1.Research about using comfortable nurisng for patients with malignant tumor to promote their qual-ity of life
Shanhong ZHENG ; Chunyan LIU ; Aihua ZHANG
Chinese Journal of Practical Nursing 2009;25(29):1-3
Objective To know the influence of comfortable nursing for paitnets with malignant tumor on promoting their quality of life. Methods Selected 995 patients with malignant tumor who had diagnosed by pathology and coured by chemotherapy or radioehemotherapy. Divided them into the experimental group (498 cases) and the control group (497 cases) randomly. Routine nursing cares were used in the control group,while the comfortable nursing cares were used in the experimental group in addition. QLQ-C30 was used to evaluate the level of patients'quality of life at the time of beginning, ending and the midpoint of the treatment. Results There was no significant difference between the two groups about the QLQ-C30 values at the beginning of the treatment, while the differences were signifi-cant at the other two time points, the level of quality of life in the experimental group was better than in the control group. Conclusions Comfortable nursing can promote quality of life of patients with malignant tumor, which should be developed in the clinical field.
2.Comparison on the antineoplastic immunological effects of nanoemulsion vaccine given throngh different routes
Wei GE ; Yuan LI ; Shanhong ZHANG
Medical Journal of Chinese People's Liberation Army 1983;0(02):-
Objective To compare the antineoplastic immunological effects of nanoemulsion-encapsulated MAGE1-HSP70 and SEA(the ratio of MAGE1-HSP70 fusion protein to SEA superantigen was 100∶1)as NE(MHS)vaccine as given in different routes,and try to look for a novel and effective immune route.Methods NE(MHS)was prepared using magnetic ultrasound methods,and the size,the encapsulation rate and the stability of the nanoemulsion vaccine were evaluated.C57BL/6 mice were immunized via p.o.,subcut.,i.v.,or i.p.route.The cellular immunocompetence was detected by ELISpot assay and LDH release assay.The therapeutic and tumor challenge assay were examined too.Results When the vaccine was given orally,the tumor masses formed 28 days after B16-MAGE1 inoculation in mice were markedly bigger than that formed in the mice of the other groups(P
3.Comparison of diagnostic performances between bedside sonography and chest x-ray in severe pneumonia
Shanhong ZHANG ; Hongbo ZHANG ; Xiaolei LIU ; Guoqiang ZHANG
Chinese Journal of Emergency Medicine 2014;23(12):1366-1370
Objective To evaluate the diagnostic performances of bedside lung ultrasound (US) and chest radiography (CXR) in patients with severe pneumonia.Method Lung ultrasound (US),CXR and chest CT were performed in sequence in adult patients admitted to the emergency department for suspected acute respiratory failure caused by severe pneumonia.Here,chest CT served as a golded standard for comparison.The diagnostic efficacy of US for the detection of severe pneumonia,defined as rapidity and accuracy (sensitivity,specificity,positive predictive value,negative predictive value) were compared with CXR.Results The number of patients with consolidation of lung,pleural alteration,subpleural pathological changes,and pleural effusion in the severe pneumonia group was higher than that in the nonpneumonia group.Sensitivity of bedside ultrasound examination for the diagnosis of severe pneumonia was 95.7%,and specificity 96.3%,positive predictive value 95.7%,negative predictive value 96.3%,and accuracy 96.0%.There were differences in sensitivity,negative predictive value and accuracy found between CXR and US.Conclusions Bedside chest ultrasound is a reliable device for the diagnosis of severe pneumonia,and superior to CXR in this setting,allowing a more prompt diagnosis and treatment.
4.Micro Potentiometric Label-free Immunosensor for Glycated Hemoglobin
Chao BIAN ; Qiannan XUE ; Jizhou SUN ; Hong ZHANG ; Shanhong XIA
Chinese Journal of Analytical Chemistry 2010;38(3):332-336
A miniaturized potentiometric label-free immunosensor based on the standard complementary metal-oxide-semiconduction transistor(CMOS) process and micro fabrication technique was developed to monitoring diabetes, which could detect the concentrations of glycated hemoglobin (HbA1c) and hemoglobin. This immunosensor includes a micro field-effect transistor based sensor chip integrated with signal readout circuit and a disposable probe electrode. The micro sensor chip was designed by our lab and fabricated by Chartered Semiconductor, Singapore. The disposable probe electrode, which was integrated with sensitive electrodes array and micro reaction pool, was deposited on polyester plastic based on micro fabrication techniques. Antibody of HbA1c and hemoglobin were immobilized on the electrode based on self assemble monolayer and gold nanoparticles. The characteristics of the electrode during modification were studied by cyclic voltammetry and electrochemical impedance technique. The response characteristic of the immunosensor was detected. HbA1c from 4 to 24 mg/L and hemoglobin from 60 to 180 mg/L can be detected by this immunosensor.
5.Effects of HLA-derived peptide on proliferation and heme oxygenase-1 activity of rat spleen cells
Shanhong YI ; Bo SONG ; Zehou WANG ; Genfu ZHANG ; Zhigang CUI ;
Journal of Third Military Medical University 1983;0(04):-
Objective To investigate the immunosuppression function of a novel HLA derived peptide, RDP1258, and its mechanisms. Methods A peptide derived from HLA, RDP1258, was chemically synthesized by artificial solid phase synthesis. Effects of the peptide on alloreactive cytotoxic activity of rat spleen cells and heme oxygenase 1 (HO 1) activity were observed using 3H TdR method and enzyme chemistry method, respectively. Results The synthetic HLA derived peptide could obviously inhibit the proliferation of rat spleen cells and mixed lymphocyte reaction, and reduce HO activity in a dose dependent manner in vitro . Conclusion RDP1258 can significantly inhibit the proliferation of rat spleen cells induced by mitogen and isoantigen possibly by means of affecting HO 1 activity.
6.Clinical value of serum procalcitonin in diagnosis of sepsis caused by gram negative bacterial infection
Shengtao YAN ; Hongbing JIA ; Jianping YANG ; Wen GAO ; Jing SUN ; Shanhong ZHANG ; Chengdong GU ; Guoqiang ZHANG
Chinese Journal of Emergency Medicine 2017;26(3):291-296
Objective To investigate the correlation between serum procalcitonin (PCT) levels and infection sites,as well as between PCT and bacterial species in gram negative (G-) bacteria induced sepsis,so as to provide rationale for therapeutic strategy of using antibiotic in sepsis.Methods The data of patients with sepsis admitted in Emergency Department and ICU from January 2014 to June 2015 were retrospectively analyzed.The blood culture of G-bacteria and PCT detection were carried out simultaneously within 24 hours after admission.The clinical data was analyzed to find out the correlation between PCT levels and infection sites,as well as between PCT levels and pathogenic bacterial species.Results A total of 187 specimens (came from 162 patients) were enrolled in the study with a median age of 70 years old and a median sequential organ failure assessment (SOFA) score of 4.PCT levels were found to be associated with bacterial species.PCT level caused by Escherichia coli bacteremia infection was higher than that caused by Acinetobacter baumannii bacteremia and Burkholderia cepacia bacteremia infection (4.62 ng/mL vs.2.44 ng/mL;4.62 ng/mL vs.0.81 ng/mL;P < 0.05).Receiver operating characteristic (ROC) analysis showed an area under the curve (AUC) for PCT was 0.61 to discriminate Escherichia coli infection from Acinetobacter baumannii infection and an AUC was 0.66 to discriminate Escherichia coli infection from Burkholderia cepacia infection.When the cutoff point of PCT was 30.32 ng/mL,it could predict Escherichia coli infection rather than Acinetobacter baumannii infection with 94.10% specificity,90.00% positive predictive value and positive likelihood ratio for 4.24.When the cutoff point of PCT was 8.01 ng/mL,it could predict Escherichia coli infection rather than Burkholderia cepacia infection with 85.70% specificity,93.94% positive predictive value,and positive likelihood ratio for 3.01.When PCT cutoff value reached 47.31 ng/mL,the specificity and positive predictive value were both 100.00%.PCT level caused by urinary tract infection was higher than that caused by pulmonary infection (11.58 ng/mL vs.2.07 ng/mL,P < 0.05),and the AUC was 0.69.When the cutoff point of PCT was 32.11 ng/mL,it could predict Escherichia coli infection rather than Acinetobacter baumannii infection with 90.60% specificity,86.18% negative predictive value and positive likelihood ratio for 3.68.Conclusions PCT elevation in G-bacteria induced sepsis might be associated with infection sites and bacterial species.
7.Study on the teaching of modular transurethral enucleation of the prostate operation
Xiangwei WANG ; Yuanning ZHANG ; Zhenqiang FANG ; Weisheng JIA ; Shanhong YI ; Gang YE
Chinese Journal of Medical Education Research 2012;11(2):203-205
To establish a new kind of minimally invasive surgical model of transurethral prostate enucleation operation and method that makes the operation easier and reduces the surgeon learning curve.According to the order and the path of surgical operation,prostate enucleation operation is split into 4 different modules named as A,B,C,D,and it is called modular transurethral enucleation of the prostate.The operation mode optimizes the process of operation design, modularizes the contents of surgical procedures,processes,and reduces the difficulty of the operation,and simplifies the surgical procedure,which can effectively shorten the operation time and make it easy for beginners to carry out and control the procedure.It has a great popularization value.
8.A Micro Electrochemical Sensor for Nitrate Determination Based on Square_wave Pulsating Current Deposition Process
Yang LI ; Jizhou SUN ; Jinfeng WANG ; Chao BIAN ; Jianhua TONG ; Hanpeng DONG ; Hong ZHANG ; Shanhong XIA
Chinese Journal of Analytical Chemistry 2015;(1):98-104
Based on microfabrication technology and electrochemical modification method, a micro electrochemical sensor for nitrate ( NO-3 ) determination was developed. A micro sensor chip with working electrode and counter electrode was used as the signal convertor of the sensor. The area of the micro working_electrode was only 1 mm2 . As an electrocatalysis sensitive material, copper was electrodeposited onto the working electrode by square_wave pulse current electrodeposition method. The morphologies and components of freshly deposited materials were examined by scanning electron microscopy ( SEM ) and X_ray diffraction ( XRD) to explore key factors that affected the electrocatalytic ability of the deposited copper layer for reducing nitrate ions. The experimental results revealed that under the optimal conditions, the deposited copper layer was macroporous and had a larger effective surface area that could serve as a more effective electrocatalyst in facilitating nitrate reduction. Electrochemical response of the macroporous copper layer was characterized by linear sweep voltammetry in acidic supporting electrolytes ( pH=2 ) . The electroanalytical results showed that the modified microsensor had marked sensitivity for standard nitrate samples within the concentration range from 12. 5 to 3000 μmol/L (in the range of 12. 5-200 μmol/L yielded straight line:y1=-0. 1422x-10. 326, R12=0. 9976, while in the range of 200-3000 μmol/L yielded straight line: y2=-0. 0984x-22. 144, R22=0. 9927) with a detection limit of 2 μmol/L (S/N=3). The developed electrochemical microsensor was also employed for nitrate determination in water samples collected from lakes and rivers near the city of Beijing. The results were in good agreement with the data given by qualified water quality detection institute, with the deviations from 3 . 9% to 15 . 4%.
9.The modulation mechanism of LiCl inhibited the Pseudomonas aeruginosa-induced inflammation
Qiang FU ; Kang CHEN ; Fuda HUANG ; Lishao MIAO ; Shanhong YANG ; Xiuming ZHANG
International Journal of Laboratory Medicine 2017;38(1):13-15
Objective To explore the role of LiCl in modulating bacterial-mediated inflammation after Pseudomonas aeruginosa infection.Methods Western-blot was used to determine the efficacy of LiCl usage.The expression of inflammatory cytokines in Pseudomonas aeruginosa-infected macrophages and neutrophils was detected by qPCR.Cell apoptosis was measured by flow cytometry.Results Western-blot data showed that LiCl up-regulated the protein levels of p-GSK-3β(Ser 9)and β-catenin in macrophages and neutrophils,indicating the efficacy of LiCl usage.qPCR data indicated that LiCl enhanced the expression of anti-inflammatory cytokines and suppressed the expression of pro-inflammatory cytokines in Pseudomonas aeruginosa-infected macrophages and neutrophils.Flow cytometry data indicated that LiCl could promoted the apoptosis of Pseudomonas aeruginosa-infected macrophages and neutrophils.Conclusion LiCl inhibited the Pseudomonas aeruginosa-induced inflammation,via regulating the inflammatory cytokine expression and the apoptosis of inflammatory cells.
10.In vitro activity of antimicrobial agents against Enterococcus spp
Wei GE ; Xiaoxiao ZHANG ; Dingcheng WANG ; Hailian SHAO ; Ying LI ; Ming YANG ; Zhi CHENG ; Bo SU ; Mingle FAN ; Shanhong FAN
Chinese Journal of Infection Control 2015;(11):753-756
Objective To investigate in vitro activity of antimicrobial agents against Enterococcus spp . isolated from clinic specimens in a hospital.Methods 188 Enterococcus spp . isolates from specimens sent by clinic depart-ments in June 2013-July 2014 were identified and performed antimicrobial susceptibility testing.Results Of 188 En-terococcus spp . isolates,119 were Enterococcus faecium (E.faecium),60 were E.faecalis ,and 9 were E.avium, these strains were mainly isolated from urine (34.57%)and blood specimens (19.15% ).No daptomycin and linezolid-resistant strain was detected;resistant rates of E.faecium to vancomycin was 1 .68%,to penicillin, ampicillin,high concentration gentamycin,erythromycin,and levofloxacin were all > 70%;except tetracycline, resistant rates of E.faecalis to the other antimicrobial agents were all lower than E.faecium,resistant rates of E. faecalis to penicillin and ampicillin were 16.67% and 13.33% respectively.Conclusion Daptomycin has high activity against Enterococcus spp . in this hospital.