1.Does subepineural injection damage the nerve integrity?A technical report from four amputated limbs
Sandeep DIWAN ; Abhijit NAIR ; Parag SANCHETI ; André Van ZUNDERT
The Korean Journal of Pain 2021;34(1):132-136
Local anesthetic (LA) injection outside the sheath in epineural or paraneural connective tissue is considered safe practice among regional anesthesiologists. There is limited evidence as to whether neurological complications occur if LA is injected inside the sheath (subepineural - intraneural). We performed ultrasound guided injections at the level of undivided sciatic nerve in four amputated lower limbs. In two specimens, LA was injected in epineural connective tissue (paraneural tissue) and in another two specimens by penetrating the outer nerve sheath (hyperechoic epineurium). Ultrasonography demonstrated an increase in the size of nerve and macroscopic findings revealed fascicular tracings with sub-epineural injections. Limbs were sent for histological analysis in formalin containers. Pathologist performed the analysis which demonstrated an intact perineurium and a breach in the epineurium. We conclude that sub-epineural injections are unsafe and injection should be done in paraneural tissue to ensure safety and avoid unwanted neurological sequelae after the block.
2.Does subepineural injection damage the nerve integrity?A technical report from four amputated limbs
Sandeep DIWAN ; Abhijit NAIR ; Parag SANCHETI ; André Van ZUNDERT
The Korean Journal of Pain 2021;34(1):132-136
Local anesthetic (LA) injection outside the sheath in epineural or paraneural connective tissue is considered safe practice among regional anesthesiologists. There is limited evidence as to whether neurological complications occur if LA is injected inside the sheath (subepineural - intraneural). We performed ultrasound guided injections at the level of undivided sciatic nerve in four amputated lower limbs. In two specimens, LA was injected in epineural connective tissue (paraneural tissue) and in another two specimens by penetrating the outer nerve sheath (hyperechoic epineurium). Ultrasonography demonstrated an increase in the size of nerve and macroscopic findings revealed fascicular tracings with sub-epineural injections. Limbs were sent for histological analysis in formalin containers. Pathologist performed the analysis which demonstrated an intact perineurium and a breach in the epineurium. We conclude that sub-epineural injections are unsafe and injection should be done in paraneural tissue to ensure safety and avoid unwanted neurological sequelae after the block.
3.The Majority of Corona Mortis Are Small Calibre Venous Blood Vessels: A Cadaveric Study of North Indians
Sandeep KASHYAP ; Yogesh DIWAN ; Shweta MAHAJAN ; Deepa DIWAN ; Mukand LAL ; Randhir CHAUHAN
Hip & Pelvis 2019;31(1):40-47
PURPOSE: Corona mortis is an abnormal arterial or venous anastomosis between the external iliac and the obturator system of vessels and may cause significant hemorrhage during pelvi-acetabular fracture surgeries, hernia repair and laparoscopic gynecological procedures. Previous studies have estimated a prevalence of corona mortis between 34% and 70%. This cadaveric study was conducted to estimate the prevalence of corona mortis in the North Indian population. MATERIALS AND METHODS: Twelve cadavers (24 hemipelvises; 11 males and 1 female) with a mean age of 68 (range, 54–82) years were included in this study. RESULTS: Corona mortis was observed in 14 hemipelvises (58.3%). A total of 19 (79.2%) vascular anastomoses of diameter greater than 1 mm were observed; 5 hemipelvises (20.8%) had corona mortis on the right side, 9 hemipelvises (37.5%) on the left side and bilateral in 5 (41.7%) cases. Two hemipelvises (8.3%) had an arterial connection. An aberrant obturator artery was observed in 1 (4.2%) hemipelvis. A venous connection was found in 14 specimens (58.3% of hemipelvises). The average distance of the connecting vein from the symphysis pubis was 41 (35–70) mm. A vessel diameter of greater than 4 mm was observed in 4/24 (16.7%) of hemipelvises. CONCLUSION: The frequency of venous corona mortis was higher than arterial corona mortis and the majority (83.3%) were small calibre ( < 4 mm). The presentation pattern and the number of arterial or venous anastomoses were different in the majority of hemipelvises and dissimilar in both hemipelvises of the same cadaver in the majority of cases.
Acetabulum
;
Arteries
;
Blood Vessels
;
Cadaver
;
Hemorrhage
;
Herniorrhaphy
;
Humans
;
Male
;
Prevalence
;
Pubic Bone
;
Veins
4.Subcoracoid tunnel block as an alternative infraclavicular brachial plexus approach -a case series-
Sandeep DIWAN ; Divya SETHI ; Avinash GAIKWAD ; Parag SANCHETI ; Abhijit NAIR
Korean Journal of Anesthesiology 2020;73(5):450-454
Background:
Magnetic resonance neurography shows the brachial plexus cords in the subcoracoid tunnel beneath the pectoralis minor. With an ultrasound scan along the brachial line, the brachial plexus cords in the subcoracoid tunnel can be targeted using an in-plane needle approach. We describe this new approach to the infraclavicular block called the “subcoracoid tunnel block.”Case: Twenty patients were administered with the ultrasound-guided subcoracoid tunnel block for the below-elbow surgery. The contact of the needle tip with cords was visible in all 20 patients. With neurostimulation, the posterior cord was identified in 11 (55%) and medial cord in 9 (45%) patients on the first needle pass. The subcoracoid tunnel block was successful in 16 patients (80%).
Conclusions
Our case series shows that the subcoracoid tunnel block is an excellent alternative technique for the infraclavicular block. Its advantages include better needle-cord visibility and easy identification of the brachial plexus cords.