1.Building and adminiatration of research-based central lab in the hospital
Shida HE ; Yanchuan WU ; Rong WIANG ; Ling CHEN ; Jie SU ; Xiujuan DING
Chinese Journal of Hospital Administration 2010;26(4):300-302
Importance of central laboratories in hospitals is rising sharply as they provide laboratory support to hospital development in its science researches. The paper introduced the mission and features of the central lab of the hospital, as well as its technical personnel makeup, instrumentation, and rules and regulations. Authors prove in the paper that central labs are playing a key role in hospital science research as its research base.
2.A new methodology of DNA polymorphism detection from standard long gun
Xiuqiao YANG ; Lin MIAO ; Hongliang XIE ; Lei HUANG ; Shida SU ; Shunyong PAN ; Faming ZENG ; Dian ZHAI ; Baowen CHENG
Chinese Journal of Forensic Medicine 2017;32(4):385-387,392
Objective A new methodology was established to efficiently obtain the genotype of DNA remained on standard long gun. Methods Direct PCR and silicon membrane method were combined to detect DNA polymorphism of a total of 240 samples at 5 different positions from 48 standard long guns. Results Combining direct PCR and silicon membrane method, we obtained full DNA profiles in 42 out of 48 standard long guns, with a detection rate up to 87.50%. Conclusion The results demonstrate that the combination of direct PCR and silicon membrane method provide a quick and accurate way to detect DNA polymorphism on the standard long gun.
3.Impact of statistical uncertainty per control point on dose calculation on VMAT for rectum cancer
Weiqiang YE ; Wei ZHANG ; Bo LI ; Chaojun YU ; Zhenzhen WEI ; Shida SU ; Wen QIN ; Dawei ZHANG
The Journal of Practical Medicine 2024;40(19):2685-2689
Objective To investigate the impact of statistical uncertainty per control point(SUpCP)on dose calculation on volumetric modulated arc therapy(VMAT)for rectum cancer,and to analyze the accuracy and efficiency of calculation.Methods 19 patients with rectum cancer undergoing radiotherapy were selected.The initial VMAT plans were generated on Monaco TPS using SUpCP=3,then changed SUpCP in the dose calculation process as follow:10 SUpCPs(1~10)for each patient,and totally190 VMAT dose distributions were obtained.For plan evaluation,Dmax,Dmean,D95%,V50,homogeneity index(HI),conformity index(CI)of the planning target volume(PTV),dissymmetric variations of bladder,small intestine and femoral head,and time calculation(Time)were analyzed.Patient specific quality assurance(PSQA),dose deviation of isocenter(ΔDISO)and passing rate of three-dimensional dose distribution(γ33,γ32,γ22)between calculated and delivered radiation doses were measured.Results AsSUpC increased,Dmax and HI of PTV,Dmax of bladder were increased,but D95%and V50 of PTV,Time,γ32 and γ22 were decreased(P<0.05).Dmax and CI of PTV,Dmean of bladder,Dmax and Dmean of small intestine and femoral head,ΔDISO and γ33 showed no statistical significance(P>0.05).When ΔDISO<1%,gamma passing rate>90%for all VMAT plan.When SUpCP<6,Dmax of PTV<110%of the prescribed dose was obtained;while SUpCP>2,time for dose calculation was less than 5 min.Conclusion For VMAT plan of rectum cancer on Monaco TPS using XVMC algorithm,3%~5%of statistical uncertainty per control point for dose calculation,and 3%2 mm or 2%2 mm gamma criteria for three-dimensional dose verification is recommended.This study provides clinical application basis for precise dose calculation of VMAT plan of rectum cancer.