1.The benefit of radical prostatectomy in patients with lymph node-positive prostate cancer: a systematic review and Meta-analysis
Xu HU ; Weixiao YANG ; Weichao DOU ; Yanxiang SHAO ; Sanchao XIONG ; Jianbang LIU ; Xiang LI
Chinese Journal of Urology 2019;40(8):625-629
Objective To evaluate the benefit of radical prostatectomy (RP) in patients with lymph node-positive prostate cancer.Methods A systematic review of the studies about radical prostatectomy for the prognosis of node-positive prostate cancer was performed.An electronic search was completed on the basis of PubMed,Embase,Cochrane library,China Biology Medicine disc (CBM),China National Knowledge Infrastructure (CNKI),VIP and Wanfang database from inception up to November 2018.The outcomes are overall survival (OS) and cancer-specific survival (CSS).Results Six studies incorporating 7 890 patients were eligible for the present meta-analysis.6 247 patients underwent RP,the remaining 1 643 patients did not undergo RP.Lymph node-positive patients treated with RP had improved OS (HR =0.55,95% CI 0.49-0.62,P <0.001) and CSS (HR =0.49,95% CI 0.42-0.57,P < 0.001).Conclusions Radical prostatectomy may be a beneficial option for patients with lymph node metastases at initial diagnosis,which also improve the OS and CSS.More randomized controlled trials are needed to give more evidence further.
2.Comparison of the prognosis of subgroup of renal cell carcinoma of different pathological types
Yanxiang SHAO ; Weichao DOU ; Xu HU ; Shangqing REN ; Zhen YANG ; Thongher LIA ; Jianbang LIU ; Sanchao XIONG ; Weixiao YANG ; Qiang WEI ; Hao ZENG ; Xiang LI
Chinese Journal of Urology 2021;42(2):89-96
Objective:To study and compare the prognosis of different pathological subtypes of renal cell carcinoma (RCC).Methods:Clinicopathological and prognostic data of 1 346 cases of postoperative renal cell carcinoma during July 2002 to June 2014 in West China Hospital were collected retrospectively.There were 839 males and 507 females, aged (55.1±13.4)years, including 1 120 cases of clear cell RCC, 62 cases of papillary RCC, 79 cases of chromophobe RCC and 85 cases of the other pathological types respectively. ECOG 0 and ≥1 were 911 and 435 cases, with; T 1, T 2, T 3 and T 4 of 1 019, 177, 102 and 48 cases respectively; WHO nuclear grade for well, intermediate, poor differentiation and unknown were 587, 530, 85 and 144 cases separately.Tumor size <5cm, 5-10cm, ≥10cm and unknown were 685, 541, 104 and 16 cases.Combined with necrosis or sacromatoid differentiation were 200/1 146 and 27/1 319 cases separately. Meanwhile, data of 80 439 cases from Surveillance, Epidemiology, and End Results Program (SEER) were also collected.There were 51 371 males and 29 068 females, aged (60.9±12.4) years; , with 66 261, 8 680, 5 022 and 476 cases of White, Black, Asian, American native, or unknown race separately. There were 62 600 of clear cell RCC, 12 170 of papillary RCC, 4 354 of chromophobe RCC and 1 315 of other pathological types, with T 1, T 2, T 3 and T 4 of 55 332, 8 687, 15 516 and 904 cases respectively; WHO nuclear grade for well, intermediate and poor differentiation were 52 323, 22 700 and 5 416 cases separately.Tumor size <5cm, 5-10cm, ≥10cm were 46 741, 25 760 and 7 938 cases respectively. Kaplan-Meier survival analysis were performed on these two group of cases, with different factors between subgroups (gender, age, pathological types, tumor stage, size and nuclear grade) evaluated by log-rank test. To evaluate accuracy of outcome prediction models of SSIGN, Leibovich and UISS score, concordance index of these models were evaluated. Results:In 1 346 cases of our cohort, those with chromophobe RCC were well prognostic, survival were relatively better in clear cell RCC than that of papillary RCC, and worst prognosis were demonstrated in those with other types of RCC (5 year overall survival rate: 97.5%, 87.9%, 79.7% and 68.4% separately). Poor prognosis were seen in those older than 50 years, with poor T stage or nuclear grade, large tumor size and tumors with necrosis or sacromatoid differentiation ( P<0.05). In 80 439 seer cases, the best prognosis was also seen in chromophobe RCC and the worst in other type of RCC separately (5 year overall survival rate: 96.3% and 85.3%). In addition, longer survival was seen in papillary RCC than clear cell RCC (5 year overall survival rate: 92.5% and 88.9%). However, similar results with our cohort were seen in Asian and American native subgroup of SEER cases (95.1%, 88.6%, 86.7%, 80.2% for chromophobe, clear cell, papillary and other types of RCC respectively). Poor prognosis were seen in those older than 50 years, males, Asian/ American Indian, poor T stage or nuclear grade and large tumor size ( P<0.05). Concordance index for SSIGN, Leibovich and UISS models in our cohort were 0.763-0.781, 0.725-0.752 and 0.641-0.660, respectively. The chromophobe RCC subgroup was relative better based on predictive value of prognosis models(c-index of UISS of 0.670-0.781, SSIGN and Leibovich of 0.733-0.903). Conclusions:In Asian RCC population, prognosis of chromophobe RCC is best, clear cell RCC is slightly better than papillary RCC, and the prognosis of other types of RCC is the worst. Concordance index of SSIGN and Leibovich in our cohort were higher than that of UISS, and the use value for predictive model was better in the chromophobe RCC subgroup.
3.Research on Patient Monitoring Alarms in ICU and NICU.
Xianliang HE ; Mengxing LIU ; Sanchao LIU ; Zehui SUN ; Cheng WANG ; Ye LI
Chinese Journal of Medical Instrumentation 2021;45(5):585-590
OBJECTIVE:
The patient monitors were used to explore the alarm actuality in a ICU and NICU to investigate the awareness and reaction of medical staff to alarms.
METHODS:
A series of surveys and interviews were taken to acquire clinicians' feelings and attitudes to monitoring alarms. The researchers were scheduled to track the alarms with annotations, and collect the alarm data of patient monitors using central monitoring system.
RESULTS:
A total of 235 387 and 67 783 alarms occurred in ICU and NICU respectively. The average alarm rate was about 142 alarms/patient-day in ICU and 96 alarms/patient-day in NICU.
CONCLUSIONS
There remains alarm fatigue in ICU and NICU, the main reason is the large number of false alarms and clinically irrelevant alarms. In addition, patient monitor is still in the level of threshold alarms or combined alarms, the data integrity and intelligence level need to be improved in future.
Clinical Alarms
;
Electrocardiography
;
Humans
;
Infant, Newborn
;
Intensive Care Units, Neonatal
;
Monitoring, Physiologic
4.Research of Methods to Reduce Alarm Fatigue of Monitoring System.
Mengxing LIU ; Zehui SUN ; Wenyu YE ; Sanchao LIU ; Xianliang HE ; Cheng WANG ; Ye LI
Chinese Journal of Medical Instrumentation 2020;44(6):481-486
OBJECTIVE:
In order to solve alarm fatigue, the algorithm optimization strategies were researched to reduce false and worthless alarms.
METHODS:
A four-lead arrhythmia analysis algorithm, a multiparameter fusion analysis algorithm, an intelligent threshold reminder, a refractory period delay technique were proposed and tested with collected 28 679 alarms in multi-center study.
RESULTS:
The sampling survey indicate that the 80.8% of arrhythmia false alarms were reduced by the four-lead analysis, the 55.9% of arrhythmia and pulse false alarms were reduced by the multi-parameter fusion analysis, the 28.0% and 29.8% of clinical worthless alarms were reduced by the intelligent threshold and refractory period delay techniques respectively. Finally, the total quantity of alarms decreased to 12 724.
CONCLUSIONS
To increase the dimensionality of parametric analysis and control the alarm limits and delay time are conducive to reduce alarm fatigue in intensive care units.
Alert Fatigue, Health Personnel/prevention & control*
;
Arrhythmias, Cardiac/diagnosis*
;
Clinical Alarms
;
Humans
;
Intensive Care Units
;
Monitoring, Physiologic
5.Development of Vital Signal Monitoring System Based on Accelerometer.
Jian CEN ; Xingliang JIN ; Sanchao LIU ; Huacheng LUO ; Nong YAN ; Xianliang HE ; Yumei MA ; Hanyuan LUO ; Jie QIN ; Yinbing YANG
Chinese Journal of Medical Instrumentation 2023;47(6):602-607
OBJECTIVE:
Reduce the number of false alarms and measurement time caused by movement interference by the sync waveform of the movement.
METHODS:
Vital signal monitoring system based on motion sensor was developed, which collected and processed the vital signals continuously, optimized the features and results of vital signals and transmitted the vital signal results and alarms to the interface.
RESULTS:
The system was tested in many departments, such as digestive department, cardiology department, internal medicine department, hepatobiliary surgery department and emergency department, and the total collection time was 1 940 h. The number of false electrocardiograph (ECG) alarms decreased by 82.8%, and the proportion of correct alarms increased by 28%. The average measurement time of non-invasive blood pressure (NIBP) decreased by 16.1 s. The total number of false respiratory rate measurement decreased by 71.9%.
CONCLUSIONS
False alarms and measurement failures can be avoided by the vital signal monitoring system based on accelerometer to reduce the alarm fatigue in clinic.
Humans
;
Monitoring, Physiologic
;
Electrocardiography
;
Arrhythmias, Cardiac
;
Blood Pressure
;
Accelerometry
;
Clinical Alarms