1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Polycyclic Aromatic Hydrocarbons Mediate the Association between Tobacco Smoking and Alcohol Use Disorder
Dongkyu LEE ; Mun-Joo BAE ; Mi-Ji KIM ; Sung Soo OH ; Ki Soo PARK ; Chan Joo LEE ; Sungha PARK ; Seung-Koo LEE ; Sang-Baek KOH ; Sun Jae JUNG ; Changsoo KIM ; Jaelim CHO
Yonsei Medical Journal 2024;65(12):752-760
Purpose:
Smoking is causally related to alcohol use disorder. Although polycyclic aromatic hydrocarbons (PAHs) are major neurotoxic pollutants in tobacco smoke, evidence is lacking on the role of PAHs in the relationship between smoking and alcohol use disorder. This study investigated the types of PAHs associated with smoking and whether exposure to those PAHs mediated the effect of smoking on alcohol use disorder.
Materials and Methods:
A total of 968 male firefighters were analyzed. Smoking history and cumulative pack-years were obtained using self-reported questionnaires. Alcohol use disorder was defined using the Alcohol Use Disorder Identification Test.PAH exposure was assessed by urinary metabolites. Regression analyses were performed between exposure (smoking), outcome (alcohol use disorder), and mediator (PAH metabolites) variables. A mediation analysis was performed to test the indirect effect of PAH metabolites on the association between smoking and alcohol use disorder. All analyses were repeated for 770 participants who were followed up after 2 years, while alcohol use disorder was redefined from follow-up data ensuring the temporal sequence of the variables.
Results:
Both 2-naphthol [β=0.78, 95% confidence interval (CI): 0.59–0.98] and 2-hydroxyfluorene (β=0.69, 95% CI: 0.56–0.82) were associated with smoking history. Furthermore, 2-naphthol and 2-hydroxyfluorene mediated the associations of smoking history (proportion mediated: 14.2%, 23.6% respectively) or cumulative pack-years (proportion mediated: 14.4%, 25.4% respectively) with alcohol use disorder. The results were consistent in longitudinal settings.
Conclusion
Exposure to PAHs mediated the association between tobacco smoking and alcohol use disorder. PAH exposure from tobacco may increase the risk of addictive disorders.
6.Polycyclic Aromatic Hydrocarbons Mediate the Association between Tobacco Smoking and Alcohol Use Disorder
Dongkyu LEE ; Mun-Joo BAE ; Mi-Ji KIM ; Sung Soo OH ; Ki Soo PARK ; Chan Joo LEE ; Sungha PARK ; Seung-Koo LEE ; Sang-Baek KOH ; Sun Jae JUNG ; Changsoo KIM ; Jaelim CHO
Yonsei Medical Journal 2024;65(12):752-760
Purpose:
Smoking is causally related to alcohol use disorder. Although polycyclic aromatic hydrocarbons (PAHs) are major neurotoxic pollutants in tobacco smoke, evidence is lacking on the role of PAHs in the relationship between smoking and alcohol use disorder. This study investigated the types of PAHs associated with smoking and whether exposure to those PAHs mediated the effect of smoking on alcohol use disorder.
Materials and Methods:
A total of 968 male firefighters were analyzed. Smoking history and cumulative pack-years were obtained using self-reported questionnaires. Alcohol use disorder was defined using the Alcohol Use Disorder Identification Test.PAH exposure was assessed by urinary metabolites. Regression analyses were performed between exposure (smoking), outcome (alcohol use disorder), and mediator (PAH metabolites) variables. A mediation analysis was performed to test the indirect effect of PAH metabolites on the association between smoking and alcohol use disorder. All analyses were repeated for 770 participants who were followed up after 2 years, while alcohol use disorder was redefined from follow-up data ensuring the temporal sequence of the variables.
Results:
Both 2-naphthol [β=0.78, 95% confidence interval (CI): 0.59–0.98] and 2-hydroxyfluorene (β=0.69, 95% CI: 0.56–0.82) were associated with smoking history. Furthermore, 2-naphthol and 2-hydroxyfluorene mediated the associations of smoking history (proportion mediated: 14.2%, 23.6% respectively) or cumulative pack-years (proportion mediated: 14.4%, 25.4% respectively) with alcohol use disorder. The results were consistent in longitudinal settings.
Conclusion
Exposure to PAHs mediated the association between tobacco smoking and alcohol use disorder. PAH exposure from tobacco may increase the risk of addictive disorders.
7.Polycyclic Aromatic Hydrocarbons Mediate the Association between Tobacco Smoking and Alcohol Use Disorder
Dongkyu LEE ; Mun-Joo BAE ; Mi-Ji KIM ; Sung Soo OH ; Ki Soo PARK ; Chan Joo LEE ; Sungha PARK ; Seung-Koo LEE ; Sang-Baek KOH ; Sun Jae JUNG ; Changsoo KIM ; Jaelim CHO
Yonsei Medical Journal 2024;65(12):752-760
Purpose:
Smoking is causally related to alcohol use disorder. Although polycyclic aromatic hydrocarbons (PAHs) are major neurotoxic pollutants in tobacco smoke, evidence is lacking on the role of PAHs in the relationship between smoking and alcohol use disorder. This study investigated the types of PAHs associated with smoking and whether exposure to those PAHs mediated the effect of smoking on alcohol use disorder.
Materials and Methods:
A total of 968 male firefighters were analyzed. Smoking history and cumulative pack-years were obtained using self-reported questionnaires. Alcohol use disorder was defined using the Alcohol Use Disorder Identification Test.PAH exposure was assessed by urinary metabolites. Regression analyses were performed between exposure (smoking), outcome (alcohol use disorder), and mediator (PAH metabolites) variables. A mediation analysis was performed to test the indirect effect of PAH metabolites on the association between smoking and alcohol use disorder. All analyses were repeated for 770 participants who were followed up after 2 years, while alcohol use disorder was redefined from follow-up data ensuring the temporal sequence of the variables.
Results:
Both 2-naphthol [β=0.78, 95% confidence interval (CI): 0.59–0.98] and 2-hydroxyfluorene (β=0.69, 95% CI: 0.56–0.82) were associated with smoking history. Furthermore, 2-naphthol and 2-hydroxyfluorene mediated the associations of smoking history (proportion mediated: 14.2%, 23.6% respectively) or cumulative pack-years (proportion mediated: 14.4%, 25.4% respectively) with alcohol use disorder. The results were consistent in longitudinal settings.
Conclusion
Exposure to PAHs mediated the association between tobacco smoking and alcohol use disorder. PAH exposure from tobacco may increase the risk of addictive disorders.
8.Polycyclic Aromatic Hydrocarbons Mediate the Association between Tobacco Smoking and Alcohol Use Disorder
Dongkyu LEE ; Mun-Joo BAE ; Mi-Ji KIM ; Sung Soo OH ; Ki Soo PARK ; Chan Joo LEE ; Sungha PARK ; Seung-Koo LEE ; Sang-Baek KOH ; Sun Jae JUNG ; Changsoo KIM ; Jaelim CHO
Yonsei Medical Journal 2024;65(12):752-760
Purpose:
Smoking is causally related to alcohol use disorder. Although polycyclic aromatic hydrocarbons (PAHs) are major neurotoxic pollutants in tobacco smoke, evidence is lacking on the role of PAHs in the relationship between smoking and alcohol use disorder. This study investigated the types of PAHs associated with smoking and whether exposure to those PAHs mediated the effect of smoking on alcohol use disorder.
Materials and Methods:
A total of 968 male firefighters were analyzed. Smoking history and cumulative pack-years were obtained using self-reported questionnaires. Alcohol use disorder was defined using the Alcohol Use Disorder Identification Test.PAH exposure was assessed by urinary metabolites. Regression analyses were performed between exposure (smoking), outcome (alcohol use disorder), and mediator (PAH metabolites) variables. A mediation analysis was performed to test the indirect effect of PAH metabolites on the association between smoking and alcohol use disorder. All analyses were repeated for 770 participants who were followed up after 2 years, while alcohol use disorder was redefined from follow-up data ensuring the temporal sequence of the variables.
Results:
Both 2-naphthol [β=0.78, 95% confidence interval (CI): 0.59–0.98] and 2-hydroxyfluorene (β=0.69, 95% CI: 0.56–0.82) were associated with smoking history. Furthermore, 2-naphthol and 2-hydroxyfluorene mediated the associations of smoking history (proportion mediated: 14.2%, 23.6% respectively) or cumulative pack-years (proportion mediated: 14.4%, 25.4% respectively) with alcohol use disorder. The results were consistent in longitudinal settings.
Conclusion
Exposure to PAHs mediated the association between tobacco smoking and alcohol use disorder. PAH exposure from tobacco may increase the risk of addictive disorders.
9.Polycyclic Aromatic Hydrocarbons Mediate the Association between Tobacco Smoking and Alcohol Use Disorder
Dongkyu LEE ; Mun-Joo BAE ; Mi-Ji KIM ; Sung Soo OH ; Ki Soo PARK ; Chan Joo LEE ; Sungha PARK ; Seung-Koo LEE ; Sang-Baek KOH ; Sun Jae JUNG ; Changsoo KIM ; Jaelim CHO
Yonsei Medical Journal 2024;65(12):752-760
Purpose:
Smoking is causally related to alcohol use disorder. Although polycyclic aromatic hydrocarbons (PAHs) are major neurotoxic pollutants in tobacco smoke, evidence is lacking on the role of PAHs in the relationship between smoking and alcohol use disorder. This study investigated the types of PAHs associated with smoking and whether exposure to those PAHs mediated the effect of smoking on alcohol use disorder.
Materials and Methods:
A total of 968 male firefighters were analyzed. Smoking history and cumulative pack-years were obtained using self-reported questionnaires. Alcohol use disorder was defined using the Alcohol Use Disorder Identification Test.PAH exposure was assessed by urinary metabolites. Regression analyses were performed between exposure (smoking), outcome (alcohol use disorder), and mediator (PAH metabolites) variables. A mediation analysis was performed to test the indirect effect of PAH metabolites on the association between smoking and alcohol use disorder. All analyses were repeated for 770 participants who were followed up after 2 years, while alcohol use disorder was redefined from follow-up data ensuring the temporal sequence of the variables.
Results:
Both 2-naphthol [β=0.78, 95% confidence interval (CI): 0.59–0.98] and 2-hydroxyfluorene (β=0.69, 95% CI: 0.56–0.82) were associated with smoking history. Furthermore, 2-naphthol and 2-hydroxyfluorene mediated the associations of smoking history (proportion mediated: 14.2%, 23.6% respectively) or cumulative pack-years (proportion mediated: 14.4%, 25.4% respectively) with alcohol use disorder. The results were consistent in longitudinal settings.
Conclusion
Exposure to PAHs mediated the association between tobacco smoking and alcohol use disorder. PAH exposure from tobacco may increase the risk of addictive disorders.
10.Clinical Outcome after Everolimus-Eluting Stent Implantation for Small Vessel Coronary Artery Disease: XIENCE Asia Small Vessel Study
Doo Sun SIM ; Dae Young HYUN ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Myung Ho JEONG ; Sang Rok LEE ; Jei Keon CHAE ; Keun Ho PARK ; Young Youp KOH ; Kyeong Ho YUN ; Seok Kyu OH ; Seung Jae JOO ; Sun Ho HWANG ; Jong Pil PARK ; Jay Young RHEW ; Su Hyun KIM ; Jang Hyun CHO ; Seung Uk LEE ; Dong Goo KANG
Chonnam Medical Journal 2024;60(1):78-86
There are limited data on outcomes after implantation of everolimus-eluting stents (EES) in East Asian patients with small vessel coronary lesions. A total of 1,600 patients treated with XIENCE EES (Abbott Vascular, CA, USA) were divided into the small vessel group treated with one ≤2.5 mm stent (n=119) and the non-small vessel group treated with one ≥2.75 mm stent (n=933). The primary end point was a patient-oriented composite outcome (POCO), a composite of all-cause death, myocardial infarction (MI), and any repeat revascularization at 12 months. The key secondary end point was a device-oriented composite outcome (DOCO), a composite of cardiovascular death, target-vessel MI, and target lesion revascularization at 12 months. The small vessel group was more often female, hypertensive, less likely to present with ST-elevation MI, and more often treated for the left circumflex artery, whereas the non-small vessel group more often had type B2/C lesions, underwent intravascular ultrasound, and received unfractionated heparin. In the propensity matched cohort, the mean stent diameter was 2.5±0.0 mm and 3.1±0.4 mm in the small and non-small vessel groups, respectively. Propensity-adjusted POCO at 12 months was 6.0% in the small vessel group and 4.3% in the non-small vessel group (p=0.558). There was no significant difference in DOCO at 12 months (small vessel group: 4.3% and non-small vessel group: 1.7%, p=0.270).Outcomes of XIENCE EES for small vessel disease were comparable to those for non-small vessel disease at 12-month clinical follow-up in real-world Korean patients.

Result Analysis
Print
Save
E-mail