1.Interferon γ promotes terminal erythroid differentiation
Shenshen CUI ; Xuemin XIE ; Nanyu WANG ; Xiang Lü
Basic & Clinical Medicine 2017;37(7):963-969
Objective To study the effects of interferon γ(IFN-γ) on terminal erythroid differentiation.Methods RT-qPCR was used to detect the expression of IFN-γ receptors during erythroid differentiation of K562 induced by hemin.Both hemin-induced K562 cells and human umbilical cord CD34+ cell derived primary erythroid cells were treated with IFN-γ.Erythroid differentiation of the cells was evaluated using RT-qPCR to detect the mRNA level of erythroid specific surface markers CD71 and CD235a,and benzidine staining assay was applied to explore the change of hemoglobin expression.Results The expression of IFN-γ receptors in K562 cells decreased and climbed up again after reaching the lowest point at 48 h of hemin induction.IFN-γ treatment increased CD71 and CD235a expression in both hemin-induced K562 cells and the later stage (E15D) primary erythroid cells.Benzidine staining showing increased globin protein expression in hemin-induced K562 cells after IFN-γstimulation.Furthermore,our results indicated that IFN-γ promoted hemin-induced K562 erythroid differentiation in a time dependent manner.Mechanistically,the results showed that IFN-γ treatment stimulated the expression of erythroid transcription factors NFE2,which was critically for erythroid maturation.Conclusions IFN-γaccelerates terminal erythroid differentiation in hemin-induced K562 cells and human umbilical cord CD34+ derived primary erythroid cells.
2.Preliminary application of 3D printing individualized plastic guide plate in the treatment of pelvic and acetabular fracture
Shenshen HAO ; Zhibin LIU ; Fei WANG ; Yanxiong LIU ; Yanfeng WANG ; Bowen WANG ; Xinhao CAO ; Xiaowei XUE
Clinical Medicine of China 2018;34(1):20-25
Objective To introduce the application of 3D printing individualized plastic guide plate in the treatment of pelvic and acetabular fracture and to evaluate its application value.Methods From June 2016 to April 2017,the clinical data of eleven adult patients with pelvic and acetabular fracture was analyzed retrospectively.The pelvic CT scan was performed before operation to obtain the original data.Three-dimensional reconstruction performed by mimics 17.0 software with the data and the fracture reduction performed on the software.3D printing individualized plastic guide plate was designed and made to guide the pre-implantation plate bending and shaping.The pre implantation plate bending was completed according to the plastic guide.Postoperative Matta imaging score was used to evaluate fracture reduction,while the function of the hip joint was assessed by the Harris scores.Results All the operations were successfully completed.There were no adverse complications during or after the operation.Anatomical reduction was performed in 10 cases and functional reduction in 1 case.The excellent and good rate of Matta scores was 90.9%,excellent in 7 cases,good in 3 cases,fair in 1 case and no poor case.The excellent rate of Harris scores was 81.8%,excellent in 6 cases, good in 3 cases,fair in 2 cases and no poor case.Conclusion In the treatment of pelvic and acetabular fracture,the application of 3D printing individualized plastic guide plate may not only make mode simple and feasible and save time and materials,but also simplify the operation,reduce the difficulty of operation and hold satisfactory clinical effect.
3.Value of 3D printing technique in the treatment of adult displaced clavicle fracture
Shenshen HAO ; Zhibin LIU ; Fei WANG ; Yanxiong LIU ; Jun LIU ; Yongjin HE
Clinical Medicine of China 2017;33(10):873-877
Objective To investigate the clinical value of 3D printing technique in the treatment of adult displaced clavicle fracture.Methods The clinical data of forty adult patients with displaced clavicle fracture treated in Yan' an University Affiliated Hospital from January 2016 to December 2016 were retrospectively collected.According to different surgical methods,the patients were divided into group A and group B,with 20 cases in each group.The group A received the CT scan of the uninjured lateral clavicle before operation to obtain the original data.The mimics 17.0 software was used to perform 3D reconstruction and to generate the affected side mirror model.The 3D printer was introduced to print the affected mirror model.According to the model of preoperative planning,minimally invasive surgery was performed under model guidance.The group B(20 cases)was underwent minimally invasive surgery via conventional C arm fluoroscopy.The operation time,blood loss,fluoroscopy times and postoperative hospital stay in the two groups were recorded.The VAS scores of shoulder joint pain and Neer score of shoulder joint function at 3 days after operation and the last follow-up were recorded.Results All patients received postoperative follow-up for nearly 6 months.The operation time of the two groups were(35.8±11.6)min and(50.1+15.5)min(t=3.303,P=0.002),the intraoperative blood loss were(38.4±9.3)ml and(60.3±10.2)ml(t=7.095,P=0.000), respectively,the fluoroscopy times of the two groups were(5.2±1.6)times and(9.7±2.1)times(t=7.622,P=0.000)respectively,the postoperative hospitalization stay were(6.7±0.5)d and(7±0.6)d(t=1.717,P=0.093),the differences were statistically different.The VAS scores of shoulder joint pain and Neer score of shoulder joint function at 3 days after operation and the last follow-up in both two groups were improved significantly than those in preoperative(P<0.05),while there were no significant differences in the two scores between the two groups(P>0.05).Conclusion 3D printing technique assisting minimally invasive surgery for displaced clavicle fractures in adults has the advantages of shorter operation time,less intraoperative blood loss and less fluoroscopy.The clinical follow-up Results are satisfactory.
4.Preliminary application of 3D printing navigation template in the screw insertion of the suprapubic fracture
Fei WANG ; Shenshen HAO ; Zhibin LIU ; Xiaona JI ; Changhong LI ; Yongjin HE ; Yanxiong LIU ; Jun LIU
Clinical Medicine of China 2019;35(2):107-110
Objective To introduce the method of using hollow pull screw insertion for the suprapubic fracture with 3D printing navigation template and to evaluate its clinical effect.Methods From March 2016 to August 2017,eighteen cases of suprapubic ramus fractures treated with hollow lag screw fixation in the Department of Orthopedics of Yanan University Affiliated Hospital were retrospectively collected was collected.Before operation,the thin slice CT scan of pelvis was used to get raw data,and the mimics17.0 software was used to reconstruction the model,to design and make the personalized navigation template assisting the suprapubic fractures surgery.The navigation template was printed out pre-operatively,and the nail was inserted via the assisted by the template intra-operatively.After the operation,the fracture reduction was evaluated by Matta imaging scores and the pelvis function was evaluated by Majeed scores.Results All the operations were successfully completed.The Matta scores were excellent in 11 cases,good in 6 cases,and fair in 1 case.The Majeed scores were excellent in 13 cases,good in 3 cases,and fair in 2 cases.Conclusion 3D Printing navigation template assisted the placement of the hollow screw on the suprapubic fracture could provide personalized treatment,reduce the difficulty of operation and satisfy the clinical effect.
5.Clinical effect of vitamin E in treatment of nonalcoholic fatty liver disease in children: A Meta-analysis
Shenshen LIU ; Yiqing XING ; Ning WANG ; Qiaoling YU ; Leping ZENG
Journal of Clinical Hepatology 2020;36(7):1545-1550
ObjectiveTo investigate the clinical effect of vitamin E in the treatment of nonalcoholic fatty liver disease (NAFLD) in children. MethodsPubMed, Web of Science, The Cochran Library, Embase, OVID/NEJM, CNKI, and Wanfang Data were searched for the articles on vitamin E in the treatment of NAFLD in children published up to December 2019. The data of 8 parameters were analyzed, i.e., body mass index (BMI), liver enzymes [alanine aminotransferase (ALT) and aspartate aminotransferase (AST)], blood lipid levels [triglyceride (TG), total cholesterol (TC), low-density lipoprotein (LDL), and high-density lipoprotein (HDL)], and remission rate of hepatic steatosis. RevMan 5.3 was used to perform a Meta-analysis. Continuous variables were analyzed by standardized mean difference (SMD) and 95% confidence interval (CI), and the changes after intervention were analyzed; categorical variables were analyzed by risk difference (RD) and 95%CI. A fixed effects model was used for homogeneous data, and a random effects model was used for heterogeneous data. Funnel plots were used to evaluate publication bias. ResultsA total of 599 articles were retrieved, among which 9 were included in the Meta-analysis, with 607 subjects in total. Vitamin E significantly improved the level of ALT (SMD = -0.27, 95%CI: -0.48 to -0.06, P=0.01), but it did not improve the levels of BMI (SMD=-0.09, 95%CI: -0.28 to 0.10, P=0.34), AST (SMD=-020, 95%CI: -0.42 to 0.02, P=0.07), TG (SMD=-0.19, 95%CI: -0.51 to 0.12, P=0.22), TCHO (SMD=-0.11, 95%CI: -0.31 to 0.08, P=0.24), HDL (SMD=-0.02, 95%CI: -0.27 to 0.23, P=0.88), LDL (SMD= -0.04, 95%CI: -0.27 to 019, P=072), and the remission rate of hepatic steatosis (RD=0.06, 95%CI: -0.05 to 0.17, P=0.29). ConclusionVitamin E can significantly improve the level of ALT in children with NAFLD and can be considered as an adjuvant drug for clinical treatment.
6.Cognitive frailty of inpatients in Department of Geriatrics and its influencing factors
Weihua WANG ; Jingli KOU ; Tong ZHANG ; Shenshen YANG
Chinese Journal of Modern Nursing 2022;28(3):296-301
Objective:To investigate the cognitive frailty of inpatients in Department of Geriatrics and analyze its influencing factors.Methods:This study was a cross-sectional study. Using the convenient sampling method, inpatients in Department of Geriatrics who were treated in Xuanwu Hospital of Capital Medical University were selected from June 2019 to June 2020. A total of 486 elderly patients who met the inclusion and exclusion criteria completed the questionnaire survey, physical examination and laboratory examination. The FRAIL Frailty Assessment Scale and Mini-Mental State Examination (MMSE) were used to evaluate cognitive frailty. Single factor analysis and Logistic regression were used to analyze the influencing factors of cognitive frailty in elderly inpatients.Results:The age of the survey subjects was (77.99±10.47) years old and the prevalence of cognitive impairment was 37.45% (182/486) . Logistic regression analysis showed that patients with a history of falls within 1 year, drinking, older age, anemia and ADL decline had a higher risk of cognitive impairment ( P<0.05) . Conclusions:The incidence of cognitive frailty is higher in elderly inpatients. Reducing the risk of falls, abstaining from alcohol, improving anemia and intervening to improve the ability of self-care in daily life may help to improve the cognitive frailty of the elderly.
7.Correlation of expression of GDF-8 and Sir4 with myocardial remodeling and cardiac dysfunction in elderly patients with CHF
Shenshen ZHU ; Yanmin HU ; Yuying WANG ; Yaping HUANG ; Zhaoke WU
Chinese Journal of Geriatric Heart Brain and Vessel Diseases 2024;26(11):1287-1291
Objective To explore the expression of serum growth differentiation factor-8(GDF-8)and silent information regulator 4(Sir4)in elderly patients with chronic heart failure(CHF)and their relationship with left ventricular remodeling and cardiac function.Methods A total of 300 CHF patients admitted in our hospital from Jan 2021 to Dec 2023 were recruited and assigned into an observation group,and 100 healthy individuals who took physical examination during the same period served as control group.Based on New York Heart Association(NYHA)heart function classification,the patients in the observation group were divided into Grade Ⅰ(60 cases),Ⅱ(72 cases),Ⅲ(102 cases),and Ⅳ(66 cases)subgroups.Their clinical data were collected,serum GDF-8 and Sir4 levels were detected,left ventricular remodeling was evaluated with echocardiography,and cardiac dysfunction was assessed with NYHA cardiac function grading.Pearson and Spearman correlation analyses were used to analyze the correlation of GDF-8 and Sir4 levels with left ven-tricular remodeling and myocardial injury.Results The observation group had significantly larger left atrial diameter(LAD)and left ventricular end diastolic diameter(LVEDD),thicker left ven-tricular posterior wall thickness(LVPWT)and interventricular septum thickness(IVST),and higher left ventricular mass index(LVMI)and serum Sir4 and GDF-8 levels(42.46±4.75 mm vs 36.39±5.33 mm,54.63±7.96 mm vs 47.42±8.08 mm,9.44±1.21 mm vs 8.49±0.88 mm,9.27±1.58 mm vs 8.66±1.71 mm,141.49±5.32 g/m2 vs 106.52±7.33 g/m2,3.69±1.06 g/L vs 1.48±0.42 g/L,33.75±10.64 g/L vs 19.08±5.13 g/L,P<0.01),but lower LVEF[(40.02±10.14)%vs(63.64±6.13)%,P<0.01]and left ventricular remodeling index(LVRI,1.05±0.24 g/ml vs 1.32±0.33 g/ml,P<0.01)when compared with the control group.The levels of Sir4 and GDF-8,as well as LVMI,were gradually increased,while the LVRI was decreased in Grades Ⅰ,Ⅱ,Ⅲ,and Ⅳ subgroups in turn,with statistical differences in the subgroups(P<0.01).Pearson and Spearman correlation analyses showed that Sir4 and GDF-8 levels were positively correlated with LAD,LVEDD,LVPWT,IVST,LVMI,and NHYA cardiac function grade(P<0.01),and nega-tively with LVEF and LVRI(P<0.01).Conclusion Serum Sir4 and GDF-8 levels are abnormally elevated in elderly CHF patients,and their levels are positively correlated with the severity of left ventricular remodeling and the severity of cardiac dysfunction.
8.Internal fixation with a reduction plate assisted by a self-designed lower extremity fracture traction reduction device for tibial plateau fractures of Schatzker type Ⅵ
Wang LIN ; Weizhong GUO ; Chengshou LIN ; Yingying WANG ; Shenshen ZHANG ; Shenggui XU ; Yu SU ; Weimin LIN
Chinese Journal of Orthopaedic Trauma 2022;24(6):489-495
Objective:To explore the clinical efficacy of internal fixation with a reduction plate assisted by our self-designed lower extremity fracture traction reduction device for tibial plateau fractures of Schatzker type Ⅵ.Methods:A retrospective study was conducted of the 32 patients with tibial plateau fracture of Schatzker type Ⅵ who had been treated at Orthopaedic Department, Mindong Hospital Affiliated to Fujian Medical University from April 2018 to July 2021. Depending on their treatments, they were divided into 2 groups. In the control group of 16 cases subjected to open reduction and internal fixation with manual traction, there were 9 males and 7 females with an age of 50.0±11.7 years; in the observation group of 16 cases subjected to internal fixation with a reduction plate assisted by our self-designed lower extremity fracture traction reduction device, there were 8 males and 8 females with an age of 54.6±11.1 years. The operation time, fracture reduction time, total incision length, intraoperative blood loss, Rasmussen knee function score and maximum active range of knee motion were compared between the 2 groups.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability between the groups ( P>0.05). The operation time [(158.6±26.0) min], fracture reduction time [(61.6±9.6) min], and total incision length [16.0 (13.3, 17.0) cm] in the observation group were significantly shorter than those in the control group [(199.9±60.9) min, (73.8±17.2) min, and 20.0 (17.0, 21.8) cm]; the intraoperative blood loss [175.0 (100.0, 200.0) mL] in the observation group was significantly less than that in the control group [200.0 (162.5, 387.5) mL]; the maximum active ranges of knee motion at one week and one month in the observation group were 94.9°±12.0° and 113.8°±14.1°, significantly larger than those in the control group (78.3°±14.6° and 96.8°±11.4°) (all P<0.05). Fractures achieved bony union at one year after operation in both groups. At 12 months after operation, there was no significant difference in the maximum active range of knee motion or the Rasmussen knee function score between the 2 groups ( P>0.05). Conclusion:In the treatment of Schatzker type Ⅵ tibial plateau fractures, compared with manual traction and open reduction, internal fixation with a reduction plate assisted by our self-designed lower extremity fracture traction reduction device can shorten operation time and total incision length, reduce intraoperative blood loss, and facilitate postoperative functional recovery of the knee for the patients.
9.Monitoring and analysis of hepatitis B virus marker in sera with Uygur pupil in South Xinjiang
Enjie XU ; Maimaiti Yimin · Tuerxiu ; Yeqing XU ; Siyi LI ; Feng WANG ; Shuang ZHANG ; Shenshen WANG ; Shengli BI ; Liping SHEN
Chinese Journal of Experimental and Clinical Virology 2016;(1):84-86
Objective To get the situation with the Uygur students of hepatitis B virus marker in south Xinjiang , provide basis for physical examination system.Methods 398 blood samples of pupils in the southern region of Xinjiang were collected , 5 serological markers of hepatitis were detected with ELISA. Results The HBsAg positive rate was 1.26% ( 5/398 ) of the samples from the pupils in the southern region of Xinjiang, HBsAb positive rate was 50.47% ( 201/398 ) .There was no significance difference between male and female for the HBsAg and HBsAb positive rate (P>0.05).Conclusions The infection rate of HBV is relatively low among pupils in the southern region of Xinjiang, HBsAg positive rate is lower than the national average level, so the prevention of HBV infection should be enhanced there.
10.Application of G arm X-ray machine in minimally invasive treatment of thoracolumbar vertebral osteoporotic vertebral compression fractures
Jun LIU ; Yanxiong LIU ; Shenshen HAO ; Zhibin LIU ; Xiaona JI ; Fei WANG ; Changhong LI ; Fan DU
Clinical Medicine of China 2019;35(2):97-101
Objective To compare the clinical effects of G-arm X-ray machine and C-arm X-ray machine in percutaneous kyphoplasty (PKP) for osteoporotic vertebral compression fracture (OVCF) of thoracolumbar spine.Methods The clinical data of ninety-five patients with thoracolumbar OVCF treated with PKP from May 2016 to August 2017 in Yanan University Affiliated Hospital were retrospectively analyzed.They were divided into two groups according to the different guiding fluoroscopy methods used during the operation.Forty-six cases in G arm group completed PKP under the guidance of G arm X-ray machine,Forty-nine cases in C arm group completed PKP under the guidance of C arm X-ray machine.The operation time,fluoroscopy times,cement leakage cases,the height of injured vertebral leading edge,Cobb angle of kyphosis,visual analogue score and Oswestry dysfunction index were recorded before and after operation,and the related indexes were analyzed and compared.Results Two groups of patients were successfully completed surgery,no complications of vascular and nerve injury.The operation time and fluoroscopy times in G arm group were less than those in C arm group (operation time:(29.6±4.5) min vs.(42.5±5.3) min,and fluoroscopy times in G arm group:(9.1±2.0) vs.(16.9±3.2));the difference was statistically significant (t =-12.747,12.870,P< 0.01).Postoperative height of injured vertebral leading edge(G arm group (22.3±5.3) mm),C arm group (22.4±5.1) mm),kyphosis Cobb angle (G arm group (9.2±3.8)°,C arm group (9.3±3.7) o),visual analogue score (G arm group (2.1±0.7)points,C arm group (2.2±0.9) points),Oswestry dysfunction index (G arm group (21.3±8.5) points,C arm group(21.5 ± 8.3)points),compared with preoperative(the hight of injured vertebral leading edge of G arm group (18.2 ±5.3) mm,C arm group (18.4±5.2) mm,Cobb angle of injured vertebra G arm group (15.7±4.4) °,C arm group (15.9±4.3) °,visual analogue score of G arm group (7.8± 1.2) points,C arm group (7.7± 1.1) points,Oswestry dysfunction index score of G arm group(41.2±8.3)points,C arm group (41.5±8.2) points),the difference was statistically significant (t =-3.709,-3.844,-7.582,-8.144,27.827,27.088,11.360,11.999,P<0.01),but there was no significant difference between the two groups (P >0.05).Conclusion Using G-arm X-ray machine to assist PKP in the treatment of thoracolumbar spine OVCF can effectively shorten the operation time,reduce the intraoperative fluoroscopy time,and the clinical effect is satisfactory.