1.Study of the influence of uniform transverse magnetic field on the dose distribution of high energy electron beam using Monte Carlo method.
Shihu YOU ; Yun XU ; Zhangwen WU ; Qing HOU ; Chengjun GUO
Journal of Biomedical Engineering 2014;31(6):1350-1354
In the present work, Monte Carlo simulations were employed to study the characteristics of the dose distribution of high energy electron beam in the presence of uniform transverse magnetic field. The simulations carried out the transport processes of the 30 MeV electron beam in the homogeneous water phantom with different magnetic field. It was found that the dose distribution of the 30 MeV electron beam had changed significantly because of the magnetic field. The result showed that the range of the electron beam was decreased obviously and it formed a very high dose peak at the end of the range, and the ratio of maximum dose to the dose of the surface was greatly increased. The results of this study demonstrated that we could change the depth dose distribution of electron beam which is analogous to the heavy ion by modulating the energy of the electron and magnetic field. It means that using magnetic fields in conjunction with electron radiation therapy has great application prospect, but it also has brought new challenges for the research of dose algorithm.
Algorithms
;
Electrons
;
Humans
;
Magnetic Fields
;
Monte Carlo Method
;
Phantoms, Imaging
;
Radiation Dosage
2.Effects of gantry acceleration limitations on VMAT plans
Haojia ZHANG ; Shihu YOU ; Haijie JIN ; Yi ZHANG ; Yuanqiang LUO ; Zhiyong WANG ; Congfeng XU ; Jiaying GAN ; Yinxiang HU
Chinese Journal of Radiological Medicine and Protection 2021;41(9):659-664
Objective:To study the effects of gantry acceleration limitations of a linear accelerator (linac) on the dosimetry of volumetric modulated arc therapy (VMAT) plans, machine efficiency, and dose verification result of VMAT plans and to explore the optimal selection of gantry motion models in the Pinnacle treatment planning system.Methods:Ten cases of nasopharyngeal carcinoma, non-small cell lung cancer, sigmoid adenocarcinoma with retroperitoneal lymph node metastasis, and invasive ductal carcinoma of the breast were each selected for this study. Then two models were set up in the Pinnacle v9.10 treatment planning system, namely the one allowing gantry acceleration and the one limiting gantry acceleration. The same field arrangement, optimized target parameters, and optimized weights of VMAT plans were adopted in the two models, in order to analyze the dosimetric variations in targets and organs at risk (OARs) and compare the differences in treatment time and gamma passing rates.Results:The treatment time of the enrolled patients under the model allowing gantry acceleration was significantly lower than that of the patients under the model limiting gantry acceleration was adopted ( t=-6.751, -0.209, -19.523, -28.999; P< 0.05) and decreased by 15.27%, 18.07%, 19.71%, and 28.75%, respectively. Meanwhile, the conformity and uniformity of target areas were affected, while there was no statistical significance in the gamma passing rates in the validation of VMAT plans ( P>0.05). For the cases of nasopharyngeal carcinoma (NPC), the maximum dose to brainstem PRV increased by 1.25%. For the cases of lung cancer, the maximum dose to the spinal cord and lung V20 increased by 1.19% and 1.21%, respectively, while lung V5 decreased by 1.21%. For the cases of sigmoid adenocarcinoma with retroperitoneal lymph node metastasis, the mean doses to bilateral kidneys, livers, small intestine, and colon all increased. For the cases of breast cancer, lung V10 on the opposite side of cancer increased by 1.66% and the mean dose to the lungs on the same side of cancer decreased by 7.45%. Conclusions:The model allowing gantry acceleration allows the treatment time to be significantly shortened and the treatment efficiency improved. Although this model had the shortcomings such as affecting the conformity and uniformity of target areas to a certain extent and increasing the doses to some OARs, clinical requirements for dosimetry were still met. Therefore, it is recommended to use the model allowing gantry acceleration in the Pinnacle planning system.