1.Biocompatibility of root-end filling materials: recent update.
Payal SAXENA ; Saurabh Kumar GUPTA ; Vilas NEWASKAR
Restorative Dentistry & Endodontics 2013;38(3):119-127
The purpose of a root-end filling is to establish a seal between the root canal space and the periradicular tissues. As root-end filling materials come into contact with periradicular tissues, knowledge of the tissue response is crucial. Almost every available dental restorative material has been suggested as the root-end material of choice at a certain point in the past. This literature review on root-end filling materials will evaluate and comparatively analyse the biocompatibility and tissue response to these products, with primary focus on newly introduced materials.
Dental Pulp Cavity
2.Efficacy of Bacillus Calmette-Guérin in Cancer Prevention and Its Putative Mechanisms
Sakshi GUPTA ; Saurabh YADAV ; Pawan KUMAR
Journal of Cancer Prevention 2024;29(1):6-15
Bacillus Calmette-Guérin (BCG) is an attenuated strain of Mycobacterium bovis. Although it was developed as a prophylactic vaccine against tuberculosis (TB), researchers have also evaluated it for preventing cancer development or progression. These studies were inspired by the available data regarding the protective effects of microbial infection against cancers and an inverse relationship between TB and cancer mortality. Initial studies demonstrated the efficacy of BCG in preventing leukemia, melanoma and a few other cancers. However, mixed results were observed in later studies. Importantly, these studies have led to the successful use of BCG in the tertiary prevention of non-muscle invasive bladder cancer, wherein BCG therapy has been found to be more effective than chemotherapy. Moreover, in a recently published 60-year follow-up study, childhood BCG vaccination has been found to significantly prevent lung cancer development. In the present manuscript, we reviewed the studies evaluating the efficacy of BCG in cancer prevention and discussed its putative mechanisms. Also, we sought to explain the mixed results of BCG efficacy in preventing different cancers.
3.Interleukin-1B (IL-1B-31 and IL-1B-511) and interleukin-1 receptor antagonist (IL-1Ra) gene polymorphisms in primary immune thrombocytopenia.
Deependra Kumar YADAV ; Anil Kumar TRIPATHI ; Divya GUPTA ; Saurabh SHUKLA ; Aloukick Kumar SINGH ; Ashutosh KUMAR ; Jyotsna AGARWAL ; K N PRASAD
Blood Research 2017;52(4):264-269
BACKGROUND: Immune thrombocytopenia (ITP) is an immune-mediated disease caused by autoantibodies against platelets membrane glycoproteins GPIIb/IIIa and GPIb/IX. The etiology of ITP remains unclear. This study evaluated the association of polymorphisms in interleukin (IL)-1B-31, IL-1B-511, and IL-1Ra with ITP. METHODS: Genotyping of IL-1B-31, IL-1B-511, and IL-1Ra was performed in 118 ITP patients and 100 controls by polymerase chain reaction restriction fragment length polymorphism and detection of variable number tandem repeats. RESULTS: Genotype differences in IL-1B-31 and IL-1Ra were significantly associated with ITP. Patients showed a higher frequency of the IL-1B-31 variant allele (T) and a 1.52-fold greater risk of susceptibility to ITP (odds ratio [OR]=1.52, 95% confidence interval [CI]=1.04–2.22, P=0.034). The frequencies of both homozygous and heterozygous variant genotypes of IL-1B-31 were higher (OR=2.33, 95% CI=1.069–5.09, P=0.033 and OR=2.044, 95% CI=1.068–39, P=0.034) among patients and were significantly associated with ITP susceptibility. Both homozygous and heterozygous variant genotypes of IL-1Ra were also more frequent (OR=4.48, 95% CI=1.17–17.05, P=0.0230 and OR=1.80, 95% CI=1.03–3.14, P=0.0494) among patients and were associated with ITP risk. IL-1B-31 and IL-1Ra also showed significant association with severe ITP. However, IL-1B-511 was not associated with ITP. CONCLUSION: IL-1B-31 and IL-1Ra polymorphisms may significantly impact ITP risk, and they could be associated with disease severity, which may contribute to the pathogenesis of ITP.
Alleles
;
Autoantibodies
;
Genotype
;
Humans
;
Interleukin 1 Receptor Antagonist Protein
;
Interleukin-1*
;
Interleukins
;
Membrane Glycoproteins
;
Minisatellite Repeats
;
Polymerase Chain Reaction
;
Polymorphism, Restriction Fragment Length
;
Purpura, Thrombocytopenic, Idiopathic*
4.Prevalence of hepatitis B, hepatitis C and human immunodeficiency viral infections in patients with inflammatory bowel disease in north India.
Parnita HARSH ; Vipin GUPTA ; Saurabh KEDIA ; Sawan BOPANNA ; Sucharita PILLI ; SURENDERNATH ; Govind Kumar MAKHARIA ; Vineet AHUJA
Intestinal Research 2017;15(1):97-102
BACKGROUND/AIMS: Patients with inflammatory bowel disease (IBD) often require immunosuppressive therapy and blood transfusions and therefore are at a high risk of contracting infections due to hepatitis B (HBV) and hepatitis C (HCV) and human immunodeficiency virus (HIV). In the present study, we assessed the prevalence of these infections in patients with IBD. METHODS: This retrospective study included 908 consecutive patients with IBD (ulcerative colitis [UC], n=581; Crohn's disease [CD], n=327) who were receiving care at a tertiary care center. Ninety-five patients with intestinal tuberculosis (ITB) were recruited as disease controls. Prospectively maintained patient databases were reviewed for the prevalence of HBV surface antigen, anti-HCV antibodies, and HIV (enzyme-linked immunosorbent assay method). HCV RNA was examined in patients who tested positive for anti-HCV antibodies. Prevalence data of the study were compared with that of the general Indian population (HBV, 3.7%; HCV, 1%; HIV, 0.3%). RESULTS: The prevalence of HBV, HCV, and HIV was 2.4%, 1.4%, and 0.1%, respectively, in the 908 patients with IBD. Among the 581 patients with UC, 2.2% (12/541) had HBV, 1.7% (9/517) had HCV, and 0.2% (1/499) had HIV. Among the 327 patients with CD, 2.8% (8/288) had HBV, 0.7% (2/273) had HCV, and 0% (0/277) had HIV. One patient with CD had HBV and HCV coinfection. The prevalence of HBV, HCV, and HIV in patients with ITB was 5.9% (4/67), 1.8% (1/57), and 1.2% (1/84), respectively. CONCLUSIONS: The prevalence of HBV, HCV, and HIV in north Indian patients with IBD is similar to the prevalence of these viruses in the general community. Nonetheless, the high risk of flare after immunosuppressive therapy mandates routine screening of patients with IBD for viral markers.
Antigens, Surface
;
Biomarkers
;
Blood Transfusion
;
Coinfection
;
Colitis
;
Colitis, Ulcerative
;
Crohn Disease
;
Hepatitis B*
;
Hepatitis C Antibodies
;
Hepatitis C*
;
Hepatitis*
;
HIV
;
Humans*
;
India*
;
Inflammatory Bowel Diseases*
;
Mass Screening
;
Prevalence*
;
Prospective Studies
;
Retrospective Studies
;
RNA
;
Tertiary Care Centers
;
Tuberculosis
5.Herniation of malignant lung cavity.
Saurabh Kumar SINGH ; Rakesh BHARGAVA ; Zuber AHMAD ; Deepak K PANDEY ; Shirin NAAZ ; Vibhanshu GUPTA
Chinese Medical Journal 2008;121(17):1757-1758
Adenocarcinoma
;
complications
;
Female
;
Hernia
;
etiology
;
Humans
;
Lung Diseases
;
etiology
;
Lung Neoplasms
;
complications
;
Middle Aged
6.Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial
Saurabh GUPTA ; Abhay ELHENCE ; Sumit BANERJEE ; Sandeep YADAV ; Prabodh KANTIWAL ; Rajesh Kumar RAJNISH ; Pushpinder KHERA ; Rajesh MALHOTRA
Hip & Pelvis 2024;36(4):310-319
Purpose:
Fracture union after osteosynthesis of a fracture neck femur (FNF) occurs by compression of the fracture ends and potential neck shortening. Selection of an implant for fixation of a femoral fracture of the neck can be challenging when making management decisions. Femoral neck shortening after internal fixation of FNFs using a femoral neck system (FNS) or multiple cannulated cancellous screws (MCS) was compared.
Materials and Methods:
This prospective interventional single-blinded randomized controlled trial was conducted at a university teaching hospital. Sixty patients undergoing internal fixation for management of sub-capital or trans-cervical FNFs were randomized and assigned, to one of the two groups—the test group (FNS group) and the control group (MCS group). Primary outcome was determined by measuring the difference in 1-year shortening of the femoral neck on radiographs between FNS and MCS. The secondary objective was to determine the correlation between neck shortening with patient reported outcome measures (PROMs) at the end of the final follow-up.
Results:
At the final follow-up, shortening of the femoral neck was 3.77±1.87 mm in the FNS group, significantly lower compared with the MCS group, 6.53±1.59 mm.
Conclusion
Significantly less shortening of the femoral neck was observed in the FNS group compared with the MCS group. No statistically significant difference in PROMs was observed at 1-year follow-up. The findings of the study suggest that FNS can be regarded as a suitable alternative for internal fixation in young adults (<60 years) with trans-cervical and subcapital FNFs.
7.Retraction: Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial
Saurabh GUPTA ; Abhay ELHENCE ; Sumit BANERJEE ; Sandeep YADAV ; Prabodh KANTIWAL ; Rajesh Kumar RAJNISH ; Pushpinder KHERA ; Rajesh MALHOTRA
Hip & Pelvis 2025;37(1):85-85
8.Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial
Saurabh GUPTA ; Abhay ELHENCE ; Sumit BANERJEE ; Sandeep YADAV ; Prabodh KANTIWAL ; Rajesh Kumar RAJNISH ; Pushpinder KHERA ; Rajesh MALHOTRA
Hip & Pelvis 2024;36(4):310-319
Purpose:
Fracture union after osteosynthesis of a fracture neck femur (FNF) occurs by compression of the fracture ends and potential neck shortening. Selection of an implant for fixation of a femoral fracture of the neck can be challenging when making management decisions. Femoral neck shortening after internal fixation of FNFs using a femoral neck system (FNS) or multiple cannulated cancellous screws (MCS) was compared.
Materials and Methods:
This prospective interventional single-blinded randomized controlled trial was conducted at a university teaching hospital. Sixty patients undergoing internal fixation for management of sub-capital or trans-cervical FNFs were randomized and assigned, to one of the two groups—the test group (FNS group) and the control group (MCS group). Primary outcome was determined by measuring the difference in 1-year shortening of the femoral neck on radiographs between FNS and MCS. The secondary objective was to determine the correlation between neck shortening with patient reported outcome measures (PROMs) at the end of the final follow-up.
Results:
At the final follow-up, shortening of the femoral neck was 3.77±1.87 mm in the FNS group, significantly lower compared with the MCS group, 6.53±1.59 mm.
Conclusion
Significantly less shortening of the femoral neck was observed in the FNS group compared with the MCS group. No statistically significant difference in PROMs was observed at 1-year follow-up. The findings of the study suggest that FNS can be regarded as a suitable alternative for internal fixation in young adults (<60 years) with trans-cervical and subcapital FNFs.
9.Retraction: Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial
Saurabh GUPTA ; Abhay ELHENCE ; Sumit BANERJEE ; Sandeep YADAV ; Prabodh KANTIWAL ; Rajesh Kumar RAJNISH ; Pushpinder KHERA ; Rajesh MALHOTRA
Hip & Pelvis 2025;37(1):85-85
10.Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial
Saurabh GUPTA ; Abhay ELHENCE ; Sumit BANERJEE ; Sandeep YADAV ; Prabodh KANTIWAL ; Rajesh Kumar RAJNISH ; Pushpinder KHERA ; Rajesh MALHOTRA
Hip & Pelvis 2024;36(4):310-319
Purpose:
Fracture union after osteosynthesis of a fracture neck femur (FNF) occurs by compression of the fracture ends and potential neck shortening. Selection of an implant for fixation of a femoral fracture of the neck can be challenging when making management decisions. Femoral neck shortening after internal fixation of FNFs using a femoral neck system (FNS) or multiple cannulated cancellous screws (MCS) was compared.
Materials and Methods:
This prospective interventional single-blinded randomized controlled trial was conducted at a university teaching hospital. Sixty patients undergoing internal fixation for management of sub-capital or trans-cervical FNFs were randomized and assigned, to one of the two groups—the test group (FNS group) and the control group (MCS group). Primary outcome was determined by measuring the difference in 1-year shortening of the femoral neck on radiographs between FNS and MCS. The secondary objective was to determine the correlation between neck shortening with patient reported outcome measures (PROMs) at the end of the final follow-up.
Results:
At the final follow-up, shortening of the femoral neck was 3.77±1.87 mm in the FNS group, significantly lower compared with the MCS group, 6.53±1.59 mm.
Conclusion
Significantly less shortening of the femoral neck was observed in the FNS group compared with the MCS group. No statistically significant difference in PROMs was observed at 1-year follow-up. The findings of the study suggest that FNS can be regarded as a suitable alternative for internal fixation in young adults (<60 years) with trans-cervical and subcapital FNFs.