1.Defect Size-Based Comparative Analysis of Treatment Modalities for Esophagojejunal Anastomotic Leakage Following Gastrectomy
Ba Ool SEONG ; Ji Yong AHN ; Juno YOO ; Chang Seok KO ; Sa-Hong MIN ; Chung Sik GONG ; Beom Su KIM ; Moon-Won YOO ; Jeong Hwan YOOK ; Hee Jin CHOI ; In-Seob LEE
Journal of Gastric Cancer 2026;26(2):295-306
Purpose:
Esophagojejunal anastomotic leakage (EJAL) represents a severe postoperative complication following total or proximal gastrectomy. Treatment strategies include conservative management, endoscopic interventions, and surgery; however, comparative data remain limited. This study aimed to compare clinical outcomes of different strategies to identify the optimal approach based on anastomotic defect size.
Materials and Methods:
This retrospective study reviewed 100 patients diagnosed with EJAL between January 2015 and October 2024. Patients were categorized into four groups:conservative management, endoscopic vacuum-assisted closure (E-VAC), other endoscopic treatments, and surgery. The primary outcomes were leakage duration and length of hospital stay after EJAL diagnosis, whereas the secondary outcome was time to C-reactive protein normalization. Subgroup analyses were performed according to defect size.
Results:
Among the 100 patients, 76 were male and 24 were female, with a mean age of 65.7 years. Conservative treatment was the most common modality (53%), followed by other endoscopic treatments (19%), E-VAC (14%), and surgery (14%). In patients with a defect size <1 cm, conservative treatment was associated with significantly shorter leakage duration (P=0.035) and earlier resumption of diet (P=0.029) compared with endoscopic treatment.Among those with defects ≥2 cm, E-VAC demonstrated the most favorable median outcomes across all variables; however, statistical significance was not achieved because of the small sample size.
Conclusions
Conservative treatment appears to be the most effective treatment strategy for EJAL with anastomotic defects <1 cm. For larger defects (≥2 cm), E-VAC may offer clinical benefit, although further studies are needed to confirm its efficacy. These findings highlight the importance of individualized treatment selection based on defect size.
2.Diagnostic Performance and Clinical Implications of the “Probable Hepatocellular Carcinoma” Category in the Korean Liver Cancer Association-National Cancer Center Korea Guidelines v2022
Jeong Hee YOON ; Jin-Young CHOI ; Young Kon KIM ; Chang Hee LEE ; Jeong Woo KIM ; Won CHANG ; Joon-Il CHOI ; Seung-seob KIM ; Hee Sun PARK ; Eun Sun LEE ; Jeong-Sik YU ; Seong Jin PARK ; Myung-Won YOU ; Myoung-jin JANG ; Beom Jin PARK ; Jeong Min LEE
Korean Journal of Radiology 2026;27(4):318-331
Objective:
To evaluate the diagnostic performance of the “probable hepatocellular carcinoma (HCC)” category in the Korean Liver Cancer Association-National Cancer Center (KLCA-NCC) v2022 guidelines.
Materials and Methods:
This multicenter retrospective study included patients at risk of HCC who underwent gadoxetic acid-enhanced MRI between January 2015 and June 2018; a subgroup of these patients also underwent liver CT. Eligible patients had at least one non-cystic lesion (≥10 mm) with a reference standard. Four radiologists interpreted the images independently and the results were pooled. The performance of “definite HCC” and “probable HCC” together and “probable HCC” alone were compared between v2018 and v2022.
Results:
A total of 2,237 patients (1,666 men; mean age, 59 ± 11 years) with 2,445 lesions were included. In v2022, 1.5% (143/9,780) of the lesions were additionally categorized as “probable HCC” by four reviewers on MRI; among these, 104 lesions were not HCCs. Focal nodular hyperplasia (FNH) or FNH-like nodules constituted 90.4% (94/104) of the false positives. When “definite HCC” and “probable HCC” were combined, v2022 showed higher sensitivity (83.7% [5,670/6,776] vs. 83.1% [5,631/6,776]) but lower specificity (77.1% [2,316/3,004] vs. 80.6% [2,420/3,004]) than v2018 (P < 0.001). For “probable HCC” alone, v2022 showed a lower positive predictive value (PPV) than v2018 (64.1% [373/582] vs. 76.1% [334/439], P < 0.001). In v2022, lesions with non-rim arterial-phase hyperenhancement (APHE) showed a lower PPV than those without APHE (42.3% [91/215] vs. 76.8% [282/367], P < 0.001). In the CT subgroup (n = 1,590), 1.6% (99/6,360) of the lesions were reassessed as “probable HCC,” and its PPV was 83.8% (83/99) in v2022 whereas no lesions were classified as “probable HCC” under v2018.
Conclusion
The revised “probable HCC” category in the KLCA-NCC v2022 aligns with updates in the diagnostic flow, demonstrating acceptable performance on MRI and CT. Notably, FNH or FNH-like nodules can be misclassified as “probable HCC” when MRI is used.
3.Feasibility and Preliminary Efficacy of Digital Cognitive Training in Parkinson’s Disease With Mild Cognitive Impairment: A Pilot Study
Dongje LEE ; Hang-Rai KIM ; Yu Jeong PARK ; Yisuh AHN ; Daeho LEE ; Jungyeun LEE ; Su Jin CHUNG ; Seung Yeon KIM ; Yeji HWANG ; Ji Young YUN ; Jin Whan CHO ; Kyum-Yil KWON ; Seong-Beom KOH ; Sung Hoon KANG
Journal of Movement Disorders 2026;19(1):76-80
Objective:
Cognitive impairment is common in patients with Parkinson’s disease (PD), and few pharmacological options are available for treating this condition. We evaluated the effects of a digital cognitive training program (SUPERBRAIN), which was previously shown to be effective in populations at risk of Alzheimer’s disease, on cognitive function in individuals with PD.
Methods:
Twenty-three individuals with PD and mild cognitive impairment (PD-MCI) from four clinics were randomized to the intervention (n=16) or control (n=7) groups. The intervention group completed a 12-week, home-based, tablet-based cognitive training program (25–30 min/day, 7 days/week). Cognitive outcomes were assessed using the Seoul Neuropsychological Screening Battery pre- and post-intervention.
Results:
The adherence rate was 79.36%. The intervention group showed significant improvements in the Seoul Verbal Learning Test (SVLT) delayed recall and the Controlled Oral Word Association Test, while no changes were observed in the control group. Analysis of covariance confirmed greater SVLT improvement in the intervention group (F statistic=7.15, p=0.015, partial η2=0.28).
Conclusion
SUPERBRAIN is feasible and can improve cognitive function in individuals with PD-MCI.
4.Proposal of age definition for early-onset gastric cancer based on the Korean Gastric Cancer Association nationwide survey data: a retrospective observational study
Seong-A JEONG ; Ji Sung LEE ; Ba Ool SEONG ; Seul-gi OH ; Chang Seok KO ; Sa-Hong MIN ; Chung Sik GONG ; Beom Su KIM ; Moon-Won YOO ; Jeong Hwan YOOK ; In-Seob LEE ;
Annals of Surgical Treatment and Research 2025;108(4):245-255
Purpose:
This study aimed to define an optimal age cutoff for early-onset gastric cancer (EOGC) and compare its characteristics with those of late-onset gastric cancer (LOGC) using nationwide survey data.
Methods:
Using data from a nationwide survey, this comprehensive population-based study analyzed data spanning 3 years (2009, 2014, and 2019). The joinpoint analysis and interrupted time series (ITS) methodology were employed to identify age cutoffs for EOGC based on the sex ratio and tumor histology. Clinicopathologic characteristics and surgical outcomes were compared between the EOGC and LOGC groups.
Results:
The age cutoff for defining EOGC was suggested to be 50 years, supported by joinpoint and ITS analyses. Early gastric cancer was predominantly present in the EOGC and LOGC groups. Patients with EOGC comprised 20.3% of the total study cohort and demonstrated a more advanced disease stage compared to patients with LOGC. However, patients with EOGC underwent more minimally invasive surgeries, experienced shorter hospital stays, and had lower postoperative morbidity and mortality rates.
Conclusion
This study proposes an age of ≤50 years as a criterion for defining EOGC and highlights its features compared to LOGC. Further research using this criterion should guide tailored treatment strategies and improve outcomes for young patients with gastric cancer.
5.Appropriateness of multidisciplinary treatment related to the adequacy evaluation of gastric cancer from the surgeon’s point of view: a retrospective cohort study
Ba Ool SEONG ; Seul-Gi OH ; Chang Seok KO ; Sa-Hong MIN ; Chung Sik GONG ; In-Seob LEE ; Beom Su KIM ; Jeong Hwan YOOK ; Moon-Won YOO
Annals of Surgical Treatment and Research 2025;108(4):240-244
Purpose:
Multidisciplinary treatment (MDT) in gastric cancer is an effective approach for establishing treatment plans.However, the appropriateness of using “ratio of MDT” as an item for evaluating the adequacy of gastric cancer treatment in Korea has not been previously researched. The purpose of this study is to verify whether the “ratio of MDT” is appropriate as an item for gastric cancer adequacy evaluation from the surgeon’s perspective.
Methods:
This study involved 142 patients who received MDT at our hospital between December 2015 and January 2023.Patients were divided into 2 groups based on the date when gastric cancer adequacy evaluation was implemented; there were 71 patients before and after the evaluation was conducted, respectively. Based on electronic medical records, the initial plan prepared before the MDT clinic and the final plan prepared after the clinic were compared to determine whether the plan was changed.
Results:
The average age of patients who received MDT before and after the evaluation was 64.8 and 62.2 years, respectively. Overall, 50 and 21 patients were male (70.4%) and female (29.6%), respectively, in both groups. Before the evaluation, 26 patients (36.6%) who received MDT changed their treatment plans after visiting the clinic, and 15 patients (21.1%) who received MDT after the evaluation had their treatment plans modified. Groups who received MDT and changes in treatment plans were significantly correlated (P = 0.042).
Conclusion
Our findings suggest that including the “ratio of MDT” as an item of gastric cancer adequacy evaluation needs reassessment.
6.CORRIGENDUM: Proposal of age definition for early-onset gastric cancer based on the Korean Gastric Cancer Association nationwide survey data: a retrospective observational study
Seong-A JEONG ; Ji Sung LEE ; Ba Ool SEONG ; Seul-gi OH ; Chang Seok KO ; Sa-Hong MIN ; Chung Sik GONG ; Beom Su KIM ; Moon-Won YOO ; Jeong Hwan YOOK ; In-Seob LEE ;
Annals of Surgical Treatment and Research 2025;108(5):331-331
7.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
8.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
9.Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction
Seung Eun BAEK ; Kiyean KIM ; Youn-Kyung CHOI ; Sung-Hun KIM ; Seong-Sik KIM ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):193-201
Objective:
Using finite element method (FEM) analysis of a clear aligner (CA), this study aimed to investigate the effects of varying the edentulous space on canine distal bodily movement during space closure following maxillary first premolar extraction.
Methods:
FEM analysis was used to simulate distal canine bodily movement following maxillary first premolar extraction using CAs. Four CA designs for edentulous spaces were compared: no-pontic, full-pontic, halfpontic, and beam. Three-dimensional models of the tooth components and CA were created. The target was set at a 0.25-mm distal canine movement. Long-term tooth movement was simulated using an iterative calculation method.
Results:
All the groups initially showed crown displacement, distal tipping, and distal rotation.Over time, the movement patterns differed in relation to the design. The no-pontic design exhibited the greatest displacement and tipping. The beam design exhibited the largest initial displacement but showed the lowest displacement and tipping thereafter. Full- and half-pontic designs yielded intermediate results. Significant force reduction was observed immediately after CA application, and was followed by a gradual decrease. The mean tooth-movement achievement rate was approximately 76.7%.
Conclusions
The edentulous space design of the CA substantially affected tooth-movement behavior. An iterative simulation is necessary to evaluate longterm tooth-movement patterns. The beam design demonstrated optimal suitability for bodily movement with minimal tipping. For optimal results, additional setup or overcorrection may be necessary.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail