1.Angiographic Follow-up after Intracoronary Stenting with Flexible Coil(Gianturco-Roubin) Stent.
Won Heum SHIM ; Jong Won HA ; Sang Wook LIM ; June KWAN ; Moon Hyoung LEE
Korean Circulation Journal 1996;26(1):29-34
BACKGROUND: Intracoronary stent with various designs have been developed to treat dissections or acute closure after angioplasty. The efficacy of flexible coil stent as a bail-out device has been reported. However, the restenosis after stenting still remained as a main limitation like other devices. This study reports on the angiographic follow-up after successful intracoronary stenting with flexible coil stent. METHOD: From April 1993 through July 1994, coronary stenting was tried in 21 patients by a single operator for various indications(acute or threatened closure, suboptimal result after balloon angioplasty). The nineteen(95%) out of 20 patients in whom stent was successfully deployed underwent follow-up coronary angiography 7.6+/-3.0 months after coronary stenting. RESULT: Mean age was 54.7+/-11.3(33-73) years and 16 parients were men. Clinical diagnosis of patients were as follows : stable angina 7, unstable angina 6, old myocardial infarction with stable angina 6 and acute myocardial infarction in 1 patient, respectively. Stents were implanted at left anterior descending artery in 9, left circumflex artery in 5 and right coronary artery in 8. Ten out of 21 stents(47.6%) were found to be renarrowed more than 50% at follow-up coronary angiography. There was no significant difference in clinical and angiographic variables between restenosis group and no-restenosis group. Coronary artery bypass graft surgery was performed in 1 patient for the treatment of restenosis after stenting. Repeat PTCA was performed in 3 patients and remaining 5 patients were followed medically. CONCLUSION: Flexible coil(Gianturco-Roubin) coronary stent is a useful adjunct percutaneous intervention to prevent or minimize complicatioms associated with dissections. Despite favorable initial angiographic and clinical results, 47.6% of stents were found to be renarrowed significantly at follow-up coronary angiography. New techniques or more optimal characters of stents would be desired.
Angina, Stable
;
Angina, Unstable
;
Angioplasty
;
Arteries
;
Coronary Angiography
;
Coronary Artery Bypass
;
Coronary Vessels
;
Diagnosis
;
Follow-Up Studies*
;
Humans
;
Male
;
Myocardial Infarction
;
Stents*
;
Transplants
2.Angiographic Follow-up after Intracoronary Stenting with Flexible Coil(Gianturco-Roubin) Stent.
Won Heum SHIM ; Jong Won HA ; Sang Wook LIM ; June KWAN ; Moon Hyoung LEE
Korean Circulation Journal 1996;26(1):29-34
BACKGROUND: Intracoronary stent with various designs have been developed to treat dissections or acute closure after angioplasty. The efficacy of flexible coil stent as a bail-out device has been reported. However, the restenosis after stenting still remained as a main limitation like other devices. This study reports on the angiographic follow-up after successful intracoronary stenting with flexible coil stent. METHOD: From April 1993 through July 1994, coronary stenting was tried in 21 patients by a single operator for various indications(acute or threatened closure, suboptimal result after balloon angioplasty). The nineteen(95%) out of 20 patients in whom stent was successfully deployed underwent follow-up coronary angiography 7.6+/-3.0 months after coronary stenting. RESULT: Mean age was 54.7+/-11.3(33-73) years and 16 parients were men. Clinical diagnosis of patients were as follows : stable angina 7, unstable angina 6, old myocardial infarction with stable angina 6 and acute myocardial infarction in 1 patient, respectively. Stents were implanted at left anterior descending artery in 9, left circumflex artery in 5 and right coronary artery in 8. Ten out of 21 stents(47.6%) were found to be renarrowed more than 50% at follow-up coronary angiography. There was no significant difference in clinical and angiographic variables between restenosis group and no-restenosis group. Coronary artery bypass graft surgery was performed in 1 patient for the treatment of restenosis after stenting. Repeat PTCA was performed in 3 patients and remaining 5 patients were followed medically. CONCLUSION: Flexible coil(Gianturco-Roubin) coronary stent is a useful adjunct percutaneous intervention to prevent or minimize complicatioms associated with dissections. Despite favorable initial angiographic and clinical results, 47.6% of stents were found to be renarrowed significantly at follow-up coronary angiography. New techniques or more optimal characters of stents would be desired.
Angina, Stable
;
Angina, Unstable
;
Angioplasty
;
Arteries
;
Coronary Angiography
;
Coronary Artery Bypass
;
Coronary Vessels
;
Diagnosis
;
Follow-Up Studies*
;
Humans
;
Male
;
Myocardial Infarction
;
Stents*
;
Transplants
3.Hypotensive Efficacy and Safety of Manidipine on the Patient with Essential Hypertension.
Won Sang YOO ; Young Bin JEON ; Sang Hyun PARK ; Chang Young LIM ; Suck Koo CHOI
Korean Circulation Journal 1991;21(2):350-355
Thirty patient with essential hypertension were administered Manidipine, a new calcium antagonist, 10~20mg once daily to evaluate the hypotensive efficacy and safety for 8 weeks. And the followings were the result. 1) Patients were consists of 14 male, 16 female, aged 53 in average and classified as mild in 21 and moderate in 9 patients. 2) Optimum intial dose was 10mg and 10 to 20mg were the doses recommended. 3) Blood pressure dropped after 8 weeks 24/13mmHg in average, rewarding 80% effectiveness and normalized in 87%. 4) Most frequent side reaction was facial flushing in 5 patiens followed by palpitation and dizziness, all of which did not disturb the continuation of medication. 5) Most of routine laboratory parameter were normal and unchanged between before and after the trial. 6) Overall rating of usefulness was 77%. In conclusion, Manidipine 10 to 20mg once daily regimen is well tolerated and effective in the treatment of mild to moderate essential hypertension.
Blood Pressure
;
Calcium
;
Dizziness
;
Female
;
Flushing
;
Humans
;
Hypertension*
;
Male
;
Reward
4.Evaluation of rep-PCR Genomic Fingerprinting for the Molecular Systematics Study of Yersinia Species.
Young Chan LIM ; Ki Jeong KIM ; Mi Ok SONG ; Chul Min PARK ; Jung Ae LIM ; Won Young KIM ; Sang In CHUNG
Journal of Bacteriology and Virology 2002;32(4):367-380
No abstract available.
Classification*
;
Dermatoglyphics*
;
Yersinia*
5.Histologic evaluation and removal torque analysis of nano- and microtreated titanium implants in the dogs.
Seok AHN ; Mong Sook VANG ; Hong So YANG ; Sang Won PARK ; Hyun Pil LIM
The Journal of Advanced Prosthodontics 2009;1(2):75-84
STATEMENT OF PROBLEM: A number of studies about the nano-treated surfaces of implants have been conducting along with micro-treated surfaces of implants. PURPOSE: The purpose of this study was to get information for the clinical use of nano-treated surfaces compared with micro-treated surfaces by measuring removal torque and analyzing histological characteristics after the placement of various surface-treated implants on femurs of dogs. MATERIAL AND METHODS: Machined surface implants were used as a control group. 4 nano-treated surface implants and 3 micro-treated surface implants [resorbable blast media surface (RBM), sandblast and acid-etched surface (SAE), anodized RBM surface] were used as experimental groups. Removal torque values of implants were measured respectively and the histological analyses were conducted on both 4weeks and 8weeks after implant surgery. The surfaces of removed implants after measuring removal torque values were observed by scanning electron microscopy (SEM) at 8 weeks. RESULTS: 1. Removal torque values of the nano-treated groups were lower than those of micro-treated groups. 2. Removal torque values were similar in the anodized RBM surface groups. 3. On the histological views, there was much of bone formation at 8 weeks, but there was no difference between 4 and 8 weeks, and between the types of implant surfaces as well. CONCLUSION: It is suggested that implant topography is more effective in removal torque test than surface chemistry. To get better clinical result, further studies should be fulfilled on the combined effect of surface topography and chemistry for the implant surface treatments.
Animals
;
Dogs
;
Femur
;
Microscopy, Electron, Scanning
;
Osteogenesis
;
Titanium
;
Torque
6.A case of thanatophoric dwarfism.
Jae Young LIM ; Sang Won HAN ; Dae Hyun KIM ; Young Nyun PARK
Korean Journal of Obstetrics and Gynecology 1991;34(3):425-431
No abstract available.
Thanatophoric Dysplasia*
7.A Case of Lamellar Ichthyosis.
Yeon Seung LIM ; Sang Joo HAN ; Won Il PARK ; Kyung Ja LEE
Journal of the Korean Pediatric Society 1990;33(7):1018-1023
No abstract available.
Ichthyosis, Lamellar*
8.A STUDY ON THE BOND STRENGTH OF REINFORCED INDIRECT COMPOSITE RESINS TO DENTAL ALLOYS.
Dong Joo YOON ; Sang Wan SHIN ; yu Won SUH ; Ho Nam LIM
The Journal of Korean Academy of Prosthodontics 1999;37(5):620-639
Indirect composite resin are used as an popular effective esthetic material in prosthetic dentistry, often with metallic substructure that provides support for restorations. Recently, new indirect composite resins as a substitute of ceramic have been developed. These resins provide good esthetics, with a wide range of hue and chroma. And the flexural strength of those is in the range of 120-150MPa, which is higher than that of feldspathic ceramic, and similar tot hat of Dicor. Although it has many merits, one of the major clinical problems of composite resins is the bond failure between metal and resin due to insufficient interfacial bond strength. The purpose of this study was to evaluate shear bond strength of the reinforced indirect composite resin to dental alloys. Three different composite resin systems(Artglass . Sculpture , Targis ) as test groups and ceramic(VMK 68 ) as control group were bonded to Ni-Cr-Be alloy(Rexillium III ) and gold alloy(Dave 4). All specimens were stored at 37degrees C distilled water for 24 hours and the half of specimens were thermocycled 2000 times at temperature from 5degrees C to 60degrees C. The shear bond strengths of reinforced indirect composite resins to dental alloys were measured by using the universal testing machine, and modes of debonding were observed by stereoscope and scanning electron microscope. The results were as follows : 1. The shear bond strengths of reinforced indirect composit resins to dental alloys were approximately half those of ceramic to dental alloys(P<0.01). 2. There was no significant difference between the shear bond strength of several reinforced indirect composite resins to metal. 3. Alloy type did not affect on the shear bond strengths of resin to metal, but the shear bond strengths of ceramic to gold alloys were higher than those of ceramic to Ni-Cr alloys(P<0.05). 4. The shear bond strenghts of Artglass and Targis to gold alloys were significantly decreased after thermocycling treatment(P<0.01). 5. Sculpture showed cohesive, adhesive, and mixed failure modes, but Artglass and Targis showed adhesive or mixed failures. And ceramic showed cohesive and mixed failures.
Adhesives
;
Alloys
;
Ceramics
;
Composite Resins*
;
Dental Alloys*
;
Dentistry
;
Esthetics
;
Gold Alloys
;
Sculpture
;
Water
9.The Role of the Cytokines (IL-12, IFN-gamma) in the Generalized Shwartzman Reaction Induced by Vibrio Vulnificus Cytolysin.
Seok Don PARK ; Dong Lim KIM ; Sang Won LEE ; Jae Hoon CHUN ; Seung Hoon CHA
Korean Journal of Dermatology 2000;38(5):622-628
No Abstract Available.
Cytokines*
;
Perforin*
;
Shwartzman Phenomenon*
;
Vibrio vulnificus*
;
Vibrio*
10.Clinical study of intussusception in infants and childhood.
Sang Joo HAN ; Yeon Sung LIM ; Bae Young KIM ; Won Il PARK ; Kung Ja LEE
Journal of the Korean Pediatric Society 1989;32(11):1489-1495
No abstract available.
Humans
;
Infant*
;
Intussusception*