1.Angiographic Follow-up after Intracoronary Stenting with Flexible Coil(Gianturco-Roubin) Stent.
Won Heum SHIM ; Jong Won HA ; Sang Wook LIM ; June KWAN ; Moon Hyoung LEE
Korean Circulation Journal 1996;26(1):29-34
BACKGROUND: Intracoronary stent with various designs have been developed to treat dissections or acute closure after angioplasty. The efficacy of flexible coil stent as a bail-out device has been reported. However, the restenosis after stenting still remained as a main limitation like other devices. This study reports on the angiographic follow-up after successful intracoronary stenting with flexible coil stent. METHOD: From April 1993 through July 1994, coronary stenting was tried in 21 patients by a single operator for various indications(acute or threatened closure, suboptimal result after balloon angioplasty). The nineteen(95%) out of 20 patients in whom stent was successfully deployed underwent follow-up coronary angiography 7.6+/-3.0 months after coronary stenting. RESULT: Mean age was 54.7+/-11.3(33-73) years and 16 parients were men. Clinical diagnosis of patients were as follows : stable angina 7, unstable angina 6, old myocardial infarction with stable angina 6 and acute myocardial infarction in 1 patient, respectively. Stents were implanted at left anterior descending artery in 9, left circumflex artery in 5 and right coronary artery in 8. Ten out of 21 stents(47.6%) were found to be renarrowed more than 50% at follow-up coronary angiography. There was no significant difference in clinical and angiographic variables between restenosis group and no-restenosis group. Coronary artery bypass graft surgery was performed in 1 patient for the treatment of restenosis after stenting. Repeat PTCA was performed in 3 patients and remaining 5 patients were followed medically. CONCLUSION: Flexible coil(Gianturco-Roubin) coronary stent is a useful adjunct percutaneous intervention to prevent or minimize complicatioms associated with dissections. Despite favorable initial angiographic and clinical results, 47.6% of stents were found to be renarrowed significantly at follow-up coronary angiography. New techniques or more optimal characters of stents would be desired.
Angina, Stable
;
Angina, Unstable
;
Angioplasty
;
Arteries
;
Coronary Angiography
;
Coronary Artery Bypass
;
Coronary Vessels
;
Diagnosis
;
Follow-Up Studies*
;
Humans
;
Male
;
Myocardial Infarction
;
Stents*
;
Transplants
2.Angiographic Follow-up after Intracoronary Stenting with Flexible Coil(Gianturco-Roubin) Stent.
Won Heum SHIM ; Jong Won HA ; Sang Wook LIM ; June KWAN ; Moon Hyoung LEE
Korean Circulation Journal 1996;26(1):29-34
BACKGROUND: Intracoronary stent with various designs have been developed to treat dissections or acute closure after angioplasty. The efficacy of flexible coil stent as a bail-out device has been reported. However, the restenosis after stenting still remained as a main limitation like other devices. This study reports on the angiographic follow-up after successful intracoronary stenting with flexible coil stent. METHOD: From April 1993 through July 1994, coronary stenting was tried in 21 patients by a single operator for various indications(acute or threatened closure, suboptimal result after balloon angioplasty). The nineteen(95%) out of 20 patients in whom stent was successfully deployed underwent follow-up coronary angiography 7.6+/-3.0 months after coronary stenting. RESULT: Mean age was 54.7+/-11.3(33-73) years and 16 parients were men. Clinical diagnosis of patients were as follows : stable angina 7, unstable angina 6, old myocardial infarction with stable angina 6 and acute myocardial infarction in 1 patient, respectively. Stents were implanted at left anterior descending artery in 9, left circumflex artery in 5 and right coronary artery in 8. Ten out of 21 stents(47.6%) were found to be renarrowed more than 50% at follow-up coronary angiography. There was no significant difference in clinical and angiographic variables between restenosis group and no-restenosis group. Coronary artery bypass graft surgery was performed in 1 patient for the treatment of restenosis after stenting. Repeat PTCA was performed in 3 patients and remaining 5 patients were followed medically. CONCLUSION: Flexible coil(Gianturco-Roubin) coronary stent is a useful adjunct percutaneous intervention to prevent or minimize complicatioms associated with dissections. Despite favorable initial angiographic and clinical results, 47.6% of stents were found to be renarrowed significantly at follow-up coronary angiography. New techniques or more optimal characters of stents would be desired.
Angina, Stable
;
Angina, Unstable
;
Angioplasty
;
Arteries
;
Coronary Angiography
;
Coronary Artery Bypass
;
Coronary Vessels
;
Diagnosis
;
Follow-Up Studies*
;
Humans
;
Male
;
Myocardial Infarction
;
Stents*
;
Transplants
3.Hypotensive Efficacy and Safety of Manidipine on the Patient with Essential Hypertension.
Won Sang YOO ; Young Bin JEON ; Sang Hyun PARK ; Chang Young LIM ; Suck Koo CHOI
Korean Circulation Journal 1991;21(2):350-355
Thirty patient with essential hypertension were administered Manidipine, a new calcium antagonist, 10~20mg once daily to evaluate the hypotensive efficacy and safety for 8 weeks. And the followings were the result. 1) Patients were consists of 14 male, 16 female, aged 53 in average and classified as mild in 21 and moderate in 9 patients. 2) Optimum intial dose was 10mg and 10 to 20mg were the doses recommended. 3) Blood pressure dropped after 8 weeks 24/13mmHg in average, rewarding 80% effectiveness and normalized in 87%. 4) Most frequent side reaction was facial flushing in 5 patiens followed by palpitation and dizziness, all of which did not disturb the continuation of medication. 5) Most of routine laboratory parameter were normal and unchanged between before and after the trial. 6) Overall rating of usefulness was 77%. In conclusion, Manidipine 10 to 20mg once daily regimen is well tolerated and effective in the treatment of mild to moderate essential hypertension.
Blood Pressure
;
Calcium
;
Dizziness
;
Female
;
Flushing
;
Humans
;
Hypertension*
;
Male
;
Reward
4.Evaluation of rep-PCR Genomic Fingerprinting for the Molecular Systematics Study of Yersinia Species.
Young Chan LIM ; Ki Jeong KIM ; Mi Ok SONG ; Chul Min PARK ; Jung Ae LIM ; Won Young KIM ; Sang In CHUNG
Journal of Bacteriology and Virology 2002;32(4):367-380
No abstract available.
Classification*
;
Dermatoglyphics*
;
Yersinia*
5.The Role of the Cytokines (IL-12, IFN-gamma) in the Generalized Shwartzman Reaction Induced by Vibrio Vulnificus Cytolysin.
Seok Don PARK ; Dong Lim KIM ; Sang Won LEE ; Jae Hoon CHUN ; Seung Hoon CHA
Korean Journal of Dermatology 2000;38(5):622-628
No Abstract Available.
Cytokines*
;
Perforin*
;
Shwartzman Phenomenon*
;
Vibrio vulnificus*
;
Vibrio*
6.A MEASUREMENT OF DISPLACEMENTS OF CAST FRAMEWORK BY TORCH SOLDERING AND ELECTRIC SOLDERING TECHNIQUES.
Sang Won JEON ; Jang Seop LIM ; Chang Mo JEONG ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 1999;37(6):791-799
The purpose of this study was to investigate the displacements of cast framework by torch soldering and electric soldering techniques. Specimen had two cylinders and connecting bar that had sectioned with 0.3mm gap at mid point. 10 of total specimens were divided into two groups. In torch soldered group, soldering investment block was made and conventional torch soldering procedure was carried out. In electric soldered group, electric soldering was carried out on the master cast without soldering investment block by using electric soldering machine(Dentapunkt DP 7, Kulzer, Germany). After soldering procedure, three dimensional coordinates of two centroids of each cylinder were measured by three dimensional coordinate measuring machine. The intercentroidal displacement and global displacement were calculated and then, these values were compared and evaluated. The results were obtained as follows: 1. Intercentroidal distances of specimens decreased after both soldering procedures, and the decrease in intercentroidal distance was greater for torch soldered group than for electric soldered group 2. Global displacements of torch soldered group were greater than those of electric soldered group
Investments
7.Bacteriolysis and variation on the O-side chain lengths of lipopolysaccharides of salmonella typhi Ty21a with respective to the concentrations of galactose.
Jong Bae KIM ; Won Yong LEE ; Sang Hee PARK ; Min Kyung LIM ; Jin Yuen CHANG
Journal of the Korean Society for Microbiology 1992;27(5):419-425
No abstract available.
Bacteriolysis*
;
Galactose*
;
Lipopolysaccharides*
;
Salmonella typhi*
;
Salmonella*
8.A COMPARATIVE STUDY ON THE FRACTURE STRENGTH AND MARGINAL FITNESS OF FIBER-REINFORCED COMPOSITE BRIDGE.
Ho Kuen CHOI ; Sang wan SHIN ; Ho Nam LIM ; Kuyu Won SUH
The Journal of Korean Academy of Prosthodontics 2001;39(5):526-546
Fiber-reinforced composite(FRC) was developed as a structural component for dental appliances such as prosthodontic framework. FRC provides the potential for fabrication of a metal-free, excellent esthetic prostheses. It has demonstrated success as a result of its simple fabrication, natural colour, and marginal integrity, and fracture resistance of veneering composite resin and the FRC material. Although it has lots of merits, clinical and objective data are insufficient. The purpose of this study was to evaluate the fracture strength and marginal fitness of fiber-reinforced composite bridge in the posterior region for clinical application. Sixteen bridges of each group, Targis/Vectris(R), Sculpture-fibrekor(R)and In-Ceram, were fabricated. All specimens were cemented with Panavia 21 to the master dies. Strength evaluation was accomplished by a universal testing machine (Instron). The marginal fitness was measured by using the stereoscope (X50). The results were as follows. : 1.The fracture strength according to the materials was significantly decreaed in order In-Ceram(238.81+/-82). Targis Vectris(176.25+/-18.93), Sculpture-Fibrekor(120.35 +/-20.08) bridges. 2.FRC resin bridges were not completely fractured, while In-Ceram bridges were completely fractured in the pontic joint. 3.The marginal accuracy was significantly decreased in order Targis/Vectris (60.71micrometer), Sculpture-Fibrekor(73.10micrometer). In-Cream Bridge(83.81micrometer). 4.The fitness of occlusal sites had a lower value than the marginal sites(P<0.001), and the marginal gaps of inner site of the pontic were greater than that of outer sites of the pontic. Fiber reinforced composite bridges are new, esthetic prosthesis and can be clinically used in anterior regions and short span bridges. However, caution must be exercised when extrapolating laboratory data to the clinical situation because there are no long term clinical data regarding the overall success of the FRC.
Denture, Partial, Fixed
;
Joints
;
Prostheses and Implants
;
Prosthodontics
9.Clinical analysis of diagnostic method in obscure origin of gastrointestinal bleeding.
Jong Soo LEE ; Suk Won LIM ; Kyung Sup SONG ; Eung Kook KIM ; Sang Yong CHOO
Journal of the Korean Surgical Society 1992;42(2):267-274
No abstract available.
Hemorrhage*
10.Clinical analysis of diagnostic method in obscure origin of gastrointestinal bleeding.
Jong Soo LEE ; Suk Won LIM ; Kyung Sup SONG ; Eung Kook KIM ; Sang Yong CHOO
Journal of the Korean Surgical Society 1992;42(2):267-274
No abstract available.
Hemorrhage*