1.The effectiveness of optical coherence tomography for evaluating peri-implant tissue: A pilot study.
Minoru SANDA ; Makoto SHIOTA ; Chiharu IMAKITA ; Aoi SAKUYAMA ; Shohei KASUGAI ; Yasunori SUMI
Imaging Science in Dentistry 2016;46(3):173-178
PURPOSE: Optical coherence tomography (OCT) has been investigated as a novel diagnostic imaging tool. The utilisation of this equipment has been evaluated through several studies in the field of dentistry. The aim of this preliminary study was to determine through basic experiments the effectiveness of OCT in implant dentistry. MATERIALS AND METHODS: To assess detection ability, we captured OCT images of implants in each of the following situations: (1) implants covered with mucosae of various thicknesses that were harvested from the mandibles of pigs; (2) implants installed in the mandibles of pigs; and (3) implants with abutments and crowns fixed with temporary cement. The OCT images were captured before cementation, after cementation, and after removing the excess submucosal cement. RESULTS: If the thickness of the mucosa covering the implant body was less than 1 mm, the images of the implants were clearly detected by OCT. In the implants were installed in pigs' mandibles, it was difficult to capture clear images of the implant and alveolar bone in most of the samples. Remnants of excess cement around the implants were visible in most samples that had a mucosa thickness of less than 3 mm. CONCLUSION: Currently, OCT imaging of implants is limited. Cement remnants at the submucosal area can be detected in some cases, which can be helpful in preventing peri-implant diseases. Still, though there are some restrictions to its application, OCT could have potential as an effective diagnostic instrument in the field of implant dentistry as well.
Cementation
;
Crowns
;
Dental Implants
;
Dentistry
;
Diagnostic Imaging
;
Mandible
;
Mucous Membrane
;
Peri-Implantitis
;
Pilot Projects*
;
Swine
;
Tomography, Optical Coherence*
2.Application of low-crystalline carbonate apatite granules in 2-stage sinus floor augmentation: a prospective clinical trial and histomorphometric evaluation
Takayuki NAKAGAWA ; Keiko KUDOH ; Naoyuki FUKUDA ; Shohei KASUGAI ; Noriko TACHIKAWA ; Kiyoshi KOYANO ; Yasuyuki MATSUSHITA ; Masanori SASAKI ; Kunio ISHIKAWA ; Youji MIYAMOTO
Journal of Periodontal & Implant Science 2019;49(6):382-396
PURPOSE: The purpose of this study was to elucidate the efficacy and safety of carbonate apatite (CO₃Ap) granules in 2-stage sinus floor augmentation through the radiographic and histomorphometric assessment of bone biopsy specimens.METHODS: Two-stage sinus floor augmentation was performed on 13 patients with a total of 17 implants. Radiographic assessment using panoramic radiographs was performed immediately after augmentation and was also performed 2 additional times, at 7±2 months and 18±2 months post-augmentation, respectively. Bone biopsy specimens taken from planned implant placement sites underwent micro-computed tomography, after which histological sections were prepared.RESULTS: Postoperative healing of the sinus floor augmentation was uneventful in all cases. The mean preoperative residual bone height was 3.5±1.3 mm, and this was increased to 13.3±1.7 mm by augmentation with the CO₃Ap granules. The mean height of the augmented site had decreased to 10.7±1.9 mm by 7±2 months after augmentation; however, implants with lengths in the range of 6.5 to 11.5 mm could still be placed. The mean height of the augmented site had decreased to 9.6±1.4 mm by 18±2 months post-augmentation. No implant failure or complications were observed. Few inflammatory cells or foreign body giant cells were observed in the bone biopsy specimens. Although there were individual differences in the amount of new bone detected, new bone was observed to be in direct contact with the CO₃Ap granules in all cases, without an intermediate layer of fibrous tissue. The amounts of bone and residual CO₃Ap were 33.8%±15.1% and 15.3%±11.9%, respectively.CONCLUSIONS: In this first demonstration, low-crystalline CO₃Ap granules showed excellent biocompatibility, and bone biopsy showed them to be replaced with bone in humans. CO₃Ap granules are a useful and safe bone substitute for two-stage sinus floor augmentation.
Apatites
;
Biopsy
;
Bone Substitutes
;
Carbon
;
Dental Implants
;
Giant Cells, Foreign-Body
;
Humans
;
Individuality
;
Prospective Studies
;
Sinus Floor Augmentation