3.Determination of selenium in whole blood by microwave digestionatomic fluorescence spectrometry.
Chinese Journal of Industrial Hygiene and Occupational Diseases 2015;33(12):932-933
OBJECTIVETo establish a rapid, simple, and accurate method for measuring selenium in whole blood by atomic fluorescence spectrometry.
METHODSThe whole blood samples were treated by microwave digestion and the acids were dispelled. After that the samples were pretreated with 50% hydrochloric acid as a reducing agent. Then the content of selenium in the pretreated samples was measured by hydride generation atomic fluorescence spectrometry.
RESULTSThe calibration curve for selenium is linear in the range of 0~60 μg/L (r=0.9999). The detection limit, relative standard deviation, and recovery rate were 0.133 μg/L, 1.22%~2.08%, and 96.5%~101.8%, respectively.
CONCLUSIONThis method is simple, with less consumption of chemical reagents, less pollution, and enough accuracy and sensitivity for determination of selenium in whole blood samples.
Calibration ; Humans ; Hydrochloric Acid ; Indicators and Reagents ; Limit of Detection ; Microwaves ; Selenium ; blood ; Spectrometry, Fluorescence
4.Comparison of maternal and umbilical cord blood selenium levels in term and preterm infants.
Ramin IRANPOUR ; Ali ZANDIAN ; Majid MOHAMMADIZADEH ; Ashraf MOHAMMADZADEH ; Mahdi BALALI-MOOD ; Mehnosh HAJIHEYDARI
Chinese Journal of Contemporary Pediatrics 2009;11(7):513-516
OBJECTIVESelenium is an essential trace element and has a main role in cellular antioxidant defense system. In very preterm babies, low selenium is associated with an increased risk of complications such as chronic neonatal lung disease and retinopathy of prematurity. This study was designed to determine and compare maternal and umbilical cord blood selenium levels in term and preterm infants.
METHODSFrom February 2008 to April 2008, 30 term (gestational age>37 weeks) and 30 preterm infants (gestational age<34 weeks) and their mothers were enrolled. Selenium concentrations in umbilical cord and maternal venous blood were measured by atomic absorption spectrometry.
RESULTSThe mean selenium concentration in term infants was higher than in preterm infants (124.80+/-13.72 microg/L vs 100.30+/-11.72 microg/L, P=0.0001). The mean selenium concentration in mothers of term and preterm infants was not significantly different (117.03+/-17.15 microg/L vs 110.56+/-17.49 microg/L, P=0.15). Cord selenium concentrations were strongly correlated with gestational age and birth weight (r=0.66, p<0.0001 and r=0.59, p<0.0001, respectively) when the data of all infants were analyzed together. None of the 60 women had a serum selenium level below the laboratory lower limit of normal (70.0 microg/L). Maternal selenium levels were correlated with cord selenium levels in their infants (r=0.40, p<0.001) when data of all newborn infants and mothers were considered together.
CONCLUSIONSMothers have a relatively good selenium status and serum selenium is not a significant predictor of preterm delivery in Isfahan. The cord selenium concentration in term infants is significantly higher than in preterm infants, but the cord selenium concentrations in both groups are in a suggested normal range.
Birth Weight ; Female ; Fetal Blood ; chemistry ; Gestational Age ; Humans ; Infant, Newborn ; Infant, Premature ; Male ; Pregnancy ; blood ; Selenium ; blood
5.Investigation and analysis of plasma trace elements of oldest elderly in longevity areas in China.
Jian-Wei XU ; Xiao-Ming SHI ; Zhao-Xue YIN ; Yu-Zhi LIU ; Yi ZHAI ; Yi ZENG
Chinese Journal of Preventive Medicine 2010;44(2):119-122
OBJECTIVETo investigate the levels and differences of plasma selenium, manganese, iron, copper, zinc among oldest elderly in longevity areas in China.
METHODS446 oldest elderly including 208 centenarians, 238 aged 90 and over, who lived in Xiayi county of Henan province (110 persons), Zhongxiang city of Hubei province (111 persons), Mayang county of Hunan province (60 persons), Sanshui district of Guangdong province (113 persons), Yongfu county of Guangxi Zhuang autonomous region (52 persons) in China, were selected. The contents of plasma selenium, manganese, iron, copper, zinc were detected and compared among these elderly who were classified into different genders, different regions and different age groups.
RESULTSIn oldest elderly, the median (inter-quartile range) of content of plasma selenium was 1.44 (0.91) micromol/L, content of manganese was 0.54 (0.94) micromol/L, content of iron was 69.17 (102.85) micromol/L, content of copper was 20.19 (8.73) micromol/L, content of zinc was 31.66 (32.51) micromol/L. Contents of plasma selenium of oldest elderly in Xiayi, Zhongxiang, Mayang, Sanshui, Yongfu region were 1.46 (0.66), 1.30 (0.80), 1.06 (0.51), 2.39 (1.53) and 1.35(0.55) micromol/L; contents of plasma manganese were 0.56 (0.51), 1.40 (1.11), 0.35 (0.71), 0.44 (0.55) and 0.15 (0.21) micromol/L; contents of plasma iron were 86.77 (86.87), 141.42 (101.83), 38.88 (36.28), 31.38 (46.19) and 79.64 (75.34) micromol/L; contents of plasma copper were 22.16 (8.11), 19.46 (9.26), 21.36 (12.38), 18.12 (6.74) and 21.47 (7.85) micromol/L; contents of plasma zinc were 36.85 (26.18), 36.59 (35.94), 39.98 (56.91), 25.05 (24.92) and 16.74 (16.81) micromol/L. Contents of plasma trace elements among oldest elderly in different longevity areas were significantly different (F values were 29.76, 38.75, 47.18, 11.51 and 13.47, P values were all less than 0.05). Contents of plasma trace elements in different gender groups (contents of plasma selenium were 1.38 (0.83) micromol/L in male and 1.45 (0.91) micromol/L in female; contents of plasma manganese were 0.52 (0.95) and 0.54 (0.91) micromol/L; contents of plasma iron were 69.23 (104.06) and 69.11 (101.05) micromol/L; contents of plasma copper were 20.28 (8.72) and 20.06 (8.76) micromol/L; contents of plasma zinc were 28.39 (32.58) and 31.85 (34.26) micromol/L) were not significantly different (t(Se) = -1.82, P = 0.07; t(Mn) = 0.64, P = 0.52; t(Fe) = 0.65, P = 0.52; t(Cu) = -1.90, P = 0.06; t(Zn) = -0.96, P = 0.34). The contents of plasma selenium, iron, copper in centenarians were higher than those aged 90 and over (contents of plasma selenium were 1.63 (0.94) micromol/L and 1.30 (0.82) micromol/L, contents of plasma iron were 112.63 (119.78) and 60.13 (58.43) micromol/L, contents of plasma copper were 21.07 (9.03) and 18.81 (8.86) micromol/L, F value were 41.99, 27.32, 24.45, P values were less than 0.01). Content of plasma manganese in centenarians was lower than those aged 90 and over (0.44 (0.76) and 0.64 (0.93) micromol/L, F = 10.76, P < 0.01). No significant differences were detected in plasma zinc between concentration and those aged 90 and over (31.78 (34.06) and 31.11 (33.85) micromol/L; F = 1.32, P = 0.25).
CONCLUSIONThe concentrations of plasma selenium, manganese, iron, copper and zinc were high in oldest elderly in the longevity areas. The contents of plasma selenium, iron, copper increased with age.
Aged, 80 and over ; China ; Copper ; blood ; Female ; Humans ; Iron ; blood ; Longevity ; Male ; Manganese ; blood ; Plasma ; chemistry ; Selenium ; blood ; Trace Elements ; blood ; Zinc ; blood
6.Magnesium, zinc, copper, manganese, and selenium levels in postmenopausal women with osteoporosis. Can magnesium play a key role in osteoporosis?
Ersin ODABASI ; Mustafa TURAN ; Ahmet AYDIN ; Cemal AKAY ; Mustafa KUTLU
Annals of the Academy of Medicine, Singapore 2008;37(7):564-567
INTRODUCTIONThere has been a resurgence of interest in studies concerning the role of elements in the development and maintenance of the skeleton. The aim of the study was to assess the plasma and red blood concentrations of some elements in postmenopausal women with osteoporosis.
MATERIALS AND METHODSSeventy-seven postmenopausal women with osteoporosis aged 61 years (median interquartile range, 7.5; range, 46 to 74) and 61 age- and BMI-matched healthy postmenopausal women aged 60 years (median interquartile range, 8.0; range, 44 to 76) were included in the study. Element concentrations in plasma and red blood cells including magnesium (Mg), zinc, copper, manganese, and selenium were measured by atomic absorption spectrophotometry in both postmenopausal women with osteoporosis and healthy postmenopausal women.
RESULTSOnly statistically significant difference between the osteoporotic (51.51 [15.40] microg/mL) and healthy subjects (54.54 [15.42] microg/mL) was observed in red blood cell (RBC) magnesium concentration (Z=-2.07, P=0.039). However, no significant difference was found between patient and control groups, both in plasma and in red blood concentrations, for zinc, copper, manganese, and selenium.
CONCLUSIONMg levels in red blood cells are significantly lower in postmenopausal women with osteoporosis. It is concluded that Mg transport mechanism(s) into the cell could be affected in patients with osteoporosis.
Aged ; Bone Density ; Case-Control Studies ; Copper ; blood ; Female ; Humans ; Magnesium ; blood ; Manganese ; blood ; Middle Aged ; Osteoporosis, Postmenopausal ; blood ; physiopathology ; Risk Factors ; Selenium ; blood ; Turkey ; Zinc ; blood
7.Effect of trace elements on retinopathy of prematurity.
Hong, YANG ; Yi, DING ; Ling, CHEN
Journal of Huazhong University of Science and Technology (Medical Sciences) 2007;27(5):590-2
The effect of the trace elements on retinopathy of prematurity (ROP) were studied. Thirty preterm infants who had potential high risk factors of ROP were selected as observation group and 18 normal infants as control groups. By using atom spectrophotometer, the contents of serum trace elements (Mg, Cu, Zn, Mn, Se) were measured and analyzed statistically. The contents of serum Zn, Cu and Se in observation group were 0.75+/-0.22, 0.41+/-0.20 and (134.07+/-71.57)x10(-3) mg/L respectively, and 0.55+/-0.12, 0.65+/-0.194 and (202.92+/-44.71)x10(-3) mg/L in control group respectively (P<0.01). The contents of Cu and Se were obviously lower and that of Zn higher in observation group than those in control group. The same results were obtained between the infants with ROP and controls (P<0.01). However, there was no significant difference in the contents of serum Mg and Mn between two groups (P>0.05). It was concluded that the contents of serum Cu and Se in preterm infants who had high risk factors of ROP were obviously lower than in the controls. The contents of serum Cu and Se in the ROP infants were also much lower while contents of Zn much higher. Attention should be paid to the detection of the trace elements in preterm infants in order to prevent the deficiencies of Cu and Se. Only in this way can we prevent the deficiencies of Cu and Se, so as to decrease the ROP risk factors and prevent the disease.
Copper/blood
;
Infant, Premature/*blood
;
Retinopathy of Prematurity/*blood
;
Retinopathy of Prematurity/*prevention & control
;
Risk Factors
;
Selenium/blood
;
Spectrophotometry, Atomic
;
Trace Elements/*blood
;
Zinc/blood
8.Circulating adhesion molecules in patients with Keshan disease and their relationship with Coxsackie B virus infection.
Congsheng, LI ; Xiaolin, NIU ; Cong, LEI
Journal of Huazhong University of Science and Technology (Medical Sciences) 2009;29(2):173-6
This study determined the levels of serum soluble intercellular adhesion molecule-1 (sICAM-1) and soluble vascular cell adhesion molecular-1 (sVCAM-1) in patients with different types of Keshan disease (KD), examined the relationship between Coxsackie B virus-specific IgM antibody (CBV-IgM) and sICAM-1 or sVCAM-1 in KD patients, and investigated the role of these adhesion molecules in the pathogenesis of KD and their clinical implications. The levels of serum sICAM-1, sVCAM-1 and CBV-IgM were measured by using enzyme-linked immunosorbent assay in 22 patients with chronic Keshan disease (CKD), 27 with latent Keshan disease (LKD) and 28 healthy controls. The subjects in different groups were adjusted for sex and age. Echocardiography was adopted to determine left ventricular ejection fraction (LVEF) in 22 patients with CKD. The results showed that CKD patients had significantly higher levels of sICAM-1 and sVCAM-1 than LKD patients and healthy controls (P<0.01 for all). And there was significant difference in the levels of the 2 adhesion molecules between LKD patients and healthy controls (P<0.05). A negative correlation was found between LVEF and sICAM-1 or sVCAM-1 in CKD patients. The percentage of CBV-specific IgM positive individuals in KD patients was significantly higher than that of healthy controls. In CVB-specific IgM positive patients, the levels of serum sICAM-1 and sVCAM-1 were significantly greater than those in CBV-specific IgM negative counterpart. It was concluded that the increase in the levels of sICAM-1 and sVCAM-1 suggests the progression of inflammation in KD. sICAM-1 and sVCAM-1 can promote the development of myocardial pathology and lead to poor myocardial function. The increased serum sICAM-1 and sVCAM-1 in KD patients may be related to CBV infection.
Cardiomyopathies/*blood
;
Cardiomyopathies/etiology
;
Cardiomyopathies/*virology
;
Coxsackievirus Infections/*complications
;
Enterovirus B, Human
;
Intercellular Adhesion Molecule-1/*blood
;
Selenium/blood
;
Vascular Cell Adhesion Molecule-1/blood
;
Young Adult
9.A nested case-control study on the association of neonatal cord blood selenium, iron and copper with congenital heart disease.
Qian LIU ; Bao Hong MAO ; Jian Hua LI ; Wen Di WANG ; Shi Hua DU ; Qing LIU ; Bin YI
Chinese Journal of Preventive Medicine 2023;57(2):200-207
Objective: To investigate the relationship between the levels of selenium, iron and copper in cord blood of neonates and the risk of congenital heart disease (CHD), and analyze their interaction effects. Methods: The subjects were obtained from the birth cohort in Lanzhou area established from 2010 to 2012. A baseline survey was conducted in the first trimester, and the follow-up was conducted in the second trimester, third trimester and 42 days after delivery. The umbilical vein blood was collected from newborns at delivery, and information on their birth outcomes was extracted from medical records. A nested case-control study was used to select 97 neonates with CHD newly diagnosed by echocardiography as the case group, and 194 neonates were selected as the control group by 1∶2 matching according to their mother's age, block and CHD onset time. Inductively coupled ion mass spectrometry was used to detect the concentrations of selenium, iron and copper in neonatal cord blood. The element exposure was categorized into three groups, the low, medium and high concentrations, according to the quartiles Q1 and Q3 of selenium, iron and copper concentrations in the control group. The association between cord blood selenium, iron and copper concentrations and CHD was analyzed by conditional logistic regression model using medium concentration as the reference standard. The association of their interactions with CHD was analyzed by a phase multiplication model. Results: The M (Q1, Q3) concentration of neonatal cord blood copper was 746.12 (467.48, 759.74) μg/L in the case group and 535.69 (425.21, 587.79) μg/L in the control group, with a statistically significant difference between the two groups (P<0.05). After adjustment for confounders, logistic regression models showed that the risk of CHD development was increased in neonates with either high copper in cord blood (OR=4.062, 95%CI: 2.013-8.199) or high copper combined with high iron (OR=3.226, 95%CI: 1.343-7.750). No correlation was observed between selenium and iron concentrations and the development of CHD in neonates. There was a multiplicative interaction between copper and iron in cord blood on the risk of developing CHD (OR=1.303, 95%CI: 1.056-1.608). Conclusion: There is a multiplicative interaction between iron and copper elements. The high copper and the high copper combined with high iron in umbilical cord blood are risk factors for neonatal CHD.
Humans
;
Infant, Newborn
;
Copper/analysis*
;
Selenium
;
Iron/analysis*
;
Fetal Blood/chemistry*
;
Case-Control Studies
;
Heart Defects, Congenital
10.Biochemical Markers of Oxidative Stress in Saudi Women with Recurrent Miscarriage.
Hazem K GHNEIM ; Mashael M ALSHEBLY
Journal of Korean Medical Science 2016;31(1):98-105
This study was undertaken to investigate the antioxidant/oxidant status in recurrent miscarriage patients. Antioxidants including glutathione peroxidase (GPx), catalase (CAT), glutathione reductase (GR), reduced glutathione (GSH) and selenium (Se), as well as the oxidants hydrogen peroxide (H2O2), oxidised glutathione (GSSG) and lipid peroxidation were assayed in plasma, whole blood and placental tissue of non-pregnant women (NP), healthy pregnant women (HP), and recurrent miscarriage (RM) patients. Results indicated that all antioxidant activities and levels in plasma and whole blood of HP women were consistently moderately lower, and much more significantly lower in RM patients when both were compared to those seen in NP women (P<0.05 and P<0.001, respectively). Furthermore, whereas plasma antioxidant activities and levels were significantly lower in RM patients, those of whole blood and placental tissue were much more significantly lower when compared with HP women (P<0.001). Concurrent with these findings there were consistent increases of equal statistical significance and magnitude in the levels of all investigated oxidants assayed in all samples when compared in between subjects of the study as indicated above. Data thus illustrated a distinct shift in favor of oxidative reactions and reactive oxygen species (ROS) generation, and very significant decreases in the GSH/GSSG ratios in whole blood and placental tissue of RM patients when compared to HP and NP women (P<0.001). The above noted oxidative stress could have been a major causative factor of recurrent miscarriage.
Abortion, Habitual/*blood/*epidemiology
;
Adult
;
Antioxidants/analysis
;
Biomarkers/*blood
;
Catalase/blood
;
Female
;
Glutathione/blood
;
Glutathione Peroxidase/blood
;
Glutathione Reductase/blood
;
Humans
;
Hydrogen Peroxide/analysis
;
Lipid Peroxidation
;
*Oxidative Stress
;
Placenta/metabolism
;
Pregnancy
;
Reactive Oxygen Species/metabolism
;
Saudi Arabia/epidemiology
;
Selenium/blood