1.A case report of SARS-CoV-2 encephalitis
Jue SHI ; Jin SHU ; Chen ZHAO ; Meimei CAO ; Yi FU ; Li JIN
Shanghai Journal of Preventive Medicine 2023;35(3):301-303
A patient with SARS-CoV-2 infection was adimitted to Shanghai Shibei hospital of Jing'an District in early 2023. According to the patient's complaits, clinical manifestations, physical symptoms, laboratory examination, radiological image results, plus lumbar puncture, the patient was diagnosed with novel coronavirus encephalitis. The patient was discharged from the hospital after a combined treatment of Chinese and western medicine.
2.Effects of probucol on high glucose-induced specificity protein 1/Keap1/Nrf2/glutamate-cysteine ligase catalytic in the cultured human müller cells
Chenxiang LI ; Shibei AI ; Zhongping CHEN ; Xuxia ZHOU
Chinese Journal of Ocular Fundus Diseases 2019;35(2):187-191
Objective To observe the expression ofprobucol on high glucose-induced specificity protein 1 (SP 1),kelchlike ECH associated protein 1 (Keap 1),NF-E2-related factor 2 (Nrf2) and glutamatecysteine ligase catalytic (GCLC) in the cultured human müller cells and preliminary study the antioxidation of the probucol on müller cells.Methods Primary cultured human müller cells were randomly divided into four groups:normoglycaemia group (5.5 mmol/L glucose),normoglycaemia with probucol group (5.5 mmol/L glucose+100 μmol/L probucol),hyperglycemia group (25.0 mmol/L glucose),hyperglycemia with probucol group (25.0 mmol/L glucose + 100 μmol/L probucol).Immunofluorescence staining was used to assess distribution of SP1,Keapl,Nrf2,GCLC in human Müller cells.SP1,Keapl,Nrf2 and GCLC messenger RNA (mRNA) expression was evaluated by quantitative real-time RT-PCR (qRT-PCR).Independent sample t test was used to compare the data between the two groups.Results All müller cells expressed glutamine synthetase (> 95%),which confirmed the cultured cells in vitro were the purification of generations of müller cells.The expressions of SP 1,Keap 1,Nrf2,and GCLC protein were positive in human müller cells.qRT-PCR indicated that SP1 (t=28.30,P<0.000),Keap1 (t=5.369,P=0.006),and Nrf2 (t=10.59,P=0.001) mRNA in the hyperglycemia group increased obviously compared with the normoglycaemia group;GCLC (t=4.633,P=0.010)mRNA in the hyperglycemia group decreased significantly compared with the normoglycaemia group.However,SP1 (t=12.60,P=0.000) and Keapl (t=4.076,P=0.015) in the hyperglycemia with probucol group decreased significantly compared with the hyperglycemia group;Nrf2 (t=12.90,P=0.000) and GCLC (t=l 5.96,P<0.000)mRNA in the hyperglycemia with probucol group increased obviously compared with with the hyperglycemia group.Conclusion Probucol plays an antioxidant role by inhibiting the expression of SP 1,Keap 1 and upregulating the expression of Nrf2,GCLC in müller cells induced by high glucose.
3.A preliminary study of intravascular ultrasound in carotid arterial stenting
Xianfeng CHEN ; Shibei CUI ; Jin SHI ; Yingqian ZHANG ; Dawei CHEN ; Longsong PIAO
Chinese Journal of Neuromedicine 2017;16(9):881-885
Objective To investigate the significance of intravascular ultrasound (IVUS) in diagnosis and treatment of carotid stenosis.Methods IVUS was performed before and after carotid arterial stenting (CAS) in 12 patients with moderate or severe carotid stenosis,admitted to our hospital from July 2014 to April 2016 and diagnosed by digital subtraction angiography (DSA).The severity of carotid stenosis,expansion and adherence of the stent were observed,respectively.Results DSA indicated 17 vessels having pathological changes,including 4 (23.5%) eccentric lesions and 13 (76.5%) concentric lesions;IVUS indicated 23 vessels having pathological changes,including 13 (56.5%) eccentric lesions and 10 (43.5%) concentric lesions;the rate of eccentric plaque detected by IVUS was significantly higher than that by DSA (P<0.05).The carotid diameter stenosis degree measured by DSA was smaller than the stenosis degree by IVUS (P<0.05).In 4 patients underwent CAS,DSA showed that the residual stenosis was more than 30%,and IVUS showed stent underexpansion or poor adherence;in other 5 patients undewent CAS,IVUS showed poor stent symmetry,however,IVUS showed that the stent expansion,symmetry and adherence became better after the balloon expansion.Conclusion IVUS is useful for evaluation before and after stenting in patients with moderate or severe carotid stenosis.
4.Dose response relationship between elevated blood pressure and body mass index in primary and secondary school students in Shibei District, Qingdao
WANG Chunhui, HU Baocui, REN Zhisheng, CHEN Jian, HE Qianqian
Chinese Journal of School Health 2024;45(8):1181-1185
Objective:
To investigate the doseresponse relationship between the risk of elevated blood pressure and body mass index (BMI) in primary and secondary school students in Shibei District, Qingdao, so as to provide a reference for precise interventions of elevated blood pressure.
Methods:
Statistical analysis was conducted on the health examination data of 92 091 primary and secondary school students in Shibei District, Qingdao, in 2022. Overweight and obesity were assessed using the standards from the Screening for Overweight and Obesity among Schoolaged Children and Adolescents, and blood pressure levels were evaluated using the Reference of Screening for Elevated Blood Pressure among Children and Adolescents Aged 7-18 Years. The relationship between BMI and elevated blood pressure was examined using analysis of variance, Chisquare test, multifactorial Logistic regression, and a combination of restricted cubic spline after data cleaning.
Results:
Based on the standardized scores under different age and gender, BMI was classified into 5 categories. Compared with the group of BMIZ scores 0-<1, the risk of developing high blood pressure gradually decreased with BMIZ scores (OR=0.55, 0.53, P<0.05). Conversely, the risk of developing high blood pressure increased with increasing BMIZ scores (OR=1.90, 3.71, P<0.05). Stratified analyses showed that BMI was positively associated with elevated blood pressure by gender (male, female), age (aged 7-8, 9-11, 12-14, 15-16), and waisttohip ratio (≤0.83, >0.83) (OR=1.18, 1.19, 1.15, 1.22, 1.19, 1.18, 1.19, 1.18, P<0.01). There were multiplicative interactions between BMI and gender, between BMI and age, between BMI and waisttohip ratio (OR=1.53, 1.08, 2.31, P<0.01). Restricted cubic spline analysis showed that as BMI levels increased, the risk of developing elevated blood pressure showed a nonlinear increasing trend in both the 7yearold and the 10 to 16yearold (χ2=27.56, 10.69, 6.10, 27.26, 18.32, 25.71, 10.53, 6.14, P<0.05).
Conclusions
The risk of elevated blood pressure in primary and secondary school students increases with BMI, showing a nonlinear doseresponse relationship. The blood pressure should be monitored regularly, and comprehensive and effective measures should be implemented to control elevated blood pressure in children and adolescents.
5.Establishment and validation of embryo high-quality prediction models based on the third-day 340 nm absorbance embryo culture
Chao ZHOU ; Guangyu YU ; Jiaqi FAN ; Chunmei YU ; Min WU ; Shibei CHEN
Chinese Journal of Tissue Engineering Research 2024;28(7):1050-1056
BACKGROUND:A large number of previous studies have confirmed that a high concentration of metabolites is significantly correlated with embryo quality and clinical outcome,and the theory of silencing embryo development indicates that normally developed embryos maintain a low level of material exchange with the outside world during in vitro culture,while embryos often show abnormal metabolic activity due to stress repair mechanism when DNA damage occurs. OBJECTIVE:To establish and verify an embryo quality prediction model based on the third-day 340 nm absorbance embryo cultures to provide the basis for a more objective and accurate embryo quality assessment. METHODS:269 patients at the Nanxishan Hospital of Guangxi Zhuang Autonomous Region for in vitro fertilization and embryo transplantation from November 2019 to December 2021 were retrospectively analyzed.Among them,on day 3,162 cases who had 873 optimal embryos and 214 high-quality blastocysts were included in the high-quality embryo group.On day 3,107 cases who had 859 non-optimal embryos and 214 non-high-quality blastocysts were included in the non-high-quality embryo group.Lambert-beer law was used to screen out the characteristic wavelength with distinguishing degree between superior and non-superior embryos,analyze its correlation and influence trend with high-quality embryos,and establish the clinical prediction model and validation of absorbance for high-quality and non-high-quality embryos at this wavelength. RESULTS AND CONCLUSION:(1)There was a significant difference in absorbance between high-quality and non-high-quality embryos at 340 nm on day 3(P<0.001),and a negative correlation was found with the formation of high-quality embryos on day 3(r=-0.486,P<0.001).The absorbance of high-quality and non-high-quality blastocyst at 340 nm was significantly different(P<0.05),and was negatively correlated with the formation of high-quality blastocyst(r=-0.642,P<0.001).(2)The optimal cut-off value of absorbance at 340 nm between high-quality and non-high-quality embryos on day 3 was 0.235.The area under the curve was 0.799.Sensitivity was 62.9%.Specificity was 78.0%.Accuracy was 70.5%.The optimum cutoff value of high-quality and non-high-quality blastocysts of absorbance at 340 nm was 0.175.The area under the curve was 0.871.Sensitivity was 74.3%.Specificity was 89.1%.Accuracy was 82.2%.(3)Restricted cubic spline curve analysis showed that when the absorbance of the culture medium at 340 nm was greater than 0.221,there was a significant positive trend on the formation of non-high-quality embryos at day 3,and when the absorbance of the culture medium at 340 nm was greater than 0.160,there was a significant positive trend on the formation of non-high-quality blastocysts.(4)The clinical decision curve and clinical influence curve showed that the absorbance of the culture medium at 340 nm had the maximum clinical net benefit for the prediction models of high-quality embryos and high-quality blastocysts on the third day when the valve probability was 0.18-0.95 and 0.16-1.00,respectively,and the ratio of loss to gain within the valve probability range was always less than 1.It is proven that the prediction model has good efficacy in clinical applications.The results of embryo transfer showed that the absorbance of embryo culture medium at 340 nm in non-pregnant patients was significantly higher than that in clinical pregnancy,biochemical pregnancy and early abortion patients(P<0.05).(5)The high-quality and non-high-quality embryo culture in 340 nm absorbance has a significant difference with correlation.The embryo quality prediction model has a certain clinical value and application effectiveness.The joint embryo morphology evaluation to a certain extent improves the objectivity and accuracy of embryo quality evaluation.
6.Construction and validation of pregnancy prediction model of artificial insemination by husband based on endometrial structure and uterine spiral artery blood flow parameters
Guangyu YU ; Jiaqi FAN ; Shibei CHEN ; Leilei GAO ; Qing YU ; Chao ZHOU ; Chunmei YU ; Zhen JIN
Chinese Journal of Tissue Engineering Research 2024;28(19):3061-3068
BACKGROUND:The impact of the endometrium's structure and spiral artery blood flow parameters on the pregnancy rate of artificial insemination by husband remains unclear.This study identified the independent factors and constructed a prediction model with good clinical application efficacy after calibration of other confounding factors. OBJECTIVE:To construct and validate a clinical pregnancy prediction model for artificial insemination by husband based on endometrial structure and uterine spiral artery blood flow parameters. METHODS:A retrospective analysis was conducted on 1 299 patients who underwent artificial insemination by husband treatment at Changzhou Maternal and Child Health Hospital from January 2017 to January 2021.The non-pregnancy group consisted of 1 182 patients,while the pregnancy group included 117 patients.Out of these patients,93 cases were successfully matched between the pregnancy and non-pregnancy groups using a 1∶1 propensity score matching method.Single-factor and multi-factor analyses were used to screen the endometrial structure and uterine spiral artery blood flow parameters to determine their influence on artificial insemination by husband outcomes.The optimal cutoff value was established for each independent influencing factor through receiver operating curve analysis and their risk trend affecting artificial insemination by husband pregnancy outcomes was analyzed using a restricted cubic spline.The clinical efficacy of this combined forecast model was tested by using clinical decision curve and clinical influence curve methods. RESULTS AND CONCLUSION:(1)There was no statistical significance in non-endometrial factors between the pregnancy group and the non-pregnancy group,and the data had a good balance by propensity score matching(P>0.05).(2)Single-factor analysis identified several subendometrial parameters as significant influencing factors of artificial insemination by husband pregnancy outcomes,including vascularization index,flow index,vascular flow index,resistance index,pulsatility index,maximum systolic velocity/end-diastolic velocity,thickness of average junction zone and maximum junction zone from the basal endometrium to the outer myometrium inner layer(P<0.05).(3)Multivariate logistic regression analysis revealed that thickness of average junction zone,pulsatility index,and vascular flow index were independent influencing factors of pregnancy outcomes of artificial insemination by husband,vascular flow index>thickness of average junction zone>pulsatility index.(4)Receiver operating characteristic curve analysis indicated that the area under receiver operating characteristic curve of vascular flow index was 0.704(0.629,0.779),and the optimal cutoff value was 6.26;the area under receiver operating characteristic curve of thickness of average junction zone was 0.660(0.582,0.739),and the optimal cutoff value was 6.38;the area under receiver operating characteristic curve of pulsatility index was 0.642(0.563,0.721),and the optimal cutoff value was 1.18.(5)The restricted cubic spline analysis revealed that artificial insemination by husband pregnancy outcomes were significantly positively affected when the vascular flow index was>6.24 or the thickness of average junction zone was≤6.55 mm,while a negative risk was associated with pulsatility index>1.27.(6)The clinical decision curve and clinical influence curve analyses exhibited that the combined prediction model had the maximum clinical net benefit at the threshold probability value of 0.17-0.93,and the ratio of loss to benefit was consistently less than 1 in the threshold probability range,indicating that the model had good clinical efficacy.(7)It is concluded that after adjusting for other confounding factors outside of the endometrium using propensity score matching and multifactorial logistic regression,the thickness of average junction zone,pulsatility index and vascular flow index were independent factors that influenced pregnancy outcomes of artificial insemination by husband.Through determining their optimal cutoff values and assessing their risk trends,it was confirmed that the combined prediction model had good predictive value and clinical efficacy.