1.Analysis of DNA polymorphism of HLA—DQ locus with PCR/SS0 in Hunan Hans
Chinese Journal of Immunology 1985;0(01):-
Abstract In this paper,the sequences of second exon of DQA1 and DQB1 were amplified byPCR primers,and hybridized with 17 or 23 sequence specific oligonucleotide probes labeled byisotope respectively.The distribution of 10 DQA1 alleles and 17 DQB1 alleles was observed inHunan Hans population.The results showed that the most of DQAI and DQB1 alleles were ex-pressed in Hans,however,their frequencies are different from Caucasoids.
2.Content Determination of AV45,a Labeled Precursor of PET Agent for AβPlaques,and Its Related Substanc-es by HPLC
Shishi MAO ; Jiankang ZHANG ; Rongjun ZHANG ; Xingqin ZHOU
China Pharmacy 2016;27(18):2535-2537
OBJECTIVE:To establish a method for the content determination of AV45(the labeled precursor of PET agent for Aβ plaques)and its related substances. METHODS:HPLC method was performed on the column of Inertsil C18 with mobile phase of 50 mmol/L Disodium hydrogen phosphate solution- acetonitrile(containing 0.01% triethylamine)(15∶85,V/V)at a flow rate of 1.0 ml/min,the detection wavelength was 325 nm,and column temperature was 30 ℃,and volume injection was 20 μl. RESULTS:The AV45 and reaction intermediate as well as individual impurity peaks were well separated;the linear range was 200-1 000 μg/ml for AV45(r=0.999 2)and 20-100 μg/ml for intermediate(r=0.999 6);the detection limit and quantification limit of reaction in-termediate AV45 were 0.1 ng and 0.5 ng,respectively;RSDs of precision,stability and reproducibility tests were lower than 0.5%;recovery of AV45 was 98.93%-101.58%(RSD=0.69%,n=9). CONCLUSIONS:The method is simple and accurate with high specificity and good reproducibility,and suitable for content determination of AV45(the labeled precursor of PET agent for Aβplaques)and its related substances.
3.Total Error and Measurement Uncertainty in Clinical Laboratory Medicine
Shishi ZHANG ; Wei WANG ; Haijian ZHAO ; Zhiguo WANG
Journal of Modern Laboratory Medicine 2016;31(5):153-156
In the clinical laboratory medicine,the measurement uncertainty (MU)is a relatively new concept.Over the years, experts of clinical laboratory medicine from all over the world made a great number of further researches and promote the development of MU,which led clinical laboratories to pay more and more attention to the meanings and functions of MU at the same time.However,because of the habitual using of the total error (TE)in clinical laboratories and similarities between concepts of MU and TE which easily resulted in confusion,a lot of laboratories still cannot completely accept MU.By explai-ning concepts of TE and MU and analyzing the pros and cons of models of TE and MU as well as their functions,the obj ec-tive of this paper is to help clinical laboratories make further comprehensions of TE and MU and understand how to properly use them in practice.
4.Investigation and analysis of current situation about reference intervals of lymphocyte subsets by flow cytometry tests in China
Shishi ZHANG ; Wei WANG ; Falin HE ; Kun ZHONG ; Zhiguo WANG
Chinese Journal of Laboratory Medicine 2016;39(5):356-360
Objective Discussthe reference intervals and their sources of lymphocyte subsets by flow cytometry tests by all Chinese clinical laboratories at 2014 with a comparison of difference between different test systems.Methods Questionnaires about reference intervals were distributed to 212 clinical laboratories participating in October 2014 national external quality assessment scheme of lymphocyte subsets by flow cytometry tests of National Center for Clinical Laboratory.Relevant information about reference intervals of 5 relative counting items CD3 + (%),CD3 + CD4 + (%),CD3 + CD8 + (%),CD3-CD16 + CD56 + (%) and CD3-CD19 + (%) was collected by a internet-based external quality assessment software systems.Microsoft Excel 2010 and SPSS 19.0 were used to sort out raw data,eliminate unreasonable or incorrect data,and only analyze source distribution,arithmetic average,median,minimum value,maximum value and percentiles (P2.5 and P97.5) of upper and lower limits about healthy adults' reference intervals.Laboratories derived from the highest percentage of source distribution whose reagent and instrument were matching with each other were grouped according to the test systems used and the differences of reference intervals between different systems were compared with Mann-Whitney test.Results For five items collected,in the clinical laboratories who accepted statistical analysis,respectively 39.32% (81/ 206),37.44% (79/211),37.68% (78/207),37.11% (72/194),36.98% (71/192) of them had verified the reference intervals they used.The top three sources of reference intervals were instructions of reagent and instrument manufactures (49.70%-52.54%),calculations by laboratories themselves (18.64%-20.00%),and calculations by other laboratories (14.12%-15.43%).The arithmetic averages and medians of upper and lower limits about every item were relatively close.But the minimum and maximum values of upper and lower limits of certain items had moderate differences.As Mann-Whitney test later showed,all items with the P values of upper and lower limits between different test systems,except for the lower limit of CD3 + CD4 + (%) (P value is 0.052) and the upper limit of CD3-CD19 + (%) (P value is 0.117),were lower than 0.05 which meant an existing statistical difference.Conclusions The sources of lymphocyte subsets by flow cytometry tests in all Chinese clinical laboratories were different and the instructions of reagent and instrument had the highest percentage,but the reference intervals among differenttest systems had statistically significance.
5.Establishment of a hypoxia/reoxygenation model of H9 c2 cell using hypoxia/anoxic workstation
Qianwen CHU ; Weiqiu LI ; Shishi LU ; Danmei HUANG ; Yanmei ZHANG
Chinese Journal of Biochemical Pharmaceutics 2015;(11):11-14
Objective To investigate optimal method of establishing hypoxia/reoxygenation(H/R) model of H9c2 cell by using hypoxia/anoxic workstation under different conditions in hypoxia.Methods H9c2 cell was placed into hypoxia/anoxic workstation and simultaneously cultured with complete medium, glucose-free DMEM and acidic hypoxic solution for 1,2,4,6 and 8 h respectively, and then reoxygenated with complete medium for 1 h in normoxic incubator.The level of ROS was measured by flow cytometry.The cell viability was detected by MTT assay.The cellular morphology was observed by inverted microscope.Results With the extension of cell hypoxia time, there were no significant differences in the ROS level and cell viability in complete medium-and glucose-free DMEM-treated H/R groups compared with control group(P<0.05).There was no obvious morphologic change observed with inverted microscope, either.Nevertheless, when H9c2 cells were treated with acidic hypoxic solution in hypoxia, the ROS level continuously increased and the cell viability decreased with the extension of cell hypoxia time ( P<0.01 ).Since H:1 h/R:1 h, some of the cells shrunk and a few necrotic cells floated in the media under the inverted microscope , and the damage was aggravated with the extension of hypoxia time.After the cells were exposed in hypoxia for 8 h, they wrinkled to be round and a large number of floating necrotic cells were observed.When the cells were reoxygenated for 1 h, the cytomembrane was not smooth and there were still a few necrotic cells floating in culture dish .Conclusion The H9c2 cell H/R model with good repeatability can be established successfully by using hypoxia/anoxic workstation combining with acidic hypoxic solution.
6.Further Understanding of Measurement Uncertainty in Clinical Laboratory Medicine
Shishi ZHANG ; Wei WANG ; Haijian ZHAO ; Zhiguo WANG
Journal of Modern Laboratory Medicine 2017;32(2):1-4,9
In clinical laboratory medicine,measurement uncertainty (MU) is a fixed property of testing results in the measuring system.As an important part of ISO 15189,it is necessary for clinical laboratories to determine MU during the period of validation and verification for each measurement procedure and to review MU over time.Now,testing reports provided by clinical laboratories usually do not offer MU,but some clinical laboratories have already estimated MU in their routine work.Estimation andmonitoring of MU can help clinical laboratories offering more accurate results and provide objective tools for clinicians used in result intcrpretatinn.Generally,result interpretation can be achieved by the result comparison with three main comparators,including a previous result from the same patient,a population reference interval and a clinical decision point.The means of true value and the components contributing to the estimation of MU are both different when the com parison is conducted between testing results and different comparators,so the optimum estimation method of MU is accordingly different,which will subsequently affect the MU value and the determination of clinical decisions.Obviously,depending on the actual clinical uses,laboratories can choose appropriate comparators to the result interpretation and the determination of optimum estimation method of MU.For different clinical uses (diagnosis or monitoring) of the same mearurands,the adoption of different estimation methods should be used to acq uire reasonable MU.By interpreting the concept,characteristics,estimation,and uses of MU,as well as explaining how three main comparison methods of results exploit their own traceable chain to get MU,this paper intends to help clinical laboratories get further understanding of the importancc of MU and provide guidance for the MU estimation in routine work.
7.Analysis and Comparison of Reference Intervals of Serum Total Bilirubin and Serum Direct Bilirubin with Upcoming Industry Standards in China
Shishi ZHANG ; Wei WANG ; Haijian ZHAO ; Falin HE ; Kun ZHONG ; Zhiguo WANG
Journal of Modern Laboratory Medicine 2017;32(3):152-156
Objective To analyze the reference intervals of serum total bilirubin (TBIL) and serum direct bilirubin (DBIL) by all Chinese clinical laboratories and make a comparison with the upcoming part 4 of Industry Standard WS/T 404.Methods Relevant information about reference intervals of all clinical laboratories participating in TBIL and DBIL testing items of 2014 national external quality assessment scheme of clinical routine chemistry was collected by a web-based external quality assessment software,including source,grouping,verification,upper and lower limits of reference intervals and instruments,reagents,methods and calibrators used.Microsoft Excel 2010 and SPSS 19.0 were applied to statistical analysis.The comparison between reference intervals used and the upcoming Industry Standard was conducted by the simple mean t test.Laboratories derived from the highest percentage of source distribution whose reagent and instrument were matching with each other were grouped according to the test systems used and the differences of reference intervals between three mainly used test systems and the upcoming Industry Standard were also compared with the single sample mean t test.Results The number of laboratories participated in the investigation about source distribution of reference intervals for TBIL and DBIL was 749 and 709 respectively.For these two items,the highest sources were both instructions of reagent(TBIL 58.08%,DBIL 58.67 %),next were both National Clinical Laboratory Operation Rules (3rd Edition) (TBIL 29.64 %,DBIL 28.91 %),the percentages of other sources were all less than 10%.Besides,there were respectively 379 (50.60%) and 354 (49.93%) laboratories verifying their reference intervals for TBIL and DBIL.The difference of the comparison between reference intervals used and the upcoming Industry Standard had statistical significance (P<0.05).The using reference intervals were narrower than the upcoming Industry Standard for both items.In all laboratories with reference intervals from instructions of reagent,themating laboratories respectively accounted for 41.88% and 41.48%% for item TBIL and DBIL.As the single sample mean t test showed,the comparison of the reference intervals between three mainly used test systems in these mating laboratories and the upcoming Industry Standard had statistical significance (P<0.05),except for the lower limit of DBIL with Beckman test system (P value was 0.068) and the upper limit of DBIL with HITACHI test system (P value was 0.087).Conclusion Currently,the using situation of reference intervals about TBIL and DBIL by all Chinese laboratories was not scientific and rational enough and has significant difference with the upcoming Industry Standard.Should publish the part 4 of Industry Standard WS/T 404 as soon as possible,which would help clinical laboratories establishing suitable reference intervals and promote the standardization of its usage.
8.Clinical study on improving the strength and activity of lumbar spine with Qiang Jin exercises.
Cheng-Zhe ZHANG ; Ling-San HU ; Ye ZHAO ; Min ZHANG ; Hong-Sheng ZHAN ; Wei-An YUAN
China Journal of Orthopaedics and Traumatology 2021;34(10):959-964
OBJECTIVE:
To observe the effect of Qiang Jin exercises on the muscle strength and activity of lumbar spine in patients with lumbar disc herniation.
METHODS:
From March 2016 to September 2017, at the Department of Orthopaedics, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine, a total of 110 subjects were enrolled, and 98 eligible subjects were screened. The subjects were randomized by stratified randomization and divided into experimental group and control group, 49 cases in each group, 25 males and 24 females in the experimental group, 25 males and 24 females in the control group. The experimental group exercised with Qiang Jin exercises, one time each morning and evening, each time10 sets were made;the control group used classic rehabilitation training, training twice a week, and three months was a course of treatment. After 12 weeks of training, the muscle strength and activity of the lumbar spine were evaluated and compared with the muscle strength and activity of the lumbar spine before training.
RESULTS:
The experimental group and the control group had different muscle strength and activity of the lumbar spine before and after treatment (
CONCLUSION
Qiang Jin exercises can effectively improve the muscle strength and activity of the lumbar spine and improve the daily living ability of patients.
China
;
Female
;
Humans
;
Intervertebral Disc Degeneration
;
Intervertebral Disc Displacement
;
Lumbar Vertebrae
;
Lumbosacral Region
;
Male
;
Treatment Outcome
9.Obstructive sleep apnea hypopnea syndrome on the quality of vocal sound
Xiaoyu WANG ; Peng LIN ; Wei WANG ; Jianqun DU ; Shishi XIE ; Xin PENG ; Li LI ; Shengchi ZHANG ; Guiping WANG
Chinese Archives of Otolaryngology-Head and Neck Surgery 2016;23(1):45-48
OBJECTIVE To investigate the effect of obstructive sleep apnea hypopnea syndrome(OSAHS) on the quality of voice. METHODS Electroglottography (EGG) method was used for detecting the vocal cords vibration, waveforms of electroglottography and voice parameters such as Jitter, Shimmer, normalized noise energy (NNE), contact quotient(CQ), contact index (CI), contact quotient perturbation(CQP), contact index perturbation(CIP), and the in 82 OSAHS patients and 53 healthy subjects. The voice parameters were analyzed with Dr.Speech software, RESULTS While in normal pronunciation, the Jitter, Shimmer, NNE, CQP and CIP were (1.037±1.493)%, (5.627±1.872)%, (-16.109±1.719)dB, (2.638±0.633)% and (166.789±30.492)% in 22 mild OSAHS patients, (1.578±0.362)%, (8.478±1.635)%, (-11.517±1.614)dB, (6.043±0.936)% and (255.210±91.224)% in 24 moderate OSAHS patients, and (2.138±1.384)%, (14.888±4.089)%, (-7.677±2.151)dB, (11.749±7.164)% and (431.233±259.266)%in 36 severe OSAHS patients respectively. They were all higher than those in 53 normal subjects as (0.517±0.303)%, (3.299±2.196)%, (-21.933±5.477)dB, (1.322±0.942)% and (58.834±131.849)%. The regularity of vocal fold vibration in all patients with OSAHS was seriously out of whack. EGG waveform was irregular. CONCLUSION The OSAHS patients have structural changes in their upper airway, it will cause non-physiological breathing and lead dry of the vocal cord mucosa and weak elasticity. Their EGG parameters will get higher and vibration will be irregular seriously. We should pay attention to the voice qualities of the OSAHS patients and let them receive treatment as early as possible.
10.Expression of CDK5 and its correlation with peripheral inflammation-related cells and prognosis in colon cancer patients
Qinghua WANG ; Ruihua YIN ; Bin HU ; Bingjing JIANG ; Zhihui DAI ; Wanfen TANG ; Xia ZHANG ; Shishi ZHOU ; Jianfei FU
Chinese Journal of General Surgery 2021;36(10):774-778
Objective:To identify the clinical significance of CDK5 in colon cancer tissues.Methods:Two hundred colon cancer tissues were tested for CDK5 expression by immunohistochemistry on tissue microarrays. The correlation between CDK5 expression and clinicopathological features, prognosis and peripheral inflammation-related cells was analyzed.Results:CDK5 was low expressed in 100 cases (50.0%), and high in another 100 cases (50.0%). Longer time to tumor progression ( P=0.026) and overall survival ( P=0.035) were observed in patients with high CDK5 expression. By multivariate analysis , the expression of CDK5 was an independent risk factor for poor prognosis ( HR=0.45,95% CI: 0.21-0.99, P=0.049). The expression of CDK5 was not related to the counts of white blood cells and neutrophils ( P>0.05). Prognosis of patients with a positive lymph node ratio less than 0.15 was significantly better than that of patients with a higher lymph node ratio ( P<0.001). Conclusions:Patients with low CDK5 expression have poor prognosis, and CDK5 expression is not related to the counts of peripheral white blood cells and neutrophils.