1.Democidiosis in Rosacea Type.
Wook Hwa PARK ; Seung Ki PARK ; Tae Ha WOO
Korean Journal of Dermatology 1970;8(1):85-87
The authors present seven cases of Democidiosis in rosacea type and the subject of human demodetic infestation has been reviewed. According to our experience, demodex folliculorum, although a normal inhabitant of the sebaceous glands in small numbers, when encouraged to multiply by the patients excessive use of facial cream and avoidance of soap, can produce democidiosis. The diagnosis was easily confirmed by characteristic clinical appearance and simple microscopy. The characteristie clinical appearances are indurated non-comedous papules and pustules with unique cherry pinkish red erythema. The response to treatment, consisting of daily soap and water cleansing of the face, followed by the local application of a suitable antiparasitic remedies is simple and gratifying. But the erythema was not respond to antiparasitic preparation.
Diagnosis
;
Erythema
;
Humans
;
Microscopy
;
Prunus
;
Rosacea*
;
Sebaceous Glands
;
Soaps
;
Water
2.Prominent Large V Wave in Mitral Stenosis and It's Clinical Significance.
Sang Wook KIM ; Jae Kwan SONG ; Seung Ho KANG ; Duk Hyun KANG ; Seong Wook PARK ; Jae Joong KIM ; Jong Hun PARK ; Seung Jung PARK
Korean Circulation Journal 2000;30(2):147-152
BACKGROUND AND OBJECTIVES: Although a prominent large V wave in left atrial pressure tracing (PVLAP) has been reported to be associated with significant mitral regurgitation (MR) or decreased left atrial compliance (LAC), it is sometimes observed in patients with tight mitral stenosis (MS). The purpose of this study was to determine the prevalence and the hemodynamic significance of PVLAP in tight MS. MATERIALS AND METHODS: Catheterization data before percutaneous mitral balloon valvuloplasty (PMV) were analyzed in 84 consecutive patients and PVLAP was defined as V wave 10 mm Hg higher than mean left atrial pressure (MLAP). RESULTS: PVLAP was observed in 45% (38/84) and factors associated with PVLAP were younger age (p=0.02), higher MLAP (p<0.01), higher mitral gradient (p=0.04), smaller valve area (p=0.01) and low echo score (p=0.02): among them MLAP was the only independent factor in multivariate analysis. The presence of PVLAP had no effect on the result of PMV and successful PMV abolished PVLAP. CONCLUSION: PVLAP was observed not infrequently in these selected patients with MS referred for PMV. The presence of PVLAP was not associated with MR and had good correlation with MLAP, which suggest that PVLAP be determined by decreased LAC.
Atrial Pressure
;
Balloon Valvuloplasty
;
Catheterization
;
Catheters
;
Compliance
;
Hemodynamics
;
Humans
;
Mitral Valve Insufficiency
;
Mitral Valve Stenosis*
;
Multivariate Analysis
;
Prevalence
3.Coronary Artery Stenting(Palmaz-Schatz) ; Immediate Results.
Seung Jung PARK ; Seong Wook PARK ; Jae Joong KIM ; Jae Kwan SONG ; Simon Jong LEE
Korean Circulation Journal 1991;21(5):809-820
Since after first report of percutaneous transluminal coronary angioplasty in 1977, improved operator technique and advanced equipment designs have resulted in an increase in primary success rate from 67% to 92% in recent days. Despite these improvement, acute closure and restenosis remain as serious limitations to both the short and long-term success of PTCA. Coronary artery stents have been proposed as a method of treating acute closure and preventing restenosis. We implanted 21 balloon expandable Palmaz-Schatz Stent in selected 21 Patients(mean age 62+/-8 years, M/F : 16/5) with atherosclerotic coronary artery disease. The indications were elective stenting in 17, acute dissection postangioplasty in 2 and restenosis following angioplasty in 2. The clinical diagnosis of the subjects was unstable angina in 12 pts(57%), stable angina in 1, and post infarction angina in 8 including 6 acute myocardial infarction. The target vessel was right coronary artery In 12(57%), left anterior descending artery in 6(29%) and left circumflex in 3(14%). The size of implanted stent was 3mm in 15, 3.5mm in 5 and 4.0mm in 1. The morphology of attempted lesion was AHA/ACC classification type A in 1, type B in 17(B1 ; 1, B2 ; 16) and type C in 3. Angiographic findings were 1-vessel disease in 16 patients, 2-vessel disease in 4 and 3-vessel disease in 1. Coronary artery stenting wast technically successful in 21 all patients(100%) and complications included subacute total occlusion 1 week after stenting in 1, which was recanalized successfully by repeat PTCA without myocardial infarction, prolonged sinus arrest after stenting due to microembolism in 1 and puncture site bleeding requiring transfusion in 1. CONCLUSION: Coronary artery stenting was a safe and effective procedure to obtain adequate coronary blood flow in selected patients but long-term efficacy of primary elective coronary stenting should be evaluated prospectively.
Angina, Stable
;
Angina, Unstable
;
Angioplasty
;
Angioplasty, Balloon, Coronary
;
Arteries
;
Classification
;
Coronary Artery Disease
;
Coronary Vessels*
;
Diagnosis
;
Equipment Design
;
Hemorrhage
;
Humans
;
Infarction
;
Myocardial Infarction
;
Punctures
;
Stents
4.Coronary Artery Stenting(Palmaz-Schatz) ; Immediate Results.
Seung Jung PARK ; Seong Wook PARK ; Jae Joong KIM ; Jae Kwan SONG ; Simon Jong LEE
Korean Circulation Journal 1991;21(5):809-820
Since after first report of percutaneous transluminal coronary angioplasty in 1977, improved operator technique and advanced equipment designs have resulted in an increase in primary success rate from 67% to 92% in recent days. Despite these improvement, acute closure and restenosis remain as serious limitations to both the short and long-term success of PTCA. Coronary artery stents have been proposed as a method of treating acute closure and preventing restenosis. We implanted 21 balloon expandable Palmaz-Schatz Stent in selected 21 Patients(mean age 62+/-8 years, M/F : 16/5) with atherosclerotic coronary artery disease. The indications were elective stenting in 17, acute dissection postangioplasty in 2 and restenosis following angioplasty in 2. The clinical diagnosis of the subjects was unstable angina in 12 pts(57%), stable angina in 1, and post infarction angina in 8 including 6 acute myocardial infarction. The target vessel was right coronary artery In 12(57%), left anterior descending artery in 6(29%) and left circumflex in 3(14%). The size of implanted stent was 3mm in 15, 3.5mm in 5 and 4.0mm in 1. The morphology of attempted lesion was AHA/ACC classification type A in 1, type B in 17(B1 ; 1, B2 ; 16) and type C in 3. Angiographic findings were 1-vessel disease in 16 patients, 2-vessel disease in 4 and 3-vessel disease in 1. Coronary artery stenting wast technically successful in 21 all patients(100%) and complications included subacute total occlusion 1 week after stenting in 1, which was recanalized successfully by repeat PTCA without myocardial infarction, prolonged sinus arrest after stenting due to microembolism in 1 and puncture site bleeding requiring transfusion in 1. CONCLUSION: Coronary artery stenting was a safe and effective procedure to obtain adequate coronary blood flow in selected patients but long-term efficacy of primary elective coronary stenting should be evaluated prospectively.
Angina, Stable
;
Angina, Unstable
;
Angioplasty
;
Angioplasty, Balloon, Coronary
;
Arteries
;
Classification
;
Coronary Artery Disease
;
Coronary Vessels*
;
Diagnosis
;
Equipment Design
;
Hemorrhage
;
Humans
;
Infarction
;
Myocardial Infarction
;
Punctures
;
Stents
5.Percutaneous Transluminal Angioplasty with Palmaz-Schatz Stent in the Carotid Artery Stenosis.
Sang Sig CHEONG ; Seong Wook PARK ; Seung Jung PARK ; Dae Chul SUH ; Myoung Chong LEE
Korean Circulation Journal 1996;26(4):921-925
Carotid endarterectomy is superior to medical treatment in preventing secondary stroke in patients with symptomatic high grade carotid stenosis. Transluminal angioplasty is a promising procedure as an alternative treatment for these patients. We report two cases of carotid angioplasty with Palmaz-Schatz stent in patients with carotid artery occlusive disease. One patient presented with decreased right visual acuity because of retinal arterial embolism. The angiogram demonstrated a discrete tight stenosis of right internal carotid artery carotid stenting with Palmaz-Schatz coronary stent was performed without any significant complications. The other patient presented with recurrent episodes of cerebral infarction, for which he had undergone left carotid erdarterectomy 3-years ago. The carotid angiogram demonstrated tight stenoses of both internal carotid arteries. Carotid artery stenting was performed at left and right internal carotid arteries without any complications. We suggest that stenting may be an effective and safe therapeutic alternative to surgical treatment in some selected patients with carotid artery occlusive disease.
Angioplasty*
;
Carotid Arteries*
;
Carotid Artery, Internal
;
Carotid Stenosis*
;
Cerebral Infarction
;
Constriction, Pathologic
;
Embolism
;
Endarterectomy, Carotid
;
Humans
;
Retinaldehyde
;
Stents*
;
Stroke
;
Visual Acuity
6.Inhibitory effects of several drugs to intestinal secretory stimulation of heat-labile enterotoxin produced by enterotoxigenic E. coli.
Kyung Rae MOON ; Sang Kee PARK ; Young Wook CHUN ; Kap Seung KIM ; Young Bong PARK
Journal of the Korean Pediatric Society 1991;34(9):1231-1239
No abstract available.
Enterotoxigenic Escherichia coli*
;
Enterotoxins*
7.Manidipine Monotherapy in Patients with Mild to Moderate Essential Hypertension.
Jong Koo LEE ; Seong Wook PARK ; Jae Kwan SONG ; Jae Joong KIM ; Seung Jung PARK
Korean Circulation Journal 1992;22(2):301-306
A clinical trial was done to evaluate the antihypertensive efficacy and side effects of manidipine, a new calcium antagonist, in 30 patients with mild to moderate essential hypertension. 1) The study patients consisted of 19 men and 11 women, and the mean age was 51.8 years. 2) Blood pressure dropped significantly in 2 weeks and in 4 weeks, and well maintained throughout the study period. The mean-pressure drop was 26.2/14.9mmHg after 10 weeks. 3) Heart rate did not change significantly with manidipine therpy. 4) Optimal dose for effective pressure-drop was between 10 and 20 mg in 86% of patients. Overall good antihypertensive effect was achieved in 83% of patients. 5) All of the laboratory parameters including blood chemistry, glucose, lipid and electrolytes did not change, but serum calcium increased from 9.2% mg/dl (p=0.001) in 10 weeks. 6) Side effects were mild in nature(palpitation in 3, dry mouth in 1, weakness in 1 and impotence in 1 patient). In conclusion, manidipine monotherapy with 10 to 20 mg once a day regimen is effective and well tolerated in the patients with mild to moderate essential hypertension.
Blood Pressure
;
Calcium
;
Chemistry
;
Electrolytes
;
Erectile Dysfunction
;
Female
;
Glucose
;
Heart Rate
;
Humans
;
Hypertension*
;
Male
;
Mouth
8.Endothelium-dependent and Independent Responsiveness to Endothelin in Porcine Coronary Artery.
Myeong Ki HONG ; Jae Joong KIM ; Cheol Whan LEE ; Seong Wook PARK ; Seung Jung PARK
Korean Circulation Journal 1998;28(12):1993-2001
BACKGROUND: The purpose of this study was to investigate the mechanism of endothelium-dependent and independent responses to endothelins (ETs) in porcine coronary artery. METHODS: The vascular rings of left anterior descending artery or left circumflex artery from 7 pigs were suspended in conventional organ chambers for the measurement of isometric force. To evaluate relaxation responses, vascular rings with endothelium were exposed to ET-1 and ET-3. To evaluate contraction responses, vascular rings with and without endothelium were exposed to ET-1 and ET-3 in the presence or absence of BQ 123 (ET(A) receptor antagonist) or TAK-044 (ET(A) and ET(B) receptor antagonist). RESULTS: Transient relaxation responses of vascular rings occurred after exposure of ET-1 and ET-3. These transient responses disappeared after preincubation with N-nitro-L arginine. There was an increased contractions of vascular rings according to increasing concentration of ET-1 and ET-3. The initial responses were enhanced in vascular rings without endothelium in ET-1 and ET-3. In vascular rings with endothelium, the contraction responses were more reduced in vascular rings with preincubation of BQ 123 than in vascular rings without BQ 123 in ET-1. In vascular rings without endothelium, the contraction responses were more reduced in vascular rings with preincubation of TAK-044 than in vascular rings without TAK-044 in ET-1. CONCLUSION: ET(B) receptor on the endothelium might mediate the transient vasodilator responses to ET-1 and ET-3 through release of nitric oxide in porcine coronary artery. ET(A) and ET(B) receptor on vascular smooth muscle cells might mediate vasoconstrictor responses to ETs.
Arginine
;
Arteries
;
Coronary Vessels*
;
Endothelins*
;
Endothelium
;
Muscle, Smooth, Vascular
;
Nitric Oxide
;
Receptors, Endothelin
;
Relaxation
;
Swine
9.Comparison of Results of Percutaneous Mitral Balloon Valvotomy Using Single(Inoue) and Double Balloon Techniques(Randomized Trial) ; Mechanism of Dilation, Immediate Results and Follow Up.
Seung Jung PARK ; Jae Joong KIM ; Seong Wook PARK ; In Whan SEONG ; Simon Jong LEE
Korean Circulation Journal 1990;20(4):659-667
To assess the efficacy of 2 different mitral balloon valvotomy (PMV) techniques, PMV was performed using Inoue balloon (I) in 35 pts and double balloon (D) in 33 pts with mitral stenosis (male 27, female 41, mean age 42+/-12 years). The success rate of PMV was 89%(31/35 pts) in I group and 97%(33/33 pts) in D group. Mitral valve area after dilation increased equally effectively in both groups (I and D) from 0.9+/-0.2 and 0.8+/-0.2 to 1.9+/-0.2 and 1.9+/-0.3cm2 respectively (p<0.0001). There were no differences in degree of improvement of cardiac output, mitral gradient, left atrial pressure, pulmonary artery pressure and various doppler echocardiographic findings in both groups, but EF slope was more improved from 13+/-7 to 48+/-16 mm/sec in D group than those (from 15+/-6 to 39+/-15mm/sec) of I group. Increments of long and short diameters of mitral valve orifice by 2D-echocardiogram were 1.1+/-0.6 and 0.3+/-0.3cm in D group and 0.9+/-0.5, 0.4+/-0.3cm in I group. The ratio of long and short diameter increase was significantly larger in D than that of I group (long/short 2.8+/-0.7 vs 2.4+/-0.7, p<0.05) and short diameter of orifice after dilation was more improved in I than that of D group (1.1+/-0.2 vs 1.0+/-0.2cm p<0.05). Complications included deflation failure of Inoue balloon in 2, and cerebral embolic episode in 1 (D). Incidence of increased mitral regurgitation was 50% in D and 45% in I, development of ASD (Qp/Qs>1.2) was 20% in D, 13% in I group respectively and mean amount of left to right shunt (Qp/Qs) was 1.7+/-0.3 in D and 1.5+/-0.1 in I group. Total procedure and fluoroscopic time were 84+/-24 and 25+/-11 min. in D and 56+/-20 and 16+/-6 min. In I, which had statistically significant differences (p<0.002). Thus we concluded PMV using Inoue or double balloons was equally effective in selected patients. Total procedure and fluoroscopic time of Inoue balloon technique were significantly shorter than those of double balloons. Double balloon technique had more tendency of longitudinal splitting of the commissures.
Atrial Pressure
;
Balloon Valvuloplasty*
;
Cardiac Output
;
Echocardiography
;
Female
;
Follow-Up Studies*
;
Humans
;
Incidence
;
Mitral Valve
;
Mitral Valve Insufficiency
;
Mitral Valve Stenosis
;
Pulmonary Artery
10.Cordis Coronary Stenting without Anticoagulation: Multicenter Results in Korea.
Seong Wook PARK ; Seung Jung PARK ; Myeong Ki HONG ; Jae Joong KIM
Korean Circulation Journal 1997;27(2):164-170
BACKGROUND: Systemic anticoagulation therapy has been recommended to prevent subacute thrombosis after intracoronary stening. Recent data, however, suggest that antiplatelet therapy might be an effective alternative to anticoagulation therapy. We evaluated the effect of antithrombotic regimens on subacute thrombosis and short-term clinical course after successful implantation of Cordis coronary stent, which is a flexible, balloon expandable, radiopaque tantalum stent. METHOD: Two hundred and seventy-five consecutive patients with 290 lesions were treated with 356 Cordis stents implantation. According to post-stent antithrombotic regimen, patients were divided into three groups ; 165 patients with 175 lesions received aspirin 200mg/day, ticlopidine 500mg/day and warfarin for one month(Group 1), 66 patients with 69 lesions received aspirin and ticlopidine(Group 2) and 44 patients with 46 lesions received aspirin alone(Group 3) after successful Cordis stenting. RESULTS: The overall procidural success rates were 97.7% in group 1, 98.6% in group 2 and 100% in group 3. More than 65 percents of the patients were eligible for elective stenting aspirin, ticlopidine and warfarin, 0% in patients with aspirin and ticlopidine, and 6.8% in patients assigned to the treatment with aspirin alone. CONCLUSION: The Cordis coronary stent is an effective endovascular stent in various clinical indications including unstable angina and acute myocardial infarction. Antiplatelet therapy using aspirin and ticlopidine after successful Cordis coronary stenting is promising alternative to anticoagulation therapy to overcome the drawbacks of stenting. However, post-stent antithrombotic therapy with aspirin alone is associated with significant rate of stent thrombosis.
Angina, Unstable
;
Aspirin
;
Coronary Artery Disease
;
Humans
;
Korea*
;
Myocardial Infarction
;
Stents*
;
Tantalum
;
Thrombosis
;
Ticlopidine
;
Warfarin