1.Software design of ultrasound power detecting system
Liming TANG ; Shitao QL ; Tiebing LIU
Chinese Medical Equipment Journal 1989;0(04):-
This paper mainly describes the software design for a new type of ultrasound power detecting system based on instrument, in which data acquisition module, digital filtering module, data conversion module, zero setting and adjustment module. In the required accuracy, this system is more convenient and practical than the former power detecting system.
2.Studies on the prolongation of cardiac allograft survival by alloreactive lymphocytes depletion. indaection of allograft immunotolerance by alloreactive lymphocyte vaccine in recipient preparation
Zhongmin LIU ; Shitao CHUI ; Ming YANG
Journal of Clinical Surgery 2001;0(04):-
Objective Alloreactive lymphocytes specific for graft antigens are implicated in rejection of allograft.This study aims to induce alloreactive lymphocytes depletion or inactivation and allograft immuno tolerance by alloreactive lymphocyte vaccine(ALV).Methods Recipient lymphocytes were expanded for 9-14 days stimulated by donor lymphocytes that had been dealt with mitomycin C.The expanded recipient lymphocytes are termed alloreactive lymphocyte vaccine(ALV).About 0.5?10 7~1.0?10 7cells mixed with freunds complete ajuvant(FCA)were used as ALV to vaccinate itself for 3~4 times as usual. The stimulate index(SI) was measured after vaccination and compared with itself unvaccination. Results The ALV could suppress mixed lymphocyte reaction. The stimulate Index was significantly lower than themselves uninjected with ALV(P
3.Analysis of untypical cystic lymphangioma CT and MRI
Zhongjie HUANG ; Shitao GUO ; Yuan LIU
Chinese Journal of Primary Medicine and Pharmacy 2008;15(2):269-270
Objective To study CT and MRI manifestation of untypical cystic lymphangioma.Methods CT and MRI findings of 8 cases of cystic lymphangioma proved surgically and pathologically were analyzed retrospectively.7 cases were performed by CT and the other by MRI.Results 3 lesions are located at facies cranii,2 lesions at neck,2 lesions are located at mesostenium and 1 lesion is located at chest wall.CT and MRI findings include:(1)dense mass(5 cases);(2)lesion contain solid and water dense(2 cases);(3)lesion contain high dense hematoma(2 cases);(4)calcification in lesion(2 cases);(5)infiltrate the adjacent tissue(3 cases).Conclusion Most majority cystic lymphangioma can be identified by CT and MRI which also helpful to evaluation lymphangioma before surgical treatment.
4.Experimental study of ultrasound sensor based on fiber grating
Shitao QL ; Liming TANG ; Tiebing LIU ; Xingxi ZHU
Chinese Medical Equipment Journal 2003;0(12):-
Optic fiber-grating sensor has many unique advantages and is one of the widely-applied sensors in recent years. The response of FBG sensor to ultrasound was investigated. Results showed that the sensor output intensity was basically linear to the acoustic power. So the optic fiber-grating sensor can be applied to noninvasive detection of internal ultrasound.
5.Application of Kalman filter to measurement of sound power for medical ultrasonic diagnostic equipment
Tiebing LIU ; Liming TANG ; Shitao QL ; Min WU ; Shujing SHEN
Chinese Medical Equipment Journal 1989;0(03):-
A data processing method for the sound power of the medical ultrasonic diagnostic equipment is introduced in this paper. The sound power for the transducer of a medical ultrasonic diagnostic equipment is measured for many times, and then the mathematical model based on the measurement data above is processed with Kalman filter.The output fluctuations for sound power of the equipment and its transducer as well as the measurement errors of sound power meter are eliminated to achieve the true value of sound power. Compared with other mean methods, the method above can improve the dicreteness of the measurements, and thus is worth being applied to processing other measured data.
6.Design of centralized infusion managing and controlling system
Shitao QI ; Liming TANG ; Tiebing LIU ; Min WU
Chinese Medical Equipment Journal 2003;0(10):-
This paper describes the structure, operating principles, design method of both software and hardware of a centralized controlling system of infusion pumps based on CAN bus. The system can monitor the status information and control the infusion parameters of many infusion pumps simultaneously. It provides a more complicated cliaical infusion treatment means, greatly eases the work burden on doctors and nurses, and promotes the effects of treatment and nursing.
7.Establishment of medical instrument quality & safety management system
Liming TANG ; Tiebing LIU ; Min WU ; Shitao QI
Chinese Medical Equipment Journal 2003;0(11):-
The development of medical technology and method more and more relies on medical engineering technology.This paper demonstrates the importance of quality management in medical engineering from many aspects,especially from the establishment of medical instrument quality and safety management system.
8.Research and development of anti-interference portable transfusion-drop counter
Xingxi ZHU ; Xinyong HU ; Shitao QI ; Yun LIU ; Lin LI
Chinese Medical Equipment Journal 2003;0(11):-
Objective To resolve the difficulty in controlling the transfusion speed by medical personnel.Methods By using liquid drop sampling module,pulsing signals of liquid drop were obtained,and then they were enlarged,shaped and the wrong signals from the top and bottom surface of every drop were excluded before the standard triggered signals were sent out to SCM processing circuit,from which the real-time liquid drop speed and the average drop speed in every minute were obtained.Results Anti-interference and portable transfusion-drop counter could show the real-time liquid drop value and the average liquid drop value in every minute.Conclusion Anti-interference and portable transfusion-drop counter is convenient with simple structure and has been used in clinic.
9.Study on requirement forecasting of medical consumptive materials based on Kalman filter
Tiebing LIU ; Liming TANG ; Jingjie YU ; Min WU ; Shitao QI
Chinese Medical Equipment Journal 2003;0(12):-
An analysis method for requirement of medical consumptive materials on Kalman filter is put forward.An analysis mathematical model is established at first,its solution process is carried out at same time,and then an example using this solution is given according to the working practice.At last,the shortcomings using classical Kalman filter were discussed and a new method using adaptive Kalman filter was proposed.
10.Study on measuring method for amplitude of transducer’s tip in ultrasonic surgical apparatus
Tiebing LIU ; Liming TANG ; Min WU ; Shitao QI
Chinese Medical Equipment Journal 1989;0(01):-
Objective To study the measuring method for amplitude of transducer's tip in ultrasonic surgical apparatus, and design a set of practical detecting system with special data processing technique. Methods The system was consisted of stereomicroscope, CCD camera, etc. The images of amplitude measuring were captured and processed and the result was carried out at last. Results The measurement range for amplitude of transducer’s tip was above 190 ?m, the precision was below 10?m, and the repeatability was also ideal. Conclusion The amplitude measuring method has some excellent characters such as directness, simplicity, easy implementation, error estimableness and controllability, etc. It is proved in practice that the effect is nice and the blank in this field in China is filled.