1.Rehabilitation of severely worn dentition using Monolithic surveyed restoration and electronic surveying in RPD metal framework fabrication: A case report.
Youngha CHOI ; Hyeong Seob KIM ; Kung Rock KWON ; Ahran PAE ; Kwantae NOH ; Janghyun PAEK ; Seoungjin HONG
The Journal of Korean Academy of Prosthodontics 2018;56(3):243-249
Excessive tooth wear results in unacceptable damage to the occlusal surface and can cause pulpitis, occlusal disharmony, dysfunction, and unesthetic result. Patients with severe attrition have to be classified as several types relative to the vertical dimension of occlusion (VDO) and the interocclusal distance for the prosthetic space. The patient in this case was a 80 - year - old woman who lost support of posterior occlusion and collapsed of the occlusal plane due to confrontation of the opposing teeth, accompanied by an increase in the number of remaining bristles, resulting in a loss of intermaxillary space for prosthesis. In this case, treatment with increased vertical dimension may have stability if the increase in vertical occlusal height is minimized within the required range, and a stable occlusal contact is provided after an increased vertical occlusal height stabilization period. After the new VDO had been confirmed under interim fixed restorations, definitive fixed restorations were produced. Through these treatment processes, we obtain satisfactory results that are functional and aesthetically pleasing.
Dental Occlusion
;
Dentition*
;
Female
;
Humans
;
Prostheses and Implants
;
Pulpitis
;
Rehabilitation*
;
Tooth
;
Tooth Wear
;
Vertical Dimension
2.Retreatment of fractured implant overdenture due to long-term maintenance failure.
Minjee KIM ; Seoungjin HONG ; Janghyun PAEK ; Kwantae NOH ; Ahran PAE ; Hyeong Seob KIM ; Kung Rock KWON
The Journal of Korean Academy of Prosthodontics 2018;56(3):235-242
Periodontal and prosthodontic maintenance of implant overdenture is a very important factor for the long term success of the prosthesis and implants. Failure of maintenance can lead to prosthetic failure due to peri-implant bone loss and fracture and wear of the prosthesis or components. In this case, the existing gold milled bars were reconstructed with cobalt chrome milled bar in a manner that does not interfere with the external shape for the retreatment of fractured implant overdenture by maintenance failure. Two implants of mandible were selected strategically and the CM LOC attachments were connected to the two implants, and implant overdentures were fabricated. As a result, prosthesis with a functional and esthetic design that facilitates good hygiene management of the patient was delivered, which is advantageous for long term maintenance, and regular check-ups were scheduled for proper maintenance.
Cobalt
;
Denture, Overlay*
;
Humans
;
Hygiene
;
Mandible
;
Prostheses and Implants
;
Retreatment*
3.Utilization of digital technology in fabricating mandibular implant overdenture for skeletal class II edentulous patient: A case report
Yeun Yi LEE ; Seoungjin HONG ; Janghyun PAEK ; Kwantae NOH ; Kung Rock KWON
The Journal of Korean Academy of Prosthodontics 2019;57(4):364-373
Unlike class I patients, skeletal class II patients have unstable occlusion thus leading to instability of mandibular complete denture. Therefore, mandibular implant overdenture has been the standard of care due to its advantages in stability and retention. The types of attachments can be divided into two categories: solitary and bar type. The indications vary between two categories. In this clinical report, digital technology was utilized from the implant planning to the choice of appropriate attachment. Implants were placed at the desired location as previously planned in terms of angle and depth. Maxillary removable partial denture and mandibular implant overdenture are expected to have fair prognosis.
Denture, Complete
;
Denture, Overlay
;
Denture, Partial, Removable
;
Humans
;
Prognosis
;
Spatial Analysis
;
Standard of Care
4.Evaluation of suitability and stability in a skeletal Class III complete denture patient with flabby tissue: A case report.
Junsuk LEE ; Seoungjin HONG ; Janghyun PAEK ; Kwantae NOH ; Ahran PAE ; Hyeong Seob KIM ; Kung Rock KWON
The Journal of Korean Academy of Prosthodontics 2018;56(4):295-301
To obtain denture retention, support, and stability in Class III edentulous cases with flat alveolar ridges and extensive flabby tissue is very difficult. The patient was a 72-year-old male who wore ill-fitting 20 year old dentures made by non-medical institutions. There was flabby tissue on the maxillary anterior ridge. The patient showed Angle Class III skeletal relationship with severe protruded mandible. First, temporary dentures were fabricated to restore the masticatory function, and final dentures were made through non- pressure impression technique and careful the arrangement of the posterior resin teeth. Improvement of the retention and stability of the denture during the occlusal force application is reported.
Aged
;
Bite Force
;
Denture Retention
;
Denture, Complete*
;
Dentures
;
Humans
;
Male
;
Malocclusion
;
Malocclusion, Angle Class III
;
Mandible
;
Tooth