1.Multiple Hemangioendotheliomas of the Spinal Cord and Cauda Equina: Case Report.
Jin Hong JEON ; Sung Min KIM ; Seoung Wan CHAE ; Sun Kil CHOI
Journal of Korean Neurosurgical Society 2003;33(3):320-322
A case of multiple hemangioendothelioma of the cauda equina nerve roots and conus medullaris is described. This case is the first report of intradural multiple hemangioendothelioma in Korea. A 74-year-old woman presented with a 4-month history of progressive bilateral leg weakness and lancinating leg pain especially at night. Magnetic resonance image revealed multiple enhancing nodular masses in the cauda equina nerve roots and pial surface of the conus medullaris. We performed total removal of conus medullaris mass and partial removal of two nerve rootlets masses. Two lesions were histologically examined and found to be hemangioendotheliomas
Aged
;
Cauda Equina*
;
Conus Snail
;
Female
;
Hemangioendothelioma*
;
Humans
;
Korea
;
Leg
;
Spinal Cord*
2.Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method
Suji LEE ; Seoung Jin HONG ; Janghyun PAEK ; Ahran PAE ; Kung Rock KWON ; Kwantae NOH
The Journal of Advanced Prosthodontics 2019;11(1):55-64
PURPOSE: The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS: The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at α=.05. RESULTS: No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P < .05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P < .05). CONCLUSION: The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.
Denture Bases
;
Dentures
;
Fungi
;
Methods
;
Printing, Three-Dimensional
;
Sutures
3.A Comparison of Lumbar Lordosis in Asymptomatic and Low back pain group
Hak Jin MIN ; Keun Woo KIM ; Pil Gu LEE ; Yong Hoon KIM ; Ui Seoung YOON ; Sung Hong AN
The Journal of the Korean Orthopaedic Association 1995;30(1):83-88
To evaluate a relationship of lumbar lordosis between asymptomatic group and low back pain group, lumbar lordotic angle was measured from standing lateral lumbosacral roentogenogram of 360 men and women between 20 and 49 years of age. We excluded the patients with back deformity, moderate to severe degenerative change of lumbosacral spine, leg length discrepency, and degenerative change of lower leg in both groups. The lumber lordodsis angle was measured with two ways, lumbosacral angle and lumbolumbar angle respectively. Two angles have a line parallel to the top of second lumbar vertebra as the proximal boundary. The distal border of the lumbosacral angle is a line parallel to the top of sacrum. The distal border of the lumbolumbar angle is a line parallel to the bottom of fifth lumbar vertebra. With statistical analysis of the results, we came to followiing conclusion: 1. The mean lumbolumbar angle was 33.62° +0.62° (SEM: standard error of the mean) and the mean lumbosacral angle was 49.91° +0.59° in asymptomatic group. 2. The mean lumbolumbar angle was 34.79° +0.68° and the mean lumbosacral angle was 50.35° +0.76° in low back pain group. 3. No significant difference in lumbosacral and lumbolsacral angle between asymptomatic and low back pain group was identified using general linear models procedure(P>0.5). 4. Analyzing the data by sex, no significant difference in lumbosacral and lumbosacral angle was identified using general linear models procudure(P>0.05). 5. Analyzing the data by age group, no significant difference in lumbosacral angle was identified (P>0.05), but significant difference in lumbolsacral angle was identified using general linear models procedure(P=0.0045).
Animals
;
Congenital Abnormalities
;
Female
;
Humans
;
Leg
;
Linear Models
;
Lordosis
;
Low Back Pain
;
Male
;
Sacrum
;
Spine
4.Prosthetic reconstruction with an obturator using swing-lock attachment for a patient underwent maxillectomy: A clinical report.
Dong Jae SEONG ; Seoung Jin HONG ; Seung Ryong HA ; Young Gi HONG ; Hyo Won KIM
The Journal of Advanced Prosthodontics 2016;8(5):411-416
Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth.
Braces
;
Crowns
;
Denture Precision Attachment
;
Female
;
Humans
;
Maxilla
;
Melanoma
;
Middle Aged
;
Palatal Obturators
;
Prognosis
;
Prostheses and Implants
;
Tooth
5.A Mycobacterium Chelonae Subsp. abscessus Wound Infection After Percutaneous Endoscopic Gastrostomy.
Sang Ho LEE ; Ku Yeoup KIM ; Seoung Pyo HONG ; Myung Jae KIM ; Mun Ho YANG ; Jin Tae SEOU
Korean Journal of Medicine 1997;53(6):842-846
Mycobacterium chelonae is a rapidly growing organism that has been found in water, soil, and dust. Although it can colonize healthy persons without sequelae, it can also cause skin and soft tissue infections, pulmonary infections and other sequelaes and rarely, disseminated disease in immunocompromised patients. But, infections due to rapidly growing mycobacteria are probably markedly underdiagnosed and these organisms are capable of causing a wide spectrum of clinical disease. We experienced a case of wound infection with M. chelonae after percutaneous endoscopic gastrostomy and report with review of literatures.
Colon
;
Dust
;
Gastrostomy*
;
Humans
;
Immunocompromised Host
;
Mycobacterium chelonae*
;
Mycobacterium*
;
Skin
;
Soft Tissue Infections
;
Soil
;
Wound Infection*
;
Wounds and Injuries*
6.Fabrication of complete dentures by conventional method and CAD/CAM milling: A case report
Youngchul JUNG ; Junsuk LEE ; Seoung Jin HONG ; Kwantae NOH ; Hyeong Seob KIM ; Ahran PAE
The Journal of Korean Academy of Prosthodontics 2019;57(3):296-303
In edentulous patient, not only mastication and pronunciation but also esthetics are compromised. By restoring an edentulous patient with complete dentures, masticatory function and esthetics can be rehabilitated. The advantages of the dentures using CAD/CAM are that they can be reconstructed ubiquitously with stored data, and the strength and density of CAD/CAM material are clinically acceptable. In this clinical report, interocclusal record was taken in a conventional manner and then two lab processing procedures were performed: conventional method and CAD/CAM method. Two types of processing procedures were compared and evaluated. Fair clinical results were obtained in both ways, satisfying the patient.
Denture Bases
;
Denture, Complete
;
Dentures
;
Esthetics
;
Humans
;
Mastication
;
Methods
7.Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report
Taeyoon KIM ; Jun Suk LEE ; Seoung Jin HONG ; Hyeong Seob KIM ; Kung Rock KWON
The Journal of Korean Academy of Prosthodontics 2019;57(3):288-295
Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There were limitations of extensive implant prosthesis because conventional casting method generate contraction error of long span prosthesis. However, Computer-aided design/Computer-aided manufacturing (CAD/CAM) technology of 3D printing and milling metal framework can overcome those limitations. This case is a full mouth rehabilitation using extensive implant fixed prosthesis. Removable interim prosthesis was made for esthetic, functional evaluation and a guide for implant insertion. After the insertion, implant fixed interim prosthesis was delivered. After additional evaluation and adjustment, final prosthesis was designed with CAD, the fabricated with CAM. Milling technique was used for anterior screw type implant superstructure and 3D printing technique was used for the anterior and posterior implant copings. Fit of the final restoration was favorable. The practitioner and patient were both esthetically and functionally satisfied with the final result.
Dental Caries
;
Humans
;
Methods
;
Mouth Rehabilitation
;
Mouth
;
Printing, Three-Dimensional
;
Prostheses and Implants
8.Full mouth rehabilitation of a patient with severe tooth erosion with a digital crown lengthening guide
Yunjae PARK ; Seoung Jin HONG ; Janghyun PAEK ; Ahran PAE ; Hyeong Seob KIM
The Journal of Korean Academy of Prosthodontics 2019;57(3):280-287
In the oral cavity, the teeth undergo wear and corrosion throughout their lives. Progressive and constant tooth wear is a natural phenomenon of aging, but wear and corrosion due to specific factors are pathological factors. It can cause pathological damage of the occlusal surface, aesthetic problems, dimensional loss and jaw joint disorders. This case is a 26-year-old female patient with general tooth abrasion and erosion on the entire dentition. Diagnostic wax-up was fabricated based on the information including digital facial analysis, physiological stabilization, and evaluation of anterior crown length. Through the digital analysis, the necessary guides for crown lengthening were prepared and the mastication function and esthetics were evaluated by using temporary crowns. Definitive prosthesis was fabricated with the zirconia restorations. The results were satisfactory when they were observed 3 months of follow-up.
Adult
;
Aging
;
Corrosion
;
Crown Lengthening
;
Crowns
;
Dentition
;
Esthetics
;
Female
;
Follow-Up Studies
;
Humans
;
Jaw
;
Joints
;
Mastication
;
Mouth Rehabilitation
;
Mouth
;
Prostheses and Implants
;
Tooth Abrasion
;
Tooth Erosion
;
Tooth Wear
;
Tooth
9.Rehabilitation of fully edentulous patient using Ceramill full denture system (FDS)
Younghoo LEE ; Kung Rock KWON ; Ahran PAE ; Kwantae NOH ; Janghyun PAEK ; Seoung Jin HONG
The Journal of Korean Academy of Prosthodontics 2019;57(3):232-237
CAD/CAM technology has already been used in most areas of prosthetics. The range of CAD/CAM application in denture fabricating process has been gradually increasing since the CAD/CAM technology was introduced for the fabrication of complete dentures in 1994. This paper describes a technique that combines conventional and CAD/CAM technology for the fabrication of complete dentures: the master casts from a conventional impression techniques were scanned first, and the wax denture was fabricated using Amann Girrbach's Ceramill full denture system (fds). The purpose of this paper is to introduce the case in which making an esthetically and functionally satisfied denture in shorter time is possible with CAD/CAM technology.
Denture, Complete
;
Dentures
;
Humans
;
Rehabilitation
10.A novel retentive type of dental implant prosthesis: marginal fitness of the cementlessdouble crown type implant prosthesis evaluated by bacterial penetration and viability
Seoung-Jin HONG ; Kung-Rock KWON ; Eun-Young JANG ; Ji-Hoi MOON
The Journal of Advanced Prosthodontics 2020;12(4):233-238
. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenolcement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crownabutment interface were collected by washing with 500 μL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used tomeasure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cementretained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into theabutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.