1.An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time.
Satoshi SHINOZAKI ; Yoshimasa MIURA ; Yuji INO ; Kenjiro SHINOZAKI ; Alan Kawarai LEFOR ; Hironori YAMAMOTO
Clinical Endoscopy 2015;48(6):516-521
BACKGROUND/AIMS: Poor suction ability through a narrow working channel prolongs esophagogastroduodenoscopy (EGD). The aim of this study was to evaluate suction with a new ultrathin endoscope (EG-580NW2; Fujifilm Corp.) having a 2.4-mm working channel in clinical practice. METHODS: To evaluate in vitro suction, 200 mL water was suctioned and the suction time was measured. The clinical data of 117 patients who underwent EGD were retrospectively reviewed on the basis of recorded video, and the suction time was measured by using a stopwatch. RESULTS: In vitro, the suction time with the EG-580NW2 endoscope was significantly shorter than that with the use of an ultrathin endoscope with a 2.0-mm working channel (EG-580NW; mean +/- standard deviation, 22.7+/-1.1 seconds vs. 34.7+/-2.2 seconds; p<0.001). We analyzed the total time and the suction time for routine EGD in 117 patients (50 in the EG-580NW2 group and 67 in the EG-580NW group). In the EG-580NW2 group, the total time for EGD was significantly shorter than that in the EG-580NW group (275.3+/-42.0 seconds vs. 300.6+/-46.5 seconds, p=0.003). In the EG-580NW2 group, the suction time was significantly shorter than that in the EG-580NW group (19.2+/-7.6 seconds vs. 38.0+/-15.9 seconds, p<0.001). CONCLUSIONS: An ultrathin endoscope with a 2.4-mm working channel considerably shortens the routine EGD time by shortening the suction time, in comparison with an endoscope with a 2.0-mm working channel.
Diagnosis
;
Early Detection of Cancer
;
Endoscopes*
;
Endoscopy, Digestive System*
;
Humans
;
Retrospective Studies
;
Suction*
;
Water
2.An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time.
Satoshi SHINOZAKI ; Yoshimasa MIURA ; Yuji INO ; Kenjiro SHINOZAKI ; Alan Kawarai LEFOR ; Hironori YAMAMOTO
Clinical Endoscopy 2016;49(1):100-100
The publisher wishes to apologize for the incorrectly inputted arrow in the figure.
3.Single-Stage Endoscopic Stone Extraction and Cholecystectomy during the Same Hospitalization
Toshiaki TERAUCHI ; Hiroharu SHINOZAKI ; Satoshi SHINOZAKI ; Yuichi SASAKURA ; Masaru KIMATA ; Junji FURUKAWA ; Alan Kawarai LEFOR ; Yoshiro OGATA ; Kenji KOBAYASHI
Clinical Endoscopy 2019;52(1):59-64
BACKGROUND/AIMS: The clinical impact of single-stage endoscopic stone extraction by endoscopic retrograde cholangiopancreatography (ERCP) and cholecystectomy during the same hospitalization remains elusive. This study aimed to determine the efficacy and safety of single-stage ERCP and cholecystectomy during the same hospitalization in patients with cholangitis. METHODS: We retrospectively reviewed the medical records of 166 patients who underwent ERCP for mild to moderate cholangitis due to choledocholithiasis secondary to cholecystolithiasis from 2012 to 2016. RESULTS: Complete stone extraction was accomplished in 92% of patients (152/166) at the first ERCP. Among 152 patients who underwent complete stone extraction, cholecystectomy was scheduled for 119 patients (78%). Cholecystectomy was performed during the same hospitalization in 89% of patients (106/119). We compared two groups of patients: those who underwent cholecystectomy during the same hospitalization (n=106) and those who underwent cholecystectomy during a subsequent hospitalization (n=13). In the delayed group, cholecystectomy was performed about three months after the first ERCP. There were no significant differences between the groups in terms of operative time, rate of postoperative complications, and interval from cholecystectomy to discharge. CONCLUSIONS: Single-stage endoscopic stone extraction is recommended in patients with mild to moderate acute cholangitis due to choledocholithiasis. The combination of endoscopic stone extraction and cholecystectomy during the same hospitalization is safe and feasible.
Cholangiopancreatography, Endoscopic Retrograde
;
Cholangitis
;
Cholecystectomy
;
Cholecystectomy, Laparoscopic
;
Cholecystolithiasis
;
Choledocholithiasis
;
Hospitalization
;
Humans
;
Medical Records
;
Operative Time
;
Patient Outcome Assessment
;
Postoperative Complications
;
Retrospective Studies
4.Roles of Capsule Endoscopy and Balloon-Assisted Enteroscopy in the Optimal Management of Small Bowel Bleeding
Hani ABUTALIB ; Tomonori YANO ; Satoshi SHINOZAKI ; Alan Kawarai LEFOR ; Hironori YAMAMOTO
Clinical Endoscopy 2020;53(4):402-409
The small bowel had long been considered a dark unapproachable tunnel until the invention of capsule endoscopy and doubleballoon enteroscopy in the 21st century, which revolutionized the diagnosis and management of small bowel diseases, including bleeding. Various imaging modalities such as computed tomographic enterography, angiography, capsule endoscopy, and balloonassisted enteroscopy play vital roles in the diagnosis and management of small bowel bleeding. The choice of modality to use and timing of application differ according to the availability of the modalities, patient’s history, and physician’s experience. Small bowel bleeding is managed using different strategies as exemplified by medical treatment, interventional radiology, endoscopic therapy, or surgical intervention. Balloon-assisted enteroscopy enables endoscopic interventions to control small bowel bleeding, including electrocautery, argon plasma coagulation, clip application, and tattooing as a prelude to surgery. In this article, we clarify the recent approaches to the optimal diagnosis and management of patients with small bowel bleeding.
5.Advanced Treatment and Imaging in Colonoscopy: The Pocket-Creation Method for Complete Resection and Linked Color Imaging for Better Detection of Early Neoplastic Lesions by Colonoscopy
Hironori YAMAMOTO ; Satoshi SHINOZAKI ; Yoshikazu HAYASHI ; Yoshimasa MIURA ; Tsevelnorov KHURELBAATAR ; Hiroyuki OSAWA ; Alan Kawarai LEFOR
Clinical Endoscopy 2019;52(2):107-113
Early detection and resection of neoplastic lesions are key objectives to diminish colorectal cancer mortality. Resection of superficial colorectal neoplasms, cold snare polypectomy, endoscopic mucosal resection, and endoscopic submucosal dissection have all been developed and used worldwide. The pocket-creation method facilitates the resection of tumors in difficult and routine locations. Early detection is the most important first step to maximize the benefits of recent advancements in endoscopic techniques. However, the detection of small, flat-shaped, or faded color lesions remains difficult. Linked color imaging, a novel multi-light technology, facilitates the recognition of minor differences in tissue by enhancing the color contrast between early colorectal neoplasms and surrounding normal mucosa in a bright field of view. The most striking feature of linked color imaging is its ability to display the color of early neoplastic lesions as distinct from inflammatory changes, both of which have similar “redness” when viewed using white light imaging. To increase the detection rate of neoplasms, linked color imaging should be used from the outset for endoscopic observation. Early detection of superficial colorectal tumors can result in decreased mortality from colorectal cancer and maintain a good quality of life for patients.
Colonoscopy
;
Colorectal Neoplasms
;
Endoscopy
;
Humans
;
Methods
;
Mortality
;
Mucous Membrane
;
Quality of Life
;
SNARE Proteins
;
Strikes, Employee
7.The accuracy and optimal slice thickness of multislice helical computed tomography for right and left ventricular volume measurement.
Wei CUI ; Takeshi KONDO ; Hirofumi ANNO ; Yu-yin GUO ; Takahisa SATO ; Masayoshi SARAI ; Hitoshi SHINOZAKI ; Satoshi KAKIZAWA ; Kouji SUGIURA ; Keita OSHIMA ; Kazuhiro KATADA ; Hitoshi HISHIDA
Chinese Medical Journal 2004;117(9):1283-1287
BACKGROUNDMultislice helical computed tomography (MSCT) has been used to depict coronary anatomy noninvasively, and proved useful for evaluating ventricular function. The aim of our study was to assess the accuracy of ventricular volume as measured by MSCT.
METHODSFourteen human left ventricular (LV) and 15 right ventricular (RV) casts were scanned by MSCT. A series of LV and RV short-axis images were reconstructed later with slice thickness of 2.0 mm, 3.5 mm, 5.0 mm, 7.0 mm, and 10.0 mm. Ventricular volume was calculated by the multislice tomographic Simpson's method. True LV and RV cast volumes were determined by water displacement.
RESULTSBoth calculated LV and RV volumes correlated highly with the corresponding true volumes (all r >0.95, P <0.01). But with slice thickness from 2.0 mm to 10.0 mm, MSCT scanning overestimated the corresponding true volume by (3.21 +/- 5.95) ml to (12.58 +/- 8.56) ml for LV and (10.22 +/- 8.45) ml to (23.91 +/- 12.24) ml for RV (all P <0.01). There was a very high correlation between the overestimation and the selected slice thickness for both LV and RV volume measurements (r=0.998 and 0.996, P <0.01, respectively). However, when slice thickness was reduced to 5.0 mm, the overestimation for both LV and RV volume measurements became nonsignificant for slice thickness from 2.0 mm to 5.0 mm.
CONCLUSIONSBoth LV and RV volumes can be accurately estimated by MSCT. Thinner slice has more accurate calculated volume. However, 5.0 mm slice thickness is thin enough for an accurate measurement of LV or RV volume.
Adolescent ; Adult ; Aged ; Cardiac Volume ; Child ; Child, Preschool ; Female ; Heart Ventricles ; Humans ; Magnetic Resonance Imaging ; Male ; Middle Aged ; Tomography, Spiral Computed ; methods