1.Value of serum miR-922 and miR-506 expression levels in the diagnosis and prognostic assessment of childhood acute lymphoblastic leukemia.
Yi-Yue ZHU ; Ri-Nuan WU ; Xia LI ; Xiang-Bi CHEN
Chinese Journal of Contemporary Pediatrics 2021;23(10):1021-1026
OBJECTIVES:
To study the value of serum miR-922 and miR-506 expression levels in the diagnosis and prognostic assessment of childhood acute lymphoblastic leukemia (ALL).
METHODS:
A total of 132 children with ALL (ALL group) and 80 healthy children (healthy control group) were prospectively selected in this study. Quantitative real-time polymerase chain reaction was used to measure the expression levels of serum miR-922 and miR-506 in both groups. Receiver operating characteristic (ROC) curves were plotted to analyze the diagnostic value of miR-922 and miR-506 for childhood ALL. The Kaplan-Meier method was used to plot survival curves, and multivariate COX regression models were used to analyze the risk factors for poor prognosis in children with ALL.
RESULTS:
The ALL group had significantly higher expression levels of serum miR-922 and miR-506 than the control group (
CONCLUSIONS
The expression levels of miR-922 and miR-506 are of good value in the diagnosis and prognostic assessment of childhood ALL.
Biomarkers, Tumor
;
Child
;
Humans
;
Kaplan-Meier Estimate
;
MicroRNAs/genetics*
;
Precursor Cell Lymphoblastic Leukemia-Lymphoma/genetics*
;
Prognosis
;
ROC Curve
2.Evaluation of the Normal Structures of Parotid Duct Using Magnetic Resonance Hydrography.
Yue FU ; Yi Si HUA ; Qi Meng LIU ; Ye Zhi CHEN
Acta Academiae Medicinae Sinicae 2019;41(6):818-820
To investigate the normal structures of parotid duct by using magnetic resonance(MR)hydrography. MR three-dimensional heavy T2-weighted imaging was performed in 21 normal subjects.After taking 200 mg of vitamin C orally for 3 minutes,the subjects underwent parotid duct coronal hydro-magnetic resonance imaging.The images were transferred to the GE AW4.5 workstation,on which multi-planner reformation was performed using Functool software.The numbers of the parotid duct,accessory parotid duct,segments,and its branches was counted and the length and diameter of the intra-and extra-parotid ducts were measured. Accessory ducts were found in 24 parotid glands(57.1%,24/42),with the average length being(9.54±9.98)mm and the average diameter being(0.87±0.88)mm.The intra-parotid ducts were found to be with 3 segments were in 3 cases(7.14%,3/42),with 2 segments in 19 cases(45.23%,19/42),and with 1 segment in 20 cases(47.62%,20/42).The average number of the branches of the first,second and third segment was 2.38,0.88,and 0.1,respectively.The average length of the intra-parotid duct was(36.97±7.97)mm,with its average diameter being(2.01±0.76)mm.The average length of extra-parotid duct was(34.98±10.25)mm,with its average diameter being(2.13±0.79)mm.The average length of the whole parotid duct was(71.95±11.47)mm,with its average diameter being(2.07±0.68)mm. The parotid duct,the accessory parotid duct,and the segments and their branches of the intra-parotid duct can be accurately displayed by MR hydrography.
Magnetic Resonance Imaging
;
Magnetic Resonance Spectroscopy
;
Parotid Gland
3.Expression and Clinical Significance of Serum MiR-424 and MiR-765 in Multiple Myeloma.
Juan-Juan HUANG ; Fen ZHUO ; Yue-Hong CAI ; Hua XIAO
Journal of Experimental Hematology 2022;30(2):461-465
OBJECTIVE:
To investigate the expression and clinical significance of miR-424 and miR-765 in patients with multiple myeloma (MM).
METHODS:
The eighty-one MM patients admitted to Sanya Central Hospital from January 2017 to July 2020 were divided into phase Ⅰ (n=16), phase Ⅱ (n=25) and phase Ⅲ (n=40) according to the international staging system, while they were divided into IgG type (n=46), IgA type (n=19), light chain type (n=10) and non secretory type (n=6) according to the results of immunotyping. Another 50 healthy normal persons in the same period were selected as the control group. The levels of serum miR-424, miR-765 and Cystatin C (Cys-C) were measured in each group. The diagnostic value of serum miR-424, miR-765 and Cys-C in MM was estimated by ROC curve. Pearson correlation was used to analyze the correlation between serum levels of miR-424, miR-765 and Cys-C in MM patients.
RESULTS:
The serum levels of miR-424 (2.74±1.30 vs 0.85±0.26), miR-765 (2.05±0.82 vs 0.63±0.17) and Cys-C [(2.18±0.86 vs 0.72±0.15) mg/L] in MM group were significantly higher than those in control group (P<0.001). The serum levels of miR-424 (5.08±2.36 vs 1.12±0.34, 2.24±0.93), miR-765 (3.50±1.52 vs 0.74±0.20, 1.78±0.65) and Cys-C [(3.81±1.30 vs 0.92±0.24, 1.68±0.55) mg/L] in MM patients at stage Ⅲ were significantly higher than those in patients at stage Ⅰ and Ⅱ (P<0.001). Also the serum levels of the three molecules in phase II were significantly higher than those in phase I (P<0.001). The serum levels of miR-424 and miR-765 in MM patients at IgG type were significantly higher than those at IgA, light chain and non secretory types (P<0.001). ROC curve analysis showed that the area under the curve (0.952,95%CI: 0.890-0.993) was greatest for the combination of miR-424, miR-765 and Cys-C for diagnosis of MM, and its sensitivity and specificity were 95.0% and 87.2%. The results of correlation analysis showed that the serum levels of miR-424 and miR-765 were positively correlated with Cys-C (r=0.795,r=0.760).
CONCLUSION
The serum levels of miR-424 and miR-765 in MM patients are significantly increased in the pattern increasing with the progression of MM stage. Combined with Cys-C, miR-424 and miR-765 have high value in the diagnosis of MM.
Humans
;
Immunoglobulin A
;
Immunoglobulin G
;
MicroRNAs
;
Multiple Myeloma
;
ROC Curve
4.Research progress on immune system function damage induced by microwave radiation
Sanya YUE ; Rong WANG ; Yuhua WANG ; Jing LI ; Mengjuan SHANG
Journal of Environmental and Occupational Medicine 2024;41(8):954-960
With the rapid advancement and wide application of microwave technology, it enhances convenience while potentially endangering health. The immune system, as a vital shield, is an important protective barrier and also one of the sensitive targets of microwave radiation. The immune system is particularly affected by microwave radiation via innate and adaptive immune responses, which is supported by both population surveys and experimental studies; however, the precise mechanism of immunotoxicity of microwave radiation remains under investigation. In light of recent scientific advances in the correlation between microwave radiation and the immune system, the deleterious impact of microwave radiation on innate immunity was delineated. Microwave radiation can induce irregular innate immune function by damaging macrophages, neutrophils, natural killer cells, and dendritic cells. The effects of microwave radiation on adaptive immunity were also elucidated. Microwave radiation can impair cellular immune response by influencing T cell proliferation, maturation and activation, and distribution of T cell subpopulation, and also hinder humoral immune function by influencing B lymphocyte protein expression, maturation during development, and number of B cells. Disparity in the immune function of the body can precipitate the onset of various immune-associated diseases, so the immunotoxic effects of microwave radiation and associated protection need considerable attention and detailed investigation. This article reviewed the shortcomings of existing studies, and suggested that future experimental studies should use experimental parameters that are more similar to the actual scene of life and work, pay more attention to the biological effects of combined multi-frequency microwave exposure on the immune system, use standardized and unified experimental methods, and incorporate more sophisticated experimental technologies to further elucidate the laws of damage effect and exact mechanism of microwave radiation on the immune system, so as to provide a scientific basis for potent protection against the damage effect of microwave radiation on the immune system.
5.Anti-A/B Antibody Titers in Group O Healthy Donors in Hainan Province Area.
Shuai YU ; Yong-Wen HUANG ; Xiao-Xi WANG ; Yue-Qing WU ; Meng-Xia LIN ; Yang YU ; Qun LUO
Journal of Experimental Hematology 2015;23(4):1138-1143
OBJECTIVETo detect the IgM anti-A (B) and IgG anti-A (B) antibody titers of group O healthy donors in Hainan province area, to understand the distribution of O-type blood donor IgM and IgG antibody titers and to analyze the relationship between antibody titers, so as to provide experimental evidences for the safety and feasibility of urgent transfusion of uncrossmatched group O RBCs.
METHODSGroup O whole blood sample was collected from 80 volunteers blood donors. IgM antibody titrations was performed using the immediate spin (IS) tube, and IgG antibody titration were performed using the column agglutination technique with anti-human globulin (AHG). Using two-way ANOVA, paired t-test and correlation analysis, the different types of antibodies were compared.
RESULTSThe IgM antibody titers distributed in 4-1 024, IgG antibody titer distributed in 2-2 048. Anti-A antibody titers of IgG were significantly higher than that of IgM anti-B, IgG anti-B and IgM anti-A titers (P < 0.05). There was a positive correlation bewteen IgM anti-A and anti-B, IgM anti-B and IgG anti-B, IgG anti-A and anti-B (P < 0.05).
CONCLUSIONGroup O blood donors have high antibody titers in Hainan province area, type O RBC suspensions should be first screened through screening the anti-A titer of IgG, so that can significantly improve the pass rate of O-type universal blood and reduce testing costs.
ABO Blood-Group System ; immunology ; Antibodies ; Blood Donors ; Blood Transfusion ; China ; Erythrocytes ; Humans
6.Advances in research on microwave radiation-induced reproductive system damage and its treatment
Rong WANG ; Sanya YUE ; Jing LI ; Mengjuan SHANG
Chinese Journal of Radiological Medicine and Protection 2024;44(7):633-640
Microwave technology has been widely applied in various fields such as military affairs, communication, transportation, medical treatment, and industrial and agricultural production. Nevertheless, such technology poses potential threats to human health while bringing convenience to production and life. Previous studies have shown that the reproductive system is one of the most sensitive targets to microwave radiation, and its microwave damage effect and treatment have garnered wide concern. This paper reviews the recent domestic and foreign studies on the impacts of microwave radiation on reproductive health and its treatment, especially the damage effects, mechanisms, and treatment method, from the aspects of epidemiological investigations and animal experiments. The purpose is to provide suggestions and references for future research on the effects of microwave radiation on reproductive damage and its treatment.