1.A study for the development of Korean version of the Duke-UNC functional social support questionnaire.
Sang Yeon SUH ; Young Sin IM ; So Hyeon LEE ; Min Sun PARK ; Taiwoo YOO
Journal of the Korean Academy of Family Medicine 1997;18(3):250-260
BACKGROUND: Social support is defined as interpersonal transaction ; the giving of symbolic or material aid to another. It has been shown to have both buffering effects and direct beneficial effects on diverse health related outcomes. But there has been the dearth of well-validated measurement instruments. This article describes the development of Korean version of the Duke-UNC functional social support questionnaire(DUFSS), focusing on the aspect of social support. METHODS: The 13-item, self-administered questionnaire was translated to Korean language. It was evaluated on 177 patients attending the family medicine clinic of Seoul National University Hospital during one month(November, 1996.) Comparisons to the family APGAR, COOP/ WONCA functional status chart are made to assess validity. Factor analyses are performed. Correlation of the questionnire score with the sum of family APGAR and each items of COOP/ WONCA functional chart are measured Internal consistency are evaluated. RESULTS: The questionnaire score are correlated with significantly correlated with social activity item. The total Cronbachs alpha is calculated as 0.89. The four content areas developed by factor analyses are donfidant support(items 8, 9, 10), af fective support(items 4, 5, 6, 7), instrumental support(items 3, 12) and quantity of support(item 1). These shows similarity to American study results. CONCLUSIONS: The Korean version of the Duke-UNC functional social support questionnaire has been documented as having high reliability and moderate validity. It covers two dimensions well(confidant support, affective support) with a small enough number of questions. Instrumental support may need further study.
Humans
;
Seoul
;
Surveys and Questionnaires
2.A Study the Procurement of HLA Class I Typing Trays Using Gushed Out Blood During Placental Delivery.
So Yong KWON ; Kang Sung EUN ; Kyung Sin PARK ; Yoo Sung HWANG ; Sang In KIM
Journal of the Korean Society for Microbiology 1999;34(1):53-60
BACKGROUND: Microlymphocytotoxicity test is most widely used for HLA Class l typing but almost all laboratories depend on imported HLA Class 1 typing trays. Matching criteria for the selection of HLA- matched platelets to treat platelet refractoriness is not as strict as for bone marrow transplantation. Therefore, with the acquisition of various antisera against high frequency HLA antigens, self-made HLA typing trays can be used for HLA typing of HLA-matched platelet donors. METHODS: 140 samples obtained during placental delivery were tested for the presence of HLA antibodies against a well-characterized panel of 90 cells. Specificity of HLA antisera were determined by evaluating the correlation coefficient r of the 2 x 2 table, x2 test. Antisera strength was evaluated by the strength index. RESULTS: HLA antibodies were detected in 25 samples by primary screening and 23 samples also showed a positive reaction in secondary screening(16%). Among 23 samples, 1 1 antisera were of reagent grade quality and 7 were monospecific antisera. DISCUSSION: Imported HLA typing trays can be replaced by harvesting HLA antisera against HLA antigens which are relatively common in Koreans through continuous HLA antibody screening using gushed out blood during placental delivery. (Korean J Blood Transfusion 10(1): 53-60, 1999)
Antibodies
;
Blood Platelets
;
Blood Transfusion
;
Bone Marrow Transplantation
;
Histocompatibility Testing
;
HLA Antigens
;
Humans
;
Immune Sera
;
Mass Screening
;
Sensitivity and Specificity
;
Tissue Donors
3.Clinical Study fo Pulmonary Thromboembolism.
Sang Myeon BAK ; Sang Hwa LEE ; Sin Hyung LEE ; Cheol SIN ; Jae Youn CHO ; Jae Jeong SHIM ; Kwang Ho IN ; Kyung Ho KANG ; Se Hwa YOO
Tuberculosis and Respiratory Diseases 2001;50(1):106-116
BACKGROUND: Pulmonary thromboembolism is relatively frequent and potentially fatal. However, it is commonly misdiagnosed. The incidence of pulmonary thromboembolism is not decreasing despite advances in diagnosis and effective prophylatic measures. Its potential for significant sequela necessitates a prompt diagnosis and treatment. Unfortunately, there are many difficulties and problems regarding accurate diagnosis. There is a low prevalence of deep vein thrombosis and pulmonary thromboembolism in Korea and only few reports on this subject are available. METHOD: The clinical features of 36 patients, who were diagnosed with pulmonary thromboembolism at the Korea University medical center, were reviewed. RESULTS: 1) There was no significant difference in prevalence between men an women, and the mean age was 50.9 years in men 59.2 years in women. 2) The frequent causes of pulmonary thromboembolism were malignancies (22.2%), surgery (22.2%), and heart disease(8.2%). Specific causes were not identified in 33.3%. 3) The most common symptom was dyspnea(72.2%), and the most common sign was tachypnea(61.1%). 4) The EKG findings were normal in 28.6%, and S1Q3T3 pulmonale pattern in 25.7%, ST or QRS changes in others. 5) The chest X-ray findings indicated pulmonary infiltation in 37.5%, cardiomegaly in 15.6%, pleural effusion in 12.5%, and normal in 27.8%. The perfusion lung scan showed a high probability in 66.7%, and intermediate or low probability in 33.3%. 6) The pulmonary arterial pressure(PAP) in the high probability groups was 57.9mmHg with a higher mortality rate(35%). CONCLUSION: Pulmonary thromboembolism is not uncommon in Korea and its clinical features do not differ greatly from those reported in the literature. When pulmonary thromboemblism of unknown causes are diagnosed, a search for an occult malignancy is recommended. Rapid diagnosis and treatment are achieved when thromboemblism is suspected.
Academic Medical Centers
;
Cardiomegaly
;
Diagnosis
;
Electrocardiography
;
Female
;
Heart
;
Humans
;
Incidence
;
Korea
;
Lung
;
Male
;
Mortality
;
Perfusion
;
Pleural Effusion
;
Prevalence
;
Pulmonary Embolism*
;
Thorax
;
Tomography, Spiral Computed
;
Venous Thrombosis
4.Etiology of Pediatric Healthcare-associated Infections in a Single Center (2007-2011).
Ki Wook YUN ; Mi Kyung LEE ; Sin Weon YUN ; Soo Ahn CHAE ; In Seok LIM ; Eung Sang CHOI ; Byoung Hoon YOO
Korean Journal of Nosocomial Infection Control 2012;17(1):13-20
BACKGROUND: Healthcare-associated infections (HAIs) are among the most important threats to patient safety. When hospitalized children face these threats, there is morbidity, mortality, prolonged hospitalization, and increased healthcare costs. Research on local healthcare epidemiology is necessary to enhance collective knowledge and evidence formanaging this problem. METHODS: We performed a retrospective analysis of databases of patients who were diagnosed with HAIs at Chung-Ang University Hospital (CAUH) from 2007 through 2011. Cases were selected from the microbiology registry databases. The data on prevalence of HAIs in various wards and its annual trends were compared to previously reported nationwide data. Moreover, we analyzed the patterns of antibiotic susceptibility results for HAI pathogens. RESULTS: A total of 181 HAIs were identified in 122 patients. The HAI rate among pediatric patients at CAUH was 2.4/1,000 person-hospital days. Urinary tract infections (UTIs) (53 episodes, 29.3%) were the most common, followed by pneumonia (33 episodes, 18.2%). Staphylococcus aureus was found to be the most common gram-positive organism, whereas Escherichia coli was the most common gram-negative organism. Methicillin-resistant S. aureus (MRSA) comprised 84% of the S. aureus infections. Imipenem resistance was detected in 58.8% and 55.0% of Acinetobacter baumannii and Pseudomonas aeruginosa isolates, respectively. CONCLUSION: Between 2007 and 2011, UTIs were the most common type of HAIs, and MRSA was the most common pediatric HAI pathogen, both in the general ward and intensive care unit at the CAUH. Further research on the epidemiology and pathogenesis of HAIs is necessary and prevention measures should be implemented to prevent HAIs in children.
Acinetobacter baumannii
;
Child
;
Child, Hospitalized
;
Delivery of Health Care
;
Escherichia coli
;
Health Care Costs
;
Hospitalization
;
Humans
;
Imipenem
;
Intensive Care Units
;
Methicillin Resistance
;
Methicillin-Resistant Staphylococcus aureus
;
Microbial Sensitivity Tests
;
Patient Safety
;
Patients' Rooms
;
Pneumonia
;
Prevalence
;
Pseudomonas aeruginosa
;
Retrospective Studies
;
Staphylococcus aureus
;
Urinary Tract Infections
5.Modelling of Elastic Blood Vessel under the Pulsatile Flow.
Sang Ho SUH ; Hyung Woon ROH ; Sang Sin YOO ; Dong Ik KIM ; Byung Boong LEE
Journal of the Korean Society for Vascular Surgery 1999;15(2):213-217
PURPOSE: Characteristics of pulsatile flow in 3-dimensional arterial geometry and elastic vessel wall should be investigated in order to understand the physiological blood flow in human body. In this study, the modelling of the physiological blood flow in the elastic blood vessel is proposed. METHODS: The finite volume predictions are used to analyse the pulsatile flow characteristics in the elastic blood vessel. RESULTS AND CONCLUSION: Variations of the pressure and the velocity waveforms are obtained using the proposed modelling. The magnitudes of the pressure waveforms in the elastic blood vessel model are bigger than those of the rigid blood vessel model.
Blood Vessels*
;
Human Body
;
Pulsatile Flow*
6.Visualization of Pulsatile Flow of the Blood Substitute Fluids Using the Particle Image Velocimetry.
Sang Ho SUH ; Hyung Woon ROH ; Sang Sin YOO ; Dong Ik KIM ; Byung Boong LEE
Journal of the Korean Society for Vascular Surgery 1999;15(2):205-212
PURPOSE: The objective of the present study is to investigate the steady and pulsatile flow phenomena of the blood substitute fluids in the circular and bifurcated vessels numerically and experimentally. METHODS: The particle image velocimetry (PIV) is adopted to visualize the flow fields in the circular and bifurcated vessels. In order to analyse the complex flow phenomena of the blood substitute fluids in the bifurcated vessel, the constitutive equations which are suitable to describe the rheological properties of the non-Newtonian fluids are determined and the steady and unsteady momentum equations are solved by the finite volume prediction. RESULTS AND CONCLUSION: Velocity vectors of the steady flow in the bifurcated tube obtained by the PIV system are in good agreement with those obtained by the numerical analysis. The experimental and numerical results show the recirculation zone in the outer wall distal to bifurcation.
Blood Substitutes*
;
Pulsatile Flow*
;
Rheology*
7.Analysis of Hemodynamic Characteristics in Anastomotic Sites of Femoral Artery Implantation.
Sang Ho SUH ; Hyung Woon ROH ; Sang Sin YOO ; Dong Ik KIM ; Byung Boong LEE
Journal of the Korean Society for Vascular Surgery 1999;15(1):35-44
The objective of the present study is to obtain information on the hemodynamic characteristics in the anastomotic sites of femoral artery through the vascular implantation. Three dimensional steady and physiological blood flows in the femoral artery are simulated using the finite volume method. The geometrical shape of the anastomotic sites is made based on the vascular anatomy of a white rabbit. Wall shear stress distributions in the anastomotic sites for the physiological flow are compared with those for steady flow. Blood flow phenomena in the anastomotic sites of the femoral artery are discussed extensively.
Arteries
;
Femoral Artery*
;
Hemodynamics*
8.Analysis of Hemodynamic Characteristics in End-to-Side Anastomoses with Miller Cuff.
Sang Ho SUH ; Hyung Woon ROH ; Sang Sin YOO ; Dong Ik KIM ; Byung Boong LEE
Journal of the Korean Society for Vascular Surgery 1999;15(1):29-34
The hemodynamic characteristics of the cuff end-to-side anastomosis model are investigated using by the finite volume predictions. The flow rates and the impedance indices through of the cuff anastomosis model are compared with those of the anastomosis model without the cuff. Blood flow increased through the cuff anastomosis model than the standard anastomosis model. The impedance index decreased with the increase of flow rate. The impedance index at a given flow rate is reduced by the increase of anastomosis angle and further reduced by the addition of the cuff. The results suggest that the cuff anastomosis model should be applied for the low Reynolds number flow and/or the small artery anastomosis model.
Arteries
;
Electric Impedance
;
Hemodynamics*
9.Fundamental Study for Simulation of Blood Cell Motion in a Blood Vessel.
Sang Ho SUH ; Hyeong Jong KIM ; Sang Sin YOO ; Dong Ik KIM ; Byung Boong LEE ; Sun Joung LEE
Journal of the Korean Society for Vascular Surgery 2000;16(1):9-17
PURPOSE: The objective of this study is to investigate the blood cell motion in human capillary by applying the boundary singularity method. METHODS: A particle motion of spherical shape falling in a vertical tube filled with Newtonian fluid is studied by using the boundary singularity method and the experiment. RESULTS AND CONCLUSION: As the eccentric ratio increases up to 0.6, the rotational velocity increases almost linearly and the falling velocity remains constant. However, as the eccentric ratio exceeds 0.6, the rotational velocity increases rapidly and the falling velocity decreases. As the tube radius increases, falling velocity increases and approaches the stokes velocity and the rotational velocity decreases.
Blood Cells*
;
Blood Vessels*
;
Capillaries
;
Humans
;
Radius
10.Fundamental Study for Simulation of Blood Cell Motion in a Blood Vessel.
Sang Ho SUH ; Hyeong Jong KIM ; Sang Sin YOO ; Dong Ik KIM ; Byung Boong LEE ; Sun Joung LEE
Journal of the Korean Society for Vascular Surgery 2000;16(1):9-17
PURPOSE: The objective of this study is to investigate the blood cell motion in human capillary by applying the boundary singularity method. METHODS: A particle motion of spherical shape falling in a vertical tube filled with Newtonian fluid is studied by using the boundary singularity method and the experiment. RESULTS AND CONCLUSION: As the eccentric ratio increases up to 0.6, the rotational velocity increases almost linearly and the falling velocity remains constant. However, as the eccentric ratio exceeds 0.6, the rotational velocity increases rapidly and the falling velocity decreases. As the tube radius increases, falling velocity increases and approaches the stokes velocity and the rotational velocity decreases.
Blood Cells*
;
Blood Vessels*
;
Capillaries
;
Humans
;
Radius