1.Lung Nodule Detection on Chest CT: Evaluation of a Computer-Aided Detection (CAD) System.
In Jae LEE ; Gordon GAMSU ; Julianna CZUM ; Ning WU ; Rebecca JOHNSON ; Sanjay CHAKRAPANI
Korean Journal of Radiology 2005;6(2):89-93
OBJECTIVE: To evaluate the capacity of a computer-aided detection (CAD) system to detect lung nodules in clinical chest CT. MATERIALS AND METHODS: A total of 210 consecutive clinical chest CT scans and their reports were reviewed by two chest radiologists and 70 were selected (33 without nodules and 37 with 1-6 nodules, 4-15.4 mm in diameter). The CAD system (ImageChecker (R) CT LN-1000) developed by R2 Technology, Inc. (Sunnyvale, CA) was used. Its algorithm was designed to detect nodules with a diameter of 4-20 mm. The two chest radiologists working with the CAD system detected a total of 78 nodules. These 78 nodules form the database for this study. Four independent observers interpreted the studies with and without the CAD system. RESULTS: The detection rates of the four independent observers without CAD were 81% (63/78), 85% (66/78), 83% (65/78), and 83% (65/78), respectively. With CAD their rates were 87% (68/78), 85% (66/78), 86% (67/78), and 85% (66/78), respectively. The differences between these two sets of detection rates did not reach statistical significance. In addition, CAD detected eight nodules that were not mentioned in the original clinical radiology reports. The CAD system produced 1.56 false-positive nodules per CT study. The four test observers had 0, 0.1, 0.17, and 0.26 false-positive results per study without CAD and 0.07, 0.2, 0.23, and 0.39 with CAD, respectively. CONCLUSION: The CAD system can assist radiologists in detecting pulmonary nodules in chest CT, but with a potential increase in their false positive rates. Technological improvements to the system could increase the sensitivity and specificity for the detection of pulmonary nodules and reduce these false-positive results.
*Diagnosis, Computer-Assisted
;
False Positive Reactions
;
Humans
;
Lung Diseases/*radiography
;
Lung Neoplasms/radiography
;
Radiography, Thoracic/*methods
;
Sensitivity and Specificity
;
Tomography, X-Ray Computed/*methods
2.Evaluation of postoperative pain in patients undergoing modified radical mastectomy with pectoralis or serratus-intercostal fascial plane blocks
Ushkiran KAUR ; Chetna SHAMSHERY ; Anil AGARWAL ; Neel PRAKASH ; Ramya Chakrapani VALIVERU ; Prabhaker MISHRA
Korean Journal of Anesthesiology 2020;73(5):425-433
Background:
Regional nerve blocks are an integral part of multimodal analgesia and should be chosen based on their efficacy, convenience, and minimal side effects. Here, we compare the use of pectoral (PEC II) and serratus-intercostal fascial plane (SIFP) blocks in breast carcinoma cases undergoing modified radical mastectomy (MRM) in terms of the postoperative analgesic efficacy and shoulder mobility.
Methods:
The primary outcome of this prospective controlled study was to compare the postoperative static and dynamic pain scores, and the secondary outcome was to assess the shoulder pain, range of shoulder joint motion, and hemodynamic parameters. Sixty patients were randomly allocated to three groups and given general anesthesia. All patients received paracetamol, diclofenac, and rescue doses of tramadol based on the Institute's Acute Pain Service (APS) policy. No block was performed in group C (control), whereas groups P and S received PEC II and SIFP blocks, respectively, before surgical incision.
Results:
The groups were comparable in terms of age, weight, height, and body mass index distribution (P > 0.05). Dynamic pain relief was significantly better 12 and 24 h postoperatively in groups P (P = 0.034 and P = 0.04, respectively) and S (P = 0.01 and P = 0.02, respectively) compared to group C. Shoulder pain relief and shoulder mobility were better in group S, while the hemodynamic parameters were more stable in group P.
Conclusions
Both SIFP and PEC blocks have comparable dynamic and static pain relief with better shoulder pain scores in patients receiving SIFP.