1.A Method for Extracting Data Elements from Chinese Electronic Medical Records
Journal of Medical Informatics 2024;45(8):78-83
Purpose/Significance A method is proposed for extracting data elements from electronic medical records(EMR)based on national standards,helping to achieve fine-grained sharing of EMR data.Method/Process The ALBERT,BILSTM and CRF models are used to perform sequence labeling on EMR,and a set of candidate data elements based on labeling results are generated.For any can-didate data elements,the contextual information is collected to form an enhanced key vector.Then the similarity between the vector and the standard vector is calculated to determine whether the candidate data element is valid.Result/Conclusion The F1 value is 90.32%,indicating the proposed method has a good performance.
2.THE RELATIONSHIP BETWEEN STRUCTURE AND MECHANICS OF THE VENOUS VALVE
Yueqin QIN ; Sishun ZHOU ; Jinbao WU ; Jingen SHEN ; Xiaoming YANG ; Qiangsu GUO ; Shaoyou CHU ; Jianguo ZHU ;
Acta Anatomica Sinica 1957;0(04):-
The human venous valve of the brachial,femoral and long saphenous veins wereexamined with light,transmission and scanning electron microscopy.The observationshows that the venous valve is composed of three functional layers covered withendothelium on both surfaces.A loosely structured layer is located underlying theendothelium.A network mainly containing randomly oriented elastic fibers was foundnear the side towards the lumen.To the side towards the venous wall,there is adense layer composed of eircumferentially and transversly oriented collagen bundles.Some smooth muscle cells extend from the wall of the vein to the base of thevenous valve.The elastic fibers and smooth muscle cells together with the collagenfibers contribute to the mechanical load-bearing performance of the valve and to thepassive closing and openning mechanism.In addition,the smooth muscle cells mightplay an active role in the normal functioning of the valve.The scanning and transmission electron microscopy of venous valve showdifferent arrangement of the endothelium.On the surface of the valve next to the wallof the vein,the endothelial cells are transversely arranged,while on the othersurface over which the current of blood flows,the cells are longitudinally arrangedin the direction of the current.These accord with the role of fluid mechanics.12 normal venous valves were tested by universal testing instrument (Instrontype 1122).The mean value of the maximum tension of the valve is 1 N.Theaverage value of the tensile ultimate strength is 10N/mm~2.