1.Effects of various health management on pre-diabetics
Ping ZHANG ; Shihao WANG ; Yahping LIU ; Hong SHI ; Lin YIN
Chinese Journal of Health Management 2012;06(1):36-40
ObjectiveTo explore the effects of different health management on adults with prediabetes.MethodsA total of 1182 pre-diabetics were enrolled in this prospective observation study and assigned to one-by-one interview group,in situ education group,communicative interview group and control group.Three intervention groups received life style intervention ( including health education and risk factor control) for 2 years.Analysis ofvariance,x2 test or q test were used for data analysis.ResultsAfteryear intervention,fasting plasma glucose (FPG)and 2 h plasma glucose of the intervention groups were significantly decreased ( P < 0.05 ).FPG of the one-by-one interview group and the in situ education group was significantly lower than that of the communicative interview group at 6 months ( P < 0.05 ). At 24months,FPG of the one-by-one interview group was lower than that of the in situ education group (P <0.05).The percentage of participants who showed appropriate blood glucose control was increased in the intervention groups. In addition,blood pressure,triglyceride,cholesterol,creatinine and body weight of those in the intervened groups were significantly improved compared with the control group ( all P < 0.05 ),although electrocardiogram results and arteriosclerosisshowed nosignificant changes(P > 0.05 ).Conclusion Health management may contribute to life style change and hypertension control of prediabetics.Furthermore,in situ education may be the most effective life style interventions.
2.Evaluation of PREVI Isola Automated Plate Streaker
Wenjing LIU ; Xiuli XIE ; Hongmei SONG ; Shihao LIU ; Qiwen YANG ; Yingchun XU
Journal of Modern Laboratory Medicine 2016;(1):108-111
Objective To evaluate the characteristics of the PREVI Isola automated plate streaker (bioMérieux,SA).Methods 80 respiratory tract specimens,70 sterile fluids,52 stools,69 swabs,12 cerebrospinal fluids and 80 urines were collected in Peking Union Medicd College Hospital.Specimens were processed with manual streaking and PREVI Isola system.PREVI Isola system were evaluated comparing to the manual streaking.The quality of results were analyzed by SPSS 16.0, doing Wilcoxon’s Sign Rank Test for the results of finally isolated species,overall numbers of isolated colonies and semi-quantita-tive of the species were both isolated by the two methods.Results PREVI Isola system was highly automatic,which could select the right plates and stake the bar code on the back of the plate indicating the type of the agar and inoculation time, PREVI Isola system could accurately absorb the liquid specimen and use a novel comb streaking procedure for processing of fluid specimens on standard agar plates,like 17 inoculating loops work together.It also had a good reproducibility.The quali-ty of PREVI Isola system results:As to the finally isolated species,there was significant statistical difference between PREVI Isola system and manual streaking method in respiratory tract and stools specimen,there were more species isolated by manual streaking method than PREVI Isola system.There were no differences between the two methods for the other of specimen types.As to the amount of pure clones of the species were both isolated by the two methods,there were significant statistical differences between the two methods for respiratory tract,sterile fluid and stool specimens.The amount of clones isolated by PREVI Isola system was more than manual streaking method.In semi-quantitative results,there were significant statistical differences between the two methods for respiratory tract and urine specimen,Species had wider distribution of PREVI Isola system than manual streaking method.Inoculation efficiency:if the batch of specimen type was simple (mainly the urine and so on),using the same plates,PREVI Isola system was more efficient than manual streaking method.Howev-er,if the batch of specimen type was complicated,manual method was high-performance.Besides,not all specimen type could be inoculated by PREVI Isola system,such as cerebrospinal fluid,catheter and tissues.Conclusion If the lab had simple specimen type,or utilize the specimen type using the same agar plates to be inoculated together,PREVI Isola system belongs to a good performance automated plate streaker.
3.Current quality management situation and administration countermeasure study of enterprises marketing corneal contact lens.
Yungui LIU ; Ying YAO ; Shihao SHANGGUAN ; Qun GU ; Wuming GAO ; Yaoshui CHEN
Chinese Journal of Medical Instrumentation 2014;38(3):213-215
OBJECTIVEStudy the current quality management situation of enterprises marketing corneal contact lens via systemic investigations and explore effective administration countermeasures in the future.
METHODSThe quality management indicators of sixty-two corneal contact lens marketing enterprises in Xuhui district of Shanghai were systematically investigated and enterprises of different operation models was compared and analyzed.
RESULTSWholesale enterprises and retail chain enterprises are apparently better than independent enterprises almost in all facets.
CONCLUSIONFacilitate market accession of corneal contact lens marketing enterprises, encourage the business model of retail chain, enhance supervision of corneal contact lens marketing enterprises, especially independent franchisors.
Contact Lenses ; economics ; Marketing ; Materials Management, Hospital
4.An investigation of ionizing radiation dose in a manufacturing enterprise of ion-absorbing type rare earth ore
Wanfeng ZHANG ; Shihao TANG ; Qiang TAN ; Yimin LIU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2016;34(8):620-622
Objective To investigate radioactive source term dose monitoring and estimation results in a manufacturing enterprise of ion-absorbing type rare earth ore and the possible ionizing radiation dose received by its workers.Methods Ionizing radiation monitoring data of the posts in the control area and supervised area of workplace were collected,and the annual average effective dose directly estimated or estimated using formulas was evaluated and analyzed.Results In the control area and supervised area of the workplace for this rare earth ore,α surface contamination activity had a maximum value of 0.35 Bq/cm2 and a minimum value of 0.01 Bq/cm2;β radioactive surface contamination activity had a maximum value of 18.8 Bq/cm2 and a minimum value of 0.22 Bq/cm2.In 14 monitoring points in the workplace,the maximum value of the annual average effective dose of occupational exposure was 1.641 mSv/a,which did not exceed the authorized limit for workers (5 mSv/a),but exceeded the authorized limit for general personnel (0.25 mSv/a).The radionuclide specific activity of ionic mixed rare earth oxides was determined to be 0.9.Conclusion The annual average effective dose of occupational exposure in this enterprise does not exceed the authorized limit for workers,but it exceeds the authorized limit for general personnel.We should pay attention to the focus of the radiation process,especially for public works radiation.
5.An investigation of ionizing radiation dose in a manufacturing enterprise of ion-absorbing type rare earth ore
Wanfeng ZHANG ; Shihao TANG ; Qiang TAN ; Yimin LIU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2016;34(8):620-622
Objective To investigate radioactive source term dose monitoring and estimation results in a manufacturing enterprise of ion-absorbing type rare earth ore and the possible ionizing radiation dose received by its workers.Methods Ionizing radiation monitoring data of the posts in the control area and supervised area of workplace were collected,and the annual average effective dose directly estimated or estimated using formulas was evaluated and analyzed.Results In the control area and supervised area of the workplace for this rare earth ore,α surface contamination activity had a maximum value of 0.35 Bq/cm2 and a minimum value of 0.01 Bq/cm2;β radioactive surface contamination activity had a maximum value of 18.8 Bq/cm2 and a minimum value of 0.22 Bq/cm2.In 14 monitoring points in the workplace,the maximum value of the annual average effective dose of occupational exposure was 1.641 mSv/a,which did not exceed the authorized limit for workers (5 mSv/a),but exceeded the authorized limit for general personnel (0.25 mSv/a).The radionuclide specific activity of ionic mixed rare earth oxides was determined to be 0.9.Conclusion The annual average effective dose of occupational exposure in this enterprise does not exceed the authorized limit for workers,but it exceeds the authorized limit for general personnel.We should pay attention to the focus of the radiation process,especially for public works radiation.
6.Research progress in the catalytic rearrangement reaction of benzyl phenyl ethers
Chongqing WANG ; Ningning MA ; Chao YANG ; Shihao LIU ; Ju ZHU ; Canhui ZHENG
Journal of Pharmaceutical Practice 2015;(6):486-489
The rearrangement reaction of benzyl phenyl ethers (BPE) plays an important role in the organic chemistry and drug synthesis .This paper briefly reviewed the rearrangement reaction and its possible mechanism in various catalytic sys-tems ,such as trifluoroacetic acid ,phosphotungstic acid ,cyclodextrin ,molten tin and aluminium bromide .
7. Study on determination of ethylal in workplace air by gas chromatography
Weijie LING ; Weifeng RONG ; Peixian CHEN ; Shihao TANG ; Shaoxiong XU ; Hai ZHANG ; Yimin LIU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2018;36(6):471-473
Objective:
A solvent desorption-gas chromatography method for determination of ethylal in workplace air has been established.
Methods:
Ethylal in workplace air was collected by activated carbon tube and desorbed with carbon disulfide, and the desorption solutions were analysed by capillary column GC with FID detector.
Results:
The method presented a good linearity in the range of 0.87~34 800.00 mg/L of ethylal in the standard solution, with the correlation coefficient being
8.Efficacy of improved skin expanding method on patients with arm infusion port
Jing HE ; Yanli SU ; Wenxia WANG ; Na ZHANG ; Na WANG ; Shihao LIU
Chinese Journal of Clinical Nutrition 2020;28(1):51-55
Objective:To explore the efficacy and safety of improved skin expanding method on patients with arm infusion port.Methods:Clinical data of 100 patients with gynecological malignant tumor receiving adjuvant chemotherapy was retrospectively analyzed, including 50 patients treated by traditional way of expanding skin(transverse and micro intubation sheath inserted into blood vessels) and 50 patients treated by modified skin expanding method, namely making an incision with both depth and length of 0.5 cm which tilting 45° from the thread toward the port. The indexes as planting time, smooth operation, incidence of secondary enlargement, patient satisfaction, port moving time and incidence of postoperative complications were compared and analyzed between the two groups.Result:Modified skin expanding method was superior to traditional skin expanding way in planting time, smooth operation, incidence of secondary enlargement, patient satisfaction, port moving time and incidence of postoperative complications.Conclusions:Compared with the traditional way of expanding skin, modified skin expanding method can adjust catheter malposition caused by connecting with the port and send the catheter back into blood vessel at the incision maintaining the smooth of the catheter. Can make the operation well going increasing the efficiency of implantation of the upper arm infusion port. Can avoid the adverse consequences from the straddle of blood vessel by catheter and port in the tunnel after the catheter indwelling, which greatly enhances the safety of patients during infusion port application period.
9.Current Quality Management Situation and Administration Countermeasure Study of Enterprises Marketing Corneal Contact Lens
Yungui LIU ; Ying YAO ; Shihao SHANGGUAN ; Qun GU ; Wuming GAO ; Yaoshui CHEN
Chinese Journal of Medical Instrumentation 2014;(3):213-215
Objective Study the current quality management situation of enterprises marketing corneal contact lens via systemic investigations and explore effective administration countermeasures in the future. Methods The quality management indicators of sixty-two corneal contact lens marketing enterprises in Xuhui district of Shanghai were systematical y investigated and enterprises of different operation models was compared and analyzed. Results Wholesale enterprises and retail chain enterprises are apparently better than independent enterprises almost in al facets. Conclusion Facilitate market accession of corneal contact lens marketing enterprises, encourage the business model of retail chain, enhance supervision of corneal contact lens marketing enterprises, especially independent franchisors.
10.Research progress of pH-responsive drug delivery systems in cancer immunotherapy
Shihao WANG ; Lifeng LIU ; Yang DING ; Suxin LI
Journal of China Pharmaceutical University 2024;55(4):522-529
Abstract: Cancer immunotherapy, which is an attractive strategy harnessing the host's own immune system to remove tumor cells, has been widely used in clinical practice, yet with low response rate and immune-related adverse events. Unlike traditional chemotherapy, the targets of immunotherapy exhibit high spatial heterogeneity and are distributed in different cell types or secondary organelles, resulting in off-target and on-target toxicity, which greatly reduces the efficacy and safety of treatment. Due to the altered metabolic level, tumor tissues often display a lower pH than normal tissues. In addition, the endocytosis pathway is accompanied by continuous pumping of protons. Therefore, the variation of environmental pH values could serve as an ideal stimulus for precise drug delivery and release. In recent years, pH-responsive materials (e.g., polymers, biomacromolecules, lipid nanoparticles, biofilm, inorganic nanoparticles, and metal-organic frameworks) have been widely investigated in the field of cancer immunotherapy. This paper summarizes recent strategies of pH-responsive drug delivery systems based on different types of carriers, aiming to provide some reference for the design of next generation of tumor-targeting formulations in cancer immunotherapy.