1.The Effect of Long-term Partial Sleep Deprivation on Learning and Memory in Young Mice
Fan JIANG ; Shenghu WU ; Chonghuai YAN
Chinese Mental Health Journal 2002;0(09):-
Objective:To investigate the effect of long-term partial sleep deprivation on young mice's learning and memory and explore its probable mechanism Methods:We established the long-term sleep deprivation model in young mice first After 30 days sleep deprivation, the spatial learning and memory of the mice were tested by water maze automatic control device Then the immunohistochemical staining was used to examine nNOS expression in prefrontal cortex and hippocampus of right cerebral hemisphere Light microscopy and image analyzer was used to study the samples Results:Long-term sleep deprivation resulted in learning and memory impairment The mice in study group spend longer time for arriving the end than mice of control group, with much more faults in the routine of maze The immunohistochemical staining of nNOS showed that the expression in prefrontal cortex and hippocampus were greatly decreased following partial sleep deprivation The area of positive and strong positive spots in prefrontal cortex of sleep deprivation group was less than that of control group, but in hippocampus only the area of strong positive spots was significantly different between the two groups Conclusions:Long-term partial sleep deprivation impairs young mice's learning and memory, and the decrease in expression of nNOS in prefrontal cortex and hippocampus maybe a mechanism inducing such impairments
2.Simultaneous Determination of 12 Kinds of Organophosphates inWater and Sediment by High Performance LiquidChromatography-Tandem Mass Spectrometry
Meihong CHEN ; Huaizhou XU ; Ninghui SONG ; Shengmin WU ; Jie CHENG ; Jiang LI ; Shenghu ZHANG ; Lili SHI
Chinese Journal of Analytical Chemistry 2017;45(7):987-995
A method was developed for determination of 12 kinds of phosphate compounds in water and sediment by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) coupled with solid phase extraction (SPE) and ultrasonic extraction.The water samples were concentrated by HLB solid-phase extraction (SPE) column and eluted twice with ethyl acetate, ultrasonic solvent extraction for sediment samples and then repeated the operation of water samples after diluted with deionized water.The sample were separated on a ZORBAX Eclipse Plus C18 (150 mm × 2.1 mm, 3.5 μm) column by a gradient elution with 0.2% formic acid aqueous solution and methanol as the mobile phase.Ion mode analysis was monitored by high performance liquid chromatography mass spectrometer (MRM).The target compounds were quantified by external standard method.At the spiked levels (0.05, 0.1 and 0.5 μg/L), the average recoveries of 12 kinds of OPEs in water samples ranged from 66.4% to 115%, except for TMP (28.5%-47.8%) and TEHP (22.4%-73.8%).The relative standard deviation RSD (n=3) was 0.5%-9.09%, and the method quantification (MOQ) was 0.001-0.05 μg/L, However at the spiked levels of 5, 10 and 50 μg/kg, the average recoveries of 12 kinds of OPEs in sediment samples ranged from 65.4% to 120.0%, except for TMP (35.7%-44.9%) and TCEP (31.2%-48.9%).The relative standard deviation RSD (n=3) was 0.01%-9.54%, and the MOQ for sediment was 0.02-2.0 μg/kg dw.Based on the above methods, the detection and analysis of the targets in the water and sediments samples of Taihu Lake were carried out.The results showed that the concentrations of ΣOPEs were 0.1-1.7 μg/L and 8.1-420 μg/(kg dw), respectively.
3.The trends of changes in children's blood lead levels since the introduction of lead free gasoline in Shanghai.
Chonghuai YAN ; Shenghu WU ; Xiaoming SHEN ; Yiwen ZHANG ; Fan JIANG ; Jiemin YIN ; Jiande ZHOU ; Jiamin HE ; Liming AO ; Yu ZHANG ; Renqiu LI
Chinese Journal of Epidemiology 2002;23(3):172-174
OBJECTIVETo describe trends of changes in blood lead levels in children aged 1 - 6 years during the time period before and after introducing lead free gasoline in Shanghai 1997 and 1999.
METHODSBlood lead levels of 1 969 children aged 1 - 6 years were determined by a sampling survey in five districts of Shanghai in August and September, 1997. Blood lead levels of the same population were re-determined by the same method from April to June in 1998 and from August to September in 1999. Filter paper blood lead test was carried out monthly using the filter paper blood lead proficiency testing program of Centers for Disease Control in the United States. The results from blood lead samples were under acceptable ranges during the study.
RESULTSThe geometric means of blood lead levels were 83 microgram/L in 1997, 80 microgram/L in 1998 and 76 microgram/L in 1999, respectively. The prevalence rates of childhood lead poisoning (blood lead level was equal or more than 100 microgram/L) were 37.8% in 1997, 25.7% in 1998 and 24.8% in 1999. The amounts of decrease on average blood lead levels in the five districts between 1997 and 1999 were 10 microgram/L, 11 microgram/L, 6 microgram/L, 4 microgram/L and 2 microgram/L, respectively.
CONCLUSIONLead poisoning is a preventable disease. The average levels of lead in young children in Shanghai decreased significantly after the introduction of lead free gasoline to Shanghai. Lead emissions from vehicles running on leaded gasoline was one of the important contributors to increase the children's blood lead levels in Shanghai. Lead poisoning is not evenly distributed among children in Shanghai, resulting in the different levels of decline.
Child, Preschool ; China ; Environmental Monitoring ; methods ; standards ; Environmental Pollutants ; blood ; Gasoline ; standards ; Humans ; Lead ; blood ; Time Factors
4.Comparison of filling ratio, alignment, and stability between ABG Ⅱ short-stem and Corail long-stem in total hip arthroplasty for Dorr type C femur.
Xianchao BAO ; Mingyang LI ; Limin WU ; Shenghu JIANG ; Bin SHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):641-646
OBJECTIVE:
Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem.
METHODS:
Among patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant ( P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up ( P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software.
RESULTS:
X-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group ( P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group ( P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group ( P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant ( P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group ( P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant ( P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups ( P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group ( P<0.05).
CONCLUSION
Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Femur/surgery*
;
Hip Prosthesis
;
Lower Extremity/surgery*
;
Prosthesis Design
;
Retrospective Studies