1.Efficacy analysis of endovascular stenting for aortic arch artery stenosis after nasopharyngeal carcinoma radiotherapy
Xiaoming YIN ; Jieqing WAN ; Yiling FAN ; Yaohua PAN ; Shenghao DING ; Lei CHEN ; Jiyao JIANG
Chinese Journal of Cerebrovascular Diseases 2014;(4):196-200
Objective To investigate the efficacy of endovascular stenting for aortic arch artery stenosis after nasopharyngeal carcinoma radiotherapy. Methods The clinical data of 8 patients with symptomatic severe aortic arch artery stenosis after nasopharyngeal carcinoma radiotherapy were analyzed retrospectively. The patients were all received endovascular stenting,and their improvement of cerebral ischemic symptoms was observed. They were followed up by cervical color Doppler ultrasound.Results The whole brain vascular DSA confirmed that there were 24 severe arterial stenoses on the aortic arch arteries of extracranial segments in 8 patients,including 11 in internal carotid artery,2 in common carotid artery,10 in vertebral artery and 1 in subclavian artery. The patients were treated with vascular angioplasty and stenting respectively. All the patients were followed up for 1 year;there were no recurrence of cerebral ischemic symptoms.Cervical color Doppler ultrasound did not reveal any obvious restenosis. Conclusion Endovascular stent angioplasty for the treatment of aortic arch artery stenosis after nasopharyngeal carcinoma radiotherapy is relatively safe and feasible.
2.Design and application of a new heat-and-moisture exchanger with anti-splash sputum suctioning function
Zhiyuan FAN ; Liufang XU ; Zhonghua SHAO ; Huijie YU ; Shenghao GUI
Chinese Critical Care Medicine 2022;34(11):1206-1208
In the emergency department, open endotracheal suctioning for mechanically ventilated patients with endotracheal intubation will lead to the spread of respiratory droplets and aerosols, polluting the surrounding environment and medical staff. The traditional heat-and-moisture exchanger has the effect of warming and humidifying, and can block pathogenic microorganisms, but it does not have the function of inserting a sputum suction tube. When the heat-and-moisture exchanger is pulled out for sputum suction, it is easy to cause sputum splash, which pollutes the surrounding environment and medical personnel. The addition of closed sputum suction devices will increase the economic burden on patients. Thus, the medical staff of emergency department of the First People's Hospital of Tongxiang City of Zhejiang Province designed a new type of heat-and-moisture exchanger with anti-splash sputum suctioning function and obtained the National Utility Model Patent of China (ZL 2021 2 0017615.0). The new heat-and-moisture exchanger is mainly composed of a receiving cavity, a connecting tube, a sputum suction tube intubation tube, a sealing valve, etc. The disposable sputum suction tube can be used to insert sputum suction, and at the same time, it can prevent the secretion from splashing to ensure sealing. The patent combines the humidification and pathogen blocking functions of the heat-and-moisture exchanger with the anti-splash sputum suctioning function, which is suitable for use in the emergency and critical care medicine departments and has clinically practical value.
3.Persistent proatlantal artery, a case repor
Shenghao Fan ; Xiaowei Hu ; Hu, Hui Wang ; Xiuying Cai ; Qi Fang
Neurology Asia 2019;24(2):189-191