1.Status, Challenges, and Prospects of Treating Chronic Atrophic Gastritis by Chinese Medical Diagnosis and Treatment.
Wei WEI ; Yang YANG ; Hai-xia SHI
Chinese Journal of Integrated Traditional and Western Medicine 2015;35(12):1424-1426
Chronic atrophic gastritis (CAG), a chronic disease of the digestive system resulting from multi-pathogenic factors, is precancerous state of gastric cancer. Authors reviewed the current situation of Chinese medical diagnosis and treatment of CAG, and looked forward to its prospect by combining with their own clinical experience and scientific researches.
Chronic Disease
;
Gastritis, Atrophic
;
diagnosis
;
therapy
;
Humans
;
Medicine, Chinese Traditional
;
Precancerous Conditions
;
Stomach Neoplasms
2.T lymphocytes in pleural effusion.
Chinese Medical Journal 2008;121(7):579-580
3.Establishment of culture system of Silybum marianum hairy roots and determination of silybin.
Shu-Li ZHANG ; Tian-Zhu ZHANG ; Shi-Hai YANG
China Journal of Chinese Materia Medica 2014;39(11):2005-2010
This research uses six Agrobacterium rhizogenes R1601, R15384, R1000, A4, R1025 and R1 to infect silymarin explants to induce hairy roots and silibin. All of the six A. rhizogenes can induce Silybum marianum to generate hairy roots and the A. rhizogene A4 shows comparatively high infection on the plant. This research determines the condition to induce silymarin hairy roots by the factors of infection time, pre-culturing, co-culturing and pH value. The fact that MS liquid medium fits the proliferation of silymarin hairy roots is determined. Through PCR molecular identification, it can be seen that the DNA plasmids in the A. rhizogenes are successfully integrated into the genome of transformed roots. Using liquid chromatography, it is determined that the silibin content in silymarin hairy roots is 2.5 times that in the plant In this research, the silymarin hairy roots culturing system is established, which lays a foundation for the study of culturing silymarin hairy roots and producing silibin.
Agrobacterium
;
genetics
;
physiology
;
Cell Culture Techniques
;
methods
;
Milk Thistle
;
chemistry
;
genetics
;
growth & development
;
microbiology
;
Plant Roots
;
chemistry
;
genetics
;
growth & development
;
microbiology
;
Silymarin
;
analysis
;
Transformation, Genetic
4.Research progress of effective components of Astragalus on prevention and treatment of organ fibrosis
Shi-fen LI ; Ruo-xuan YANG ; Jian SUN ; Hai-hai LIANG
Acta Pharmaceutica Sinica 2023;58(8):2168-2179
Astragalus, which was first documented in Shennong Bencao Jing, is the dried root of
5.Research progress of Chinese herbal medicine raw materials in cosmetics.
Yan-jun XIE ; Wei-jun KONG ; Mei-hua YANG ; Shi-hai YANG
China Journal of Chinese Materia Medica 2015;40(20):3925-3931
Advocating green, nature, environmental protection, safety and the pursuit of efficacy are the trends of cosmetics in the world. In recent years, more and more Chinese herbal extracts with mild, high safety and small irritation are applied to cosmetics as the natural additives. This has become a new hot spot. The recent application advances of Chinese medicine raw materials in cosmetics are overviewed according to their main functions. This review will provide useful references for the future development and application of Chinese medicinal herbs cosmetics.
Animals
;
Biomedical Research
;
trends
;
Consumer Product Safety
;
Cosmetics
;
analysis
;
Drugs, Chinese Herbal
;
analysis
;
Humans
6.Anatomic characteristics of the vessels in the spermatic cord of the varicocele patient: A laparoscopic study.
Bin YANG ; Pu WANG ; Hong-jun LI ; Hai WANG ; Su YAN ; Shi-xiu SHAO
National Journal of Andrology 2016;22(5):406-410
OBJECTIVETo study the numbers and locations of spermatic veins, testicular arteries, and lymphatic vessels in the spermatic cord of the varicocele patient under the laparoscope.
METHODSFifty-seven varicocele patients received laparoscopic ligation of spermatic veins, during which we recorded the numbers and observed the locations of spermatic veins, testicular arteries, and spermatic lymphatic vessels.
RESULTSDuring the surgery, we identified 3.3 ± 1.2 spermatic veins, 1.4 ± 0.9 testicular arteries, and 4.3 ± 1.1 spermatic lymphatic vessels. No statistically significant differences were observed between the two side in the numbers of the spermatic veins, testicular arteries and spermatic lymphatic vessels (P > 0.05). The testicular arteries were seen on the exterior of the spermatic veins and winding around them, while the spermatic lymphatic vessels mostly between the veins.
CONCLUSIONThe spermatic veins, testicular arteries, and lymphatic vessels in the spermatic cord of the varicocele patient have their specific anatomic characteristics. Laparoscopic identification of these vessels may contribute to the surgical treatment of varicocele.
Arteries ; anatomy & histology ; Humans ; Laparoscopy ; Ligation ; Male ; Spermatic Cord ; anatomy & histology ; Testis ; Varicocele ; pathology ; Veins ; anatomy & histology
7.Placement of a Long Intestinal Tube in Patients with Early Postoperative Small Bowel Obstruction under Fluoroscopic Guidance.
Zhi-wei WANG ; Xiao-guang LI ; Jie PAN ; Ning YANG ; Hai-feng SHI ; Zheng-yu JIN
Chinese Medical Sciences Journal 2015;30(3):156-161
OBJECTIVETo investigate the placement of a long tube into the small intestine under fluoroscopic guidance and to evaluate its decompression effect on early postoperative small bowel obstruction (EPSBO).
METHODSFifty-four patients with EPSBO requiring decompression between April 2010 and July 2014 were enrolled in the study. Insertion of a long tube was guided by fluoroscopy. We first used the guide wire to pass the pylorus and then used the 10 Fr feeding tube as an exchangeable tube to put the superstiff wire into the duodenum. Finally the long tube could be passed over the guide wire through the pylorus into the intestine. The total procedure time, the radiation exposure time, and the incidence of complications were evaluated.
RESULTSThe long tubes passed into the jejunum on initial insertion for all patients, so the success rate of this technique was 100%. The long tube was inserted into ileum in 18 patients. The mean total procedure time was 34.4 ± 8.6 minutes, and the mean radiation exposure time 18.9 ± 6.8 minutes. A total of 47 patients (87%) experienced full recovery following long-tube decompression and without the need for surgical intervention.
CONCLUSIONSUsing the wire-exchange technique, it is easy to place a long tube into the small bowel under fluoroscopic guidance. This decompression method is safe and effective for management of EPSBO.
Adult ; Aged ; Decompression, Surgical ; methods ; Female ; Fluoroscopy ; Humans ; Intestinal Obstruction ; surgery ; Male ; Middle Aged ; Postoperative Complications ; surgery ; Retrospective Studies
8.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
9.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
10.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.