotherapy (MRgoART) for kidney tumors and to evaluate the suitable timing of treatment.
Materials and Methods:
Among patients treated with 3-fraction MRgoART for kidney cancer, 18 tumors located within 1 cm of the gastrointestinal tract were selected. Stereotactic radiosurgery planning with a prescription dose of 26 Gy was performed using pretreatment simulation and three MRgoART timings with an adapt-to-shape method. The best MRgoART plan was defined as the plan achieving the highest percentage of planning target volume (PTV) coverage of 26 Gy. In clinical scenario simulation, MRgoART plans were evaluated in the order of actual treatment. Waiting for the next timing was done when the PTV coverage of 26 Gy did not achieve 95%–99% or did not increase by 5% or more compared to the pretreatment plan.
Results:
The median percentages of PTV receiving 26 Gy in pretreatment and the first, second, and third MRgoART were 82% (range, 19%), 63% (range, 7% to 99%), 88% (range, 31% to 99%), and 95% (range, 3% to 99%), respectively. Comparing pretreatment simulation plans with the best MRgoART plans showed a significant difference (p = 0.025). In the clinical scenario simulation, 16 of the 18 planning series, including nine plans with 95%–99% PTV coverage of 26 Gy and seven plans with increased PTV coverage by 5% or more, would be irradiated at a good timing.
Conclusion
MRgoART revealed dose coverage differences at each MRgoART timing. Waiting for optimal irradiation timing could be an option in case of suboptimal timing.
6.Planning evaluation of stereotactic magnetic resonance–guided online adaptive radiosurgery for kidney tumors close to the organ at risk: is it valuable to wait for good timing to perform stereotactic radiosurgery?
Takaya YAMAMOTO ; Shohei TANAKA ; Noriyoshi TAKAHASHI ; Rei UMEZAWA ; Yu SUZUKI ; Keita KISHIDA ; So OMATA ; Kazuya TAKEDA ; Hinako HARADA ; Kiyokazu SATO ; Yoshiyuki KATSUTA ; Noriyuki KADOYA ; Keiichi JINGU
Radiation Oncology Journal 2025;43(1):40-48
Purpose:
This study aimed to investigate changes in target coverage using magnetic resonance–guided online adaptive radiotherapy (MRgoART) for kidney tumors and to evaluate the suitable timing of treatment.
Materials and Methods:
Among patients treated with 3-fraction MRgoART for kidney cancer, 18 tumors located within 1 cm of the gastrointestinal tract were selected. Stereotactic radiosurgery planning with a prescription dose of 26 Gy was performed using pretreatment simulation and three MRgoART timings with an adapt-to-shape method. The best MRgoART plan was defined as the plan achieving the highest percentage of planning target volume (PTV) coverage of 26 Gy. In clinical scenario simulation, MRgoART plans were evaluated in the order of actual treatment. Waiting for the next timing was done when the PTV coverage of 26 Gy did not achieve 95%–99% or did not increase by 5% or more compared to the pretreatment plan.
Results:
The median percentages of PTV receiving 26 Gy in pretreatment and the first, second, and third MRgoART were 82% (range, 19%), 63% (range, 7% to 99%), 88% (range, 31% to 99%), and 95% (range, 3% to 99%), respectively. Comparing pretreatment simulation plans with the best MRgoART plans showed a significant difference (p = 0.025). In the clinical scenario simulation, 16 of the 18 planning series, including nine plans with 95%–99% PTV coverage of 26 Gy and seven plans with increased PTV coverage by 5% or more, would be irradiated at a good timing.
Conclusion
MRgoART revealed dose coverage differences at each MRgoART timing. Waiting for optimal irradiation timing could be an option in case of suboptimal timing.
7.Planning evaluation of stereotactic magnetic resonance–guided online adaptive radiosurgery for kidney tumors close to the organ at risk: is it valuable to wait for good timing to perform stereotactic radiosurgery?
Takaya YAMAMOTO ; Shohei TANAKA ; Noriyoshi TAKAHASHI ; Rei UMEZAWA ; Yu SUZUKI ; Keita KISHIDA ; So OMATA ; Kazuya TAKEDA ; Hinako HARADA ; Kiyokazu SATO ; Yoshiyuki KATSUTA ; Noriyuki KADOYA ; Keiichi JINGU
Radiation Oncology Journal 2025;43(1):40-48
Purpose:
This study aimed to investigate changes in target coverage using magnetic resonance–guided online adaptive radiotherapy (MRgoART) for kidney tumors and to evaluate the suitable timing of treatment.
Materials and Methods:
Among patients treated with 3-fraction MRgoART for kidney cancer, 18 tumors located within 1 cm of the gastrointestinal tract were selected. Stereotactic radiosurgery planning with a prescription dose of 26 Gy was performed using pretreatment simulation and three MRgoART timings with an adapt-to-shape method. The best MRgoART plan was defined as the plan achieving the highest percentage of planning target volume (PTV) coverage of 26 Gy. In clinical scenario simulation, MRgoART plans were evaluated in the order of actual treatment. Waiting for the next timing was done when the PTV coverage of 26 Gy did not achieve 95%–99% or did not increase by 5% or more compared to the pretreatment plan.
Results:
The median percentages of PTV receiving 26 Gy in pretreatment and the first, second, and third MRgoART were 82% (range, 19%), 63% (range, 7% to 99%), 88% (range, 31% to 99%), and 95% (range, 3% to 99%), respectively. Comparing pretreatment simulation plans with the best MRgoART plans showed a significant difference (p = 0.025). In the clinical scenario simulation, 16 of the 18 planning series, including nine plans with 95%–99% PTV coverage of 26 Gy and seven plans with increased PTV coverage by 5% or more, would be irradiated at a good timing.
Conclusion
MRgoART revealed dose coverage differences at each MRgoART timing. Waiting for optimal irradiation timing could be an option in case of suboptimal timing.
8.Planning evaluation of stereotactic magnetic resonance–guided online adaptive radiosurgery for kidney tumors close to the organ at risk: is it valuable to wait for good timing to perform stereotactic radiosurgery?
Takaya YAMAMOTO ; Shohei TANAKA ; Noriyoshi TAKAHASHI ; Rei UMEZAWA ; Yu SUZUKI ; Keita KISHIDA ; So OMATA ; Kazuya TAKEDA ; Hinako HARADA ; Kiyokazu SATO ; Yoshiyuki KATSUTA ; Noriyuki KADOYA ; Keiichi JINGU
Radiation Oncology Journal 2025;43(1):40-48
Purpose:
This study aimed to investigate changes in target coverage using magnetic resonance–guided online adaptive radiotherapy (MRgoART) for kidney tumors and to evaluate the suitable timing of treatment.
Materials and Methods:
Among patients treated with 3-fraction MRgoART for kidney cancer, 18 tumors located within 1 cm of the gastrointestinal tract were selected. Stereotactic radiosurgery planning with a prescription dose of 26 Gy was performed using pretreatment simulation and three MRgoART timings with an adapt-to-shape method. The best MRgoART plan was defined as the plan achieving the highest percentage of planning target volume (PTV) coverage of 26 Gy. In clinical scenario simulation, MRgoART plans were evaluated in the order of actual treatment. Waiting for the next timing was done when the PTV coverage of 26 Gy did not achieve 95%–99% or did not increase by 5% or more compared to the pretreatment plan.
Results:
The median percentages of PTV receiving 26 Gy in pretreatment and the first, second, and third MRgoART were 82% (range, 19%), 63% (range, 7% to 99%), 88% (range, 31% to 99%), and 95% (range, 3% to 99%), respectively. Comparing pretreatment simulation plans with the best MRgoART plans showed a significant difference (p = 0.025). In the clinical scenario simulation, 16 of the 18 planning series, including nine plans with 95%–99% PTV coverage of 26 Gy and seven plans with increased PTV coverage by 5% or more, would be irradiated at a good timing.
Conclusion
MRgoART revealed dose coverage differences at each MRgoART timing. Waiting for optimal irradiation timing could be an option in case of suboptimal timing.
9.Planning evaluation of stereotactic magnetic resonance–guided online adaptive radiosurgery for kidney tumors close to the organ at risk: is it valuable to wait for good timing to perform stereotactic radiosurgery?
Takaya YAMAMOTO ; Shohei TANAKA ; Noriyoshi TAKAHASHI ; Rei UMEZAWA ; Yu SUZUKI ; Keita KISHIDA ; So OMATA ; Kazuya TAKEDA ; Hinako HARADA ; Kiyokazu SATO ; Yoshiyuki KATSUTA ; Noriyuki KADOYA ; Keiichi JINGU
Radiation Oncology Journal 2025;43(1):40-48
Purpose:
This study aimed to investigate changes in target coverage using magnetic resonance–guided online adaptive radiotherapy (MRgoART) for kidney tumors and to evaluate the suitable timing of treatment.
Materials and Methods:
Among patients treated with 3-fraction MRgoART for kidney cancer, 18 tumors located within 1 cm of the gastrointestinal tract were selected. Stereotactic radiosurgery planning with a prescription dose of 26 Gy was performed using pretreatment simulation and three MRgoART timings with an adapt-to-shape method. The best MRgoART plan was defined as the plan achieving the highest percentage of planning target volume (PTV) coverage of 26 Gy. In clinical scenario simulation, MRgoART plans were evaluated in the order of actual treatment. Waiting for the next timing was done when the PTV coverage of 26 Gy did not achieve 95%–99% or did not increase by 5% or more compared to the pretreatment plan.
Results:
The median percentages of PTV receiving 26 Gy in pretreatment and the first, second, and third MRgoART were 82% (range, 19%), 63% (range, 7% to 99%), 88% (range, 31% to 99%), and 95% (range, 3% to 99%), respectively. Comparing pretreatment simulation plans with the best MRgoART plans showed a significant difference (p = 0.025). In the clinical scenario simulation, 16 of the 18 planning series, including nine plans with 95%–99% PTV coverage of 26 Gy and seven plans with increased PTV coverage by 5% or more, would be irradiated at a good timing.
Conclusion
MRgoART revealed dose coverage differences at each MRgoART timing. Waiting for optimal irradiation timing could be an option in case of suboptimal timing.
10.A Report on an Annual Kampo Medicine Conference Held by Medical Students in the Hokkaido and Tohoku Areas
Shohei OKADA ; Fumiya OMATA ; Takafumi TOGASHI ; Takahisa OKUDA ; Tesshin MIYAMOTO ; Miho OOSUGA ; Kohei TANAKA ; Mami ISHIYAMA ; Aiseio AISO ; Hiromichi YASUI ; Minoru YAEGASHI ; Kahori KUBO ; Soichiro KANEKO ; Tetsuharu KAMIYA ; Natsumi SAITO ; Ryutaro ARITA ; Hidekazu WATANABE ; Hitoshi NISHIKAWA ; Yuka IKENO ; Junichi TANAKA ; Minoru OHSAWA ; Akiko KIKUCHI ; Takehiro NUMATA ; Hitoshi KURODA ; Michiaki ABE ; Shin TAKAYAMA ; Tadashi ISHII
Kampo Medicine 2017;68(1):72-78
Since students who would like to study Kampo medicine more have no opportunity to communicate each other in Northern Japanese Universities, we newly started joint study conferences held by medical students in 2013. The objectives of this paper are to report on these annually held student-based Kampo study conferences in the Hokkaido and Tohoku areas, and the ways each university studies Kampo medicine. In the conference, the students reported on their club activities. Then they studied the history of Kampo medicine and simulation of abdominal diagnosis, and performed group work on case reports together. The number of student participants in these conferences has tripled over 3 years from 18 to 58 (for a total of 111 participants). All members were satisfied with the content. And this reflects medical students' need for a wider perception of Kampo medicine, rather than a limited one gained in their university club activities. We hope this conference will play a major role in other nationwide student-based Kampo study conferences in the years to come.