1.Coagulopathy in patients who experience snakebite.
Jae Seok KIM ; Jae Won YANG ; Min Soo KIM ; Seung Tae HAN ; Bi Ro KIM ; Myung Sang SHIN ; Jong In LEE ; Byoung Geun HAN ; Seung Ok CHOI
The Korean Journal of Internal Medicine 2008;23(2):94-99
BACKGROUND/AIMS: Coagulopathy is a common complication of snakebite, but there is little information on the clinical importance of coagulopathy. We analyzed the characteristics of coagulopathy after envenomation. METHODS: Ninety-eight patients who experienced snakebite were enrolled in this study. We divided all the patients into three groups by the ISTH DIC scoring system: the normal, simple coagulopathy and DIC groups. The coagulopathy group included both the simple coagulopathy and DIC groups. We then conducted a case-control study. RESULTS: There was a significant decrease in the Hct, protein, albumin, ALP and cholesterol levels in the coagulopathy group, and only the cholesterol level was deceased in the DIC group (p<0.05). Leukocytosis and rhabdomyolysis were significantly associated with coagulopathy, and hemolysis and rhabdomyolysis were associated with DIC (p<0.05). The presence of rhabdomyolysis was considered a risk factor for coagulopathy (p<0.05). These conditions continued for up to six to seven days after the snakebite. CONCLUSIONS: Evaluation of coagulopathy with using these characteristics is helpful to properly manage the patients who experience snakebite.
Animals
;
Blood Coagulation Disorders/*etiology
;
Case-Control Studies
;
Female
;
Hemolysis/drug effects
;
Humans
;
Incidence
;
Leukocytosis/etiology
;
Male
;
Retrospective Studies
;
Rhabdomyolysis/etiology
;
Risk Factors
;
Snake Bites/*complications
2.Fertilization and pregnancy potential of immature oocytes from stimulated intracytoplasmic sperm injection cycles.
Seung Bi SHIN ; Jae Won CHO ; Sun Hee LEE ; Kwang Moon YANG ; Chun Kyu LIM ; Hyoung Song LEE
Clinical and Experimental Reproductive Medicine 2013;40(1):7-11
OBJECTIVE: We evaluated the fertilization potential of immature oocytes obtained from controlled ovarian hyperstimulation cycles of patients undergoing ICSI. METHODS: We retrospectively analyzed 463 ICSI cycles containing at least one immature oocyte at oocyte denudation. ICSI was performed on mature oocytes at oocyte denudation (metaphase-II [MII] oocytes) and the oocytes that extruded the first polar body between oocyte denudation and ICSI (MI-MII oocytes). Fertilization and early embryonic development were compared between MII and MI-MII oocytes. To investigate the pregnancy potential of MI-MII oocytes, the pregnancy outcome was analyzed in 24 ICSI cycles containing only immature oocytes at retrieval. RESULTS: The fertilization rate of MI-MII oocytes (37.0%) was significantly lower than that of MII oocytes (72.3%). The rates of delayed embryos and damaged embryos did not significantly differ. Eighty-one immature oocytes were retrieved in 24 cycles that retrieved only immature oocytes and 61 (75.3%) of them were in the MI stage. ICSI was performed on 36 oocytes (59.0%) that extruded the first polar body before ICSI and nine MI-MII oocytes (25.0%) were fertilized. Embryo transfers were performed in five cycles. Pregnancy was observed in one cycle, but it ended in biochemical pregnancy. CONCLUSION: In ICSI cycles, oocytes that extruded the first polar body between denudation and ICSI can be used as a source of oocytes for sperm injection. However, their fertilization and pregnancy potential are lower than that of mature oocytes. Therefore, ovarian stimulation should be performed carefully for mature oocytes obtained at retrieval, especially in cycles with a small number of retrieved oocytes.
Embryo Transfer
;
Embryonic Development
;
Embryonic Structures
;
Female
;
Fertilization
;
Humans
;
Oocytes
;
Ovulation Induction
;
Polar Bodies
;
Pregnancy
;
Pregnancy Outcome
;
Retrospective Studies
;
Sperm Injections, Intracytoplasmic
;
Spermatozoa
3.Free-Breathing Motion-Corrected Single-Shot Phase-Sensitive Inversion Recovery Late-Gadolinium-Enhancement Imaging: A Prospective Study of Image Quality in Patients with Hypertrophic Cardiomyopathy
Min Jae CHA ; Iksung CHO ; Joonhwa HONG ; Sang-Wook KIM ; Seung Yong SHIN ; Mun Young PAEK ; Xiaoming BI ; Sung Mok KIM
Korean Journal of Radiology 2021;22(7):1044-1053
Objective:
Motion-corrected averaging with a single-shot technique was introduced for faster acquisition of late-gadoliniumenhancement (LGE) cardiovascular magnetic resonance (CMR) imaging while free-breathing. We aimed to evaluate the image quality (IQ) of free-breathing motion-corrected single-shot LGE (moco-ss-LGE) in patients with hypertrophic cardiomyopathy (HCM).
Materials and Methods:
Between April and December 2019, 30 patients (23 men; median age, 48.5; interquartile range [IQR], 36.5–61.3) with HCM were prospectively enrolled. Breath-held single-shot LGE (bh-ss-LGE) and free-breathing mocoss-LGE images were acquired in random order on a 3T MR system. Semi-quantitative IQ scores, contrast-to-noise ratios (CNRs), and quantitative size of myocardial scar were assessed on pairs of bh-ss-LGE and moco-ss-LGE. The mean ± standard deviation of the parameters was obtained. The results were compared using the Wilcoxon signed-rank test.
Results:
The moco-ss-LGE images had better IQ scores than the bh-ss-LGE images (4.55 ± 0.55 vs. 3.68 ± 0.45, p < 0.001). The CNR of the scar to the remote myocardium (34.46 ± 11.85 vs. 26.13 ± 10.04, p < 0.001), scar to left ventricle (LV) cavity (13.09 ± 7.95 vs. 9.84 ± 6.65, p = 0.030), and LV cavity to remote myocardium (33.12 ± 15.53 vs. 22.69 ± 11.27, p < 0.001) were consistently greater for moco-ss-LGE images than for bh-ss-LGE images. Measurements of scar size did not differ significantly between LGE pairs using the following three different quantification methods: 1) full width at half-maximum method; 23.84 ± 12.88% vs. 24.05 ± 12.81% (p = 0.820), 2) 6-standard deviation method, 15.14 ± 10.78% vs. 15.99 ± 10.99% (p = 0.186), and 3) 3-standard deviation method; 36.51 ± 17.60% vs. 37.50 ± 17.90% (p = 0.785).
Conclusion
Motion-corrected averaging may allow for superior IQ and CNRs with free-breathing in single-shot LGE imaging, with a herald of free-breathing moco-ss-LGE as the scar imaging technique of choice for clinical practice.
4.Free-Breathing Motion-Corrected Single-Shot Phase-Sensitive Inversion Recovery Late-Gadolinium-Enhancement Imaging: A Prospective Study of Image Quality in Patients with Hypertrophic Cardiomyopathy
Min Jae CHA ; Iksung CHO ; Joonhwa HONG ; Sang-Wook KIM ; Seung Yong SHIN ; Mun Young PAEK ; Xiaoming BI ; Sung Mok KIM
Korean Journal of Radiology 2021;22(7):1044-1053
Objective:
Motion-corrected averaging with a single-shot technique was introduced for faster acquisition of late-gadoliniumenhancement (LGE) cardiovascular magnetic resonance (CMR) imaging while free-breathing. We aimed to evaluate the image quality (IQ) of free-breathing motion-corrected single-shot LGE (moco-ss-LGE) in patients with hypertrophic cardiomyopathy (HCM).
Materials and Methods:
Between April and December 2019, 30 patients (23 men; median age, 48.5; interquartile range [IQR], 36.5–61.3) with HCM were prospectively enrolled. Breath-held single-shot LGE (bh-ss-LGE) and free-breathing mocoss-LGE images were acquired in random order on a 3T MR system. Semi-quantitative IQ scores, contrast-to-noise ratios (CNRs), and quantitative size of myocardial scar were assessed on pairs of bh-ss-LGE and moco-ss-LGE. The mean ± standard deviation of the parameters was obtained. The results were compared using the Wilcoxon signed-rank test.
Results:
The moco-ss-LGE images had better IQ scores than the bh-ss-LGE images (4.55 ± 0.55 vs. 3.68 ± 0.45, p < 0.001). The CNR of the scar to the remote myocardium (34.46 ± 11.85 vs. 26.13 ± 10.04, p < 0.001), scar to left ventricle (LV) cavity (13.09 ± 7.95 vs. 9.84 ± 6.65, p = 0.030), and LV cavity to remote myocardium (33.12 ± 15.53 vs. 22.69 ± 11.27, p < 0.001) were consistently greater for moco-ss-LGE images than for bh-ss-LGE images. Measurements of scar size did not differ significantly between LGE pairs using the following three different quantification methods: 1) full width at half-maximum method; 23.84 ± 12.88% vs. 24.05 ± 12.81% (p = 0.820), 2) 6-standard deviation method, 15.14 ± 10.78% vs. 15.99 ± 10.99% (p = 0.186), and 3) 3-standard deviation method; 36.51 ± 17.60% vs. 37.50 ± 17.90% (p = 0.785).
Conclusion
Motion-corrected averaging may allow for superior IQ and CNRs with free-breathing in single-shot LGE imaging, with a herald of free-breathing moco-ss-LGE as the scar imaging technique of choice for clinical practice.
5.Practice guideline for the performance of breast ultrasound elastography.
Su Hyun LEE ; Jung Min CHANG ; Nariya CHO ; Hye Ryoung KOO ; Ann YI ; Seung Ja KIM ; Ji Hyun YOUK ; Eun Ju SON ; Seon Hyeong CHOI ; Shin Ho KOOK ; Jin CHUNG ; Eun Suk CHA ; Jeong Seon PARK ; Hae Kyoung JUNG ; Kyung Hee KO ; Hye Young CHOI ; Eun Bi RYU ; Woo Kyung MOON
Ultrasonography 2014;33(1):3-10
Ultrasound (US) elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS) US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.
Breast*
;
Consensus
;
Elasticity Imaging Techniques*
;
Information Systems
;
Mass Screening
;
Ultrasonography*
6.SEALONE (Safety and Efficacy of Coronary Computed Tomography Angiography with Low Dose in Patients Visiting Emergency Room) trial: study protocol for a randomized controlled trial.
Joonghee KIM ; Joon Won KANG ; Kyuseok KIM ; Sang Il CHOI ; Eun Ju CHUN ; Yeo Goon KIM ; Won Young KIM ; Dong Woo SEO ; Jonghwan SHIN ; Huijai LEE ; Kwang Nam JIN ; Soyeon AHN ; Seung Sik HWANG ; Kwang Pyo KIM ; Ru Bi JEONG ; Sang Ook HA ; Byungho CHOI ; Chang Hwan YOON ; Jung Won SUH ; Hack Lyoung KIM ; Ju Kyoung KIM ; Sujin JANG ; Ji Seon SEO
Clinical and Experimental Emergency Medicine 2017;4(4):208-213
OBJECTIVE: Chest pain is one of the most common complaints in the emergency department (ED). Cardiac computed tomography angiography (CCTA) is a frequently used tool for the early triage of patients with low- to intermediate-risk acute chest pain. We present a study protocol for a multicenter prospective randomized controlled clinical trial testing the hypothesis that a low-dose CCTA protocol using prospective electrocardiogram (ECG)-triggering and limited-scan range can provide sufficient diagnostic safety for early triage of patients with acute chest pain. METHODS: The trial will include 681 younger adult (aged 20 to 55) patients visiting EDs of three academic hospitals for acute chest pain or equivalent symptoms who require further evaluation to rule out acute coronary syndrome. Participants will be randomly allocated to either low-dose or conventional CCTA protocol at a 2:1 ratio. The low-dose group will undergo CCTA with prospective ECG-triggering and restricted scan range from sub-carina to heart base. The conventional protocol group will undergo CCTA with retrospective ECG-gating covering the entire chest. Patient disposition is determined based on computed tomography findings and clinical progression and all patients are followed for a month. The primary objective is to prove that the chance of experiencing any hard event within 30 days after a negative low-dose CCTA is less than 1%. The secondary objectives are comparisons of the amount of radiation exposure, ED length of stay and overall cost. RESULTS AND CONCLUSION: Our low-dose protocol is readily applicable to current multi-detector computed tomography devices. If this study proves its safety and efficacy, dose-reduction without purchasing of expensive newer devices would be possible.
Acute Coronary Syndrome
;
Adult
;
Angiography*
;
Chest Pain
;
Coronary Angiography
;
Electrocardiography
;
Emergencies*
;
Emergency Service, Hospital
;
Heart
;
Humans
;
Length of Stay
;
Prospective Studies
;
Radiation Exposure
;
Retrospective Studies
;
Thorax
;
Triage