2.Reoperations for prosthetic valve replacement.
Young Sun YOO ; Young Moo KWON ; Sae Young CHOI ; Kwang Sook LEE
The Korean Journal of Thoracic and Cardiovascular Surgery 1991;24(11):1090-1097
No abstract available.
3.Clinical Usefulness of Transesophageal Echocardiography for Detection of LA Thrombi and Significance of Left Atrial Spontaneous Contrast.
Kee Sik KIM ; Young Sung SONG ; Yoon Nyun KIM ; Ki Young KWON ; Kwon Bae KIM ; Sae Young CHOI
Korean Circulation Journal 1992;22(4):599-606
BACKGROUND: To evaluate the efficacy of transesophageal echocardiography(TEE) to detect left atrial thrombi(LAT) and to investigate the clinical and echocardiography parameters which related with LAT. METHOD: We performed TEE and TTE simultaneously to 98 consecutive patients who had native mital valve disease or mital prosthesis as usual method. We examined the presence and location of LAT and spontaneous contrast(SC) in TEE and measured left atrial dimension(LAD), ejection fraction(EF), mital valve area(MVA) in TTE. Cardiac rhythm, history of anticoagulation and systemic embolization were also reviewed. We compared such parameters in LAT positive/negative groups and SC positive/negative groups. RESULTS: 1) In TEE, we detected 26 cases of LAT, among them seventeen cases : left atrial appendage(LAA) thrombi, 3 cases : combined LA and LAA thrombi, 6 cases : LA thrombi. In TTE, six cases showed LAT but we couldn't detect LAA thrombi. The difference between two methods was statistically significant(p<0.05). 2) LAT positive group showed larger LAD, lower EF, and higher prevalence of AF, systemic embolization, and LAT than negative groups(p<0.01). 3) SC positive group showed larger LAD, lower EF, higher prevalence of AF, systemic embolization LAT than SC negative groups(p<0.05). 4) In multiple discriminant analysis, the history of systemic embolization was most important factor which can suspect LAT(Wilk's Lambda:0.77152. p<0.0001). SC, EF, presence of AF, LAD, anticoagulation therapy. MVR were also statistically valuable factors in order. The hit ratio of this analysis was 86.84%. CONCLUSION: We can suggest that TEE is very useful method to detect LAT than TTE, and the spontaneous contrast was very important factor which can suggest LAT and systemic embolization in mitral valve disease.
Echocardiography
;
Echocardiography, Transesophageal*
;
Humans
;
Mitral Valve
;
Prevalence
;
Prostheses and Implants
4.Clinical experience of multiple valve replacement.
Chang Hoon CHO ; Sae Young CHOI ; Chang Kwon PARK ; Kwang Sook LEE ; Young Sun YOO
The Korean Journal of Thoracic and Cardiovascular Surgery 1992;25(11):1346-1353
No abstract available.
5.Serum and urine potassium changes during, and after extracorporeal circulation in open heart surgery.
Chang Hoon JO ; Sae Young CHOI ; Chang Kwon PARK ; Kwang Sook LEE ; Young Sun YOO
The Korean Journal of Thoracic and Cardiovascular Surgery 1992;25(1):17-22
No abstract available.
Extracorporeal Circulation*
;
Heart*
;
Potassium*
;
Thoracic Surgery*
6.Clinical Study on the Femoral Shaft Fracture in Adult
Ik Dong KIM ; Soo Young LEE ; Kwaeng Woo KWON ; Joo Chul IHIN ; Sae Dong KIM
The Journal of the Korean Orthopaedic Association 1977;12(4):763-767
The steadily increasing frequency of car accidents and industrial injuries have contributed to increasing numbers of injuries to the femoral shaft. Fractures of the femoral shaft have always created camplicated problems associated with long periods of immobilization, resultant functional disability and economic loss. The methods of treatment are variable, therefore it is important to choose the correct form of treatment. The authors have reviewed 67 fractures of the femoral shaft in 66 patients for the 5 years period from Jan., 1972 to Dec., 1976, who were treated in the department of Orthopedic Surgery, Kyoungpook National University Hospital. The results were as follows; 1. Most of fractures occured in person who are in their third and fourth decades. Male are predominant. 2, Eliciting causes were mainly traumatic and most of them were car accidents. 3. Middle third of the femur was most prevalent location of the fracture site, and comminuted type was most frequent in the fracture type. 4. The period of immobilization for femoral shaft fracture was 7 weeks for those treated with compression plate and Kuntscher nailing; 11. 7 weeks with conventional plate and screw fixation and 17. 8 weeks with skeletal traction. 5. Postoperative infection rate was 3% and infection was treated by conservative methods.
Adult
;
Clinical Study
;
Femur
;
Humans
;
Immobilization
;
Male
;
Orthopedics
;
Traction
7.Subungual Melanoma of Left Thumb: A Case Report
Ik Dong KIM ; Joo Choul IHIN ; Soo Young LEE ; Kwaeng Woo KWON ; Sae Dong KIM
The Journal of the Korean Orthopaedic Association 1979;14(3):399-402
The following case report concerns a rare subungual melanoma of left thumb which metastasized into the ipsilateral axilla. Subungual melanoma, or melanotic whitlow, is a malignant lesion requiring early diagnosis and urgent treatment. Unlike melanomas located elsewhere on the skin of the body, subungual melanomas are shielded by the nails, which handicaps the securing of a biopsy by the clinician. We report a case of subungual melanoma in a 61 year-old man who had a 6 months history of painful axillary mass.
Axilla
;
Biopsy
;
Early Diagnosis
;
Melanoma
;
Skin
;
Thumb
8.Effect of beta-glucan from Aureobasidium on dermal wound healing in diabetic C57BL/KsJ-db/db mouse model.
Sungho YUN ; Sae Kwang KU ; Young Sam KWON
Journal of Biomedical Research 2015;16(4):140-145
The objective of the present study was to examine the effects of beta-glucan originating from Aureobasidium on full-thickness skin wound healing in diabetic C57BL/KsJ-db/ db mouse models. In the diabetic C57BL/KsJ-db/db model, test articles were topically applied twice a day for 20 days starting from 1 day after wounding. The results were compared to that of MadecassolTM ointment (madecassol; 1% Centella asiatica extracts) topically applied at a concentration of 100 mg/kg. Treatment with beta-glucan resulted in significant (p<0.01 or p<0.05) and dose-dependent decreases in wound size compared with that of vehicle control showing increased wound size (WS, %). In addition, 50% contraction time (CT50) was dramatically and dose-dependently reduced, and inflammatory cells in granulation tissues of the wound area were significantly (p<0.01 or p<0.05) and dosedependently reduced compared with that of vehicle control showing increased numbers of micro-vessels and fibroblasts as well as re-epithelialization. In the madecassol group, similar changes in inflammatory cells and fibroblasts with re-epithelialization were also observed, but madecassol did not influence angiogenesis. No meaningful changes in body weight were detected in all tested groups compared with the vehicle control. Therefore, these data suggest that beta-glucan has a beneficial effect on diabetic delayed skin wound healing and may be useful to manage incurable skin wounds in diabetic animals.
Animals
;
Body Weight
;
Centella
;
Fibroblasts
;
Granulation Tissue
;
Mice*
;
Re-Epithelialization
;
Skin
;
Wound Healing*
;
Wounds and Injuries*
9.Traumatic diaphragmatic injuries: a report of 23 cases.
Sae Young CHOI ; Chan Young RA ; Jong Gon HA ; Chang Kwon PARK ; Kwang Sook LEE ; Young Sun YOO
The Korean Journal of Thoracic and Cardiovascular Surgery 1991;24(2):197-201
No abstract available.
10.Evaluation of functional regurgitation flow in patients with clinically normal mitral prosthesis by transesophageal echocardiography.
Yoon Nyun KIM ; Young Sung SONG ; Kee Sik KIM ; Kwon Bae KIM ; Seoung Ho HUH ; Sae Young CHOI
Korean Circulation Journal 1993;23(1):67-74
BACKGROUND: In vitro study, normal cardiac prosthetic valve has functional regurgitation due to structural characteristics of prosthetic valve. To evaluate functional regurgitant characteristics of prosthetic valves, we examined patients who had clinically normal mitral prosthesis. METHODS: Transesophageal two-dimensional and color doppler echocardiography were performed to 25 patients who had the clinically normal mitral prosthesis. RESULTS: Seven patients had the mitral bioprosthesis and 18 patients had the mitral mechanical prosthesis. Regurgitation was found in 4 patients(57%) with bioprosthetic valve, and the pattern of regurgitation was central in three patients and unilateral in one patient. But regurgitation was detected in 17 patients(94%) with mechanical prosthesis, and the pattern of regurgitation was bilateral in twelve patients, unilateral in four patients and central in one patient(p=0.0035). The length of regurgitant jets were 22.00+/-6.73(mm) in bioprosthetic valve and 28.65+/-7.33(mm) in mechanical valve. The regurgitant jets were detected in systolic period in most of patients. But in 4 patients who had tachycardia during TEE, regurgitation was detected in systolic and early diastolic period. CONCLUSION: Regurgitation was found in clinically normal cardiac prosthetic valves by TEE. These findings may be useful to differentiate between normal and abnormal cardiac prosthesis.
Bioprosthesis
;
Echocardiography, Doppler, Color
;
Echocardiography, Transesophageal*
;
Humans
;
Prostheses and Implants*
;
Tachycardia