1.Push-out bond strength and dentinal tubule penetration of different root canal sealers used with coated core materials.
Derya DENIZ SUNGUR ; Nuhan PURALI ; Erdal COŞGUN ; Semra CALT
Restorative Dentistry & Endodontics 2016;41(2):114-120
OBJECTIVES: The aim of this study was to compare the push-out bond strength and dentinal tubule penetration of root canal sealers used with coated core materials and conventional gutta-percha. MATERIALS AND METHODS: A total of 72 single-rooted human mandibular incisors were instrumented with NiTi rotary files with irrigation of 2.5% NaOCl. The smear layer was removed with 17% ethylenediaminetetraacetic acid (EDTA). Specimens were assigned into four groups according to the obturation system: Group 1, EndoRez (Ultradent Product Inc.); Group 2, Activ GP (Brasseler); Group 3, SmartSeal (DFRP Ltd. Villa Farm); Group 4, AH 26 (Dentsply de Trey)/gutta-percha (GP). For push-out bond strength measurement, two horizontal slices were obtained from each specimen (n = 20). To compare dentinal tubule penetration, remaining 32 roots assigned to 4 groups as above were obturated with 0.1% Rhodamine B labeled sealers. One horizontal slice was obtained from the middle third of each specimen (n = 8) and scanned under confocal laser scanning electron microscope. Tubule penetration area, depth, and percentage were measured. Kruskall-Wallis test was used for statistical analysis. RESULTS: EndoRez showed significantly lower push-out bond strength than the others (p < 0.05). No significant difference was found amongst the groups in terms of percentage of sealer penetration. SmartSeal showed the least penetration than the others (p < 0.05). CONCLUSIONS: The bond strength and sealer penetration of resin-and glass ionomer-based sealers used with coated core was not superior to resin-based sealer used with conventional GP. Dentinal tubule penetration has limited effect on bond strength. The use of conventional GP with sealer seems to be sufficient in terms of push-out bond strength.
Dental Pulp Cavity*
;
Dentin*
;
Edetic Acid
;
Glass
;
Gutta-Percha
;
Humans
;
Incisor
;
Rhodamines
;
Smear Layer
2.Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator.
Emel UZUNOGLU ; Ayhan EYMIRLI ; Mehmet Ozgur UYANIK ; Semra CALT ; Emre NAGAS
Restorative Dentistry & Endodontics 2015;40(1):44-49
OBJECTIVES: This study compared the ability of several techniques to remove calcium hydroxide (CH) from the root canal and determined the influence of CH residues on the accuracy of the electronic apex locator. MATERIALS AND METHODS: Root canals of 90 human maxillary lateral incisors with confirmed true working length (TWL) were prepared and filled with CH. The teeth were randomly assigned to one of the experimental groups according to the CH removal technique (n = 14): 0.9% saline; 0.9% saline + master apical file (MAF); 17% ethylenediamine tetraacetic acid (EDTA); 17% EDTA + MAF; 5.25% sodium hypochlorite (NaOCl); 5.25% NaOCl + MAF. Six teeth were used as negative control. After CH removal, the electronic working length was measured using Root-ZX (Morita Corp.) and compared with TWL to evaluate Root-ZX accuracy. All specimens were sectioned longitudinally, and the area of remaining CH (CH) and total canal area were measured using imaging software. RESULTS: The EDTA + MAF and NaOCl + MAF groups showed better CH removal than other groups (p < 0.05). Root-ZX reliability to prevent overestimated working length to be > 85% within a tolerance of +/- 1.0 mm (p < 0.05). There was strong negative correlation between amount of CH residues and EAL accuracy (r = -0.800 for +/- 0.5 mm; r = -0.940 for +/- 1.0 mm). CONCLUSIONS: The mechanical instrumentation improves the CH removal of irrigation solutions although none of the techniques removed the dressing completely. Residues of CH medication in root canals affected the accuracy of Root-ZX adversely.
Bandages*
;
Calcium Hydroxide*
;
Dental Pulp Cavity
;
Edetic Acid
;
Humans
;
Incisor
;
Sodium Hypochlorite
;
Tooth