1.Establishment of Cutoff Value in the Neonatal Screening Tests.
You Jeong KIM ; Ja Hyung KIM ; Sa Il CHEON ; Won Ki MIN ; Young Lim SHIN ; Han Wook YOO
Journal of Korean Society of Pediatric Endocrinology 2001;6(1):43-51
PURPOSE: This study was undertaken to determine the adequate cutoff value of the neonatal screening test to decrease recall and false-positive rates. METHODS: During the period of January 1999 through December in Asan Medical Center, newborn screening tests for phenylketonuria, congenital hypothyroidism, congenital adrenal hyperplasia, and galactosemia were performed in 3,775, 3,707, 3,783, and 3,806 newborns respectively using commercial ELISA kits. We reviewed and analyzed the recall rate at currently used cutoff values. RESULTS: 1)In neonatal screening test for congenital hypothyroidism, using a current cutoff value, 17 microIU/mL, the recall rate was 0.9% and using a 99.7% cutoff value, 21.3 microIU/mL, the predictive recall rate was 0.4%. There were no significant differences in the other reports that suggest adequate recall rate. 2)In neonatal screening test for phenylketonuria, using a current cutoff value, 3.6 mg/dL, the recall rate was 1.5% which was no significant difference compared with expected presumptive positive rate, 1.44%. 3)In neonatal screening test for congenital adrenal hyperplasia and galactosemia, the recall rate was high when using current cutoff value. But all results were within normal limits in reevaluation. CONCLUSION: The cutoff values of screening test which are currently recommended by manufacturers of commercial kits for congenital hypothyroidism, congenital adrenal hyperplasia and galactosemia, are needed to be reset to decrease the recall rate by false-positive results on the basis of data from an individual newborn screening laboratory.
Adrenal Hyperplasia, Congenital
;
Chungcheongnam-do
;
Congenital Hypothyroidism
;
Enzyme-Linked Immunosorbent Assay
;
Galactosemias
;
Humans
;
Infant, Newborn
;
Mass Screening
;
Neonatal Screening*
;
Phenylketonurias
2.Mucosal Incision and Forceps Biopsy for Reliable Tissue Sampling of Gastric Subepithelial Tumors.
Sa Young SHIN ; Sang Jin LEE ; Jae Hyuck JUN ; Jong Kyu PARK ; Hyun Il SEO ; Koon Hee HAN ; Young Don KIM ; Woo Jin JEONG ; Gab Jin CHEON
Clinical Endoscopy 2017;50(1):64-68
BACKGROUND/AIMS: The diagnostic efficacy of current tissue sampling techniques for gastric subepithelial tumors (SETs) is limited. Better tissue sampling techniques are needed to improve pathological diagnosis. The aim of this study was to evaluate the safety and efficacy of a new technique, mucosal incision and forceps biopsy, for reliable tissue sampling of gastric SETs. METHODS: This study enrolled 12 consecutive patients who underwent mucosal incision and forceps biopsy of gastric SETs between November 2011 and September 2014 at Gangneung Asan Hospital. The medical records of patients were reviewed retrospectively. The safety and diagnostic yield of this method were evaluated. RESULTS: By performing mucosal incision and forceps biopsy, we were able to provide a definitive histological diagnosis for 11 out of 12 cases. The pathological diagnoses were leiomyoma (3/11), gastrointestinal stromal tumor (GIST; 2/11), lipoma (2/11), schwannoma (1/11), and ectopic pancreas (3/11). In cases of leiomyoma (n=3) and GIST (n=2), tissue samples were of sufficient size to allow immunohistochemical staining. In addition, the mitotic index was evaluated in two cases of GIST. There were no procedure-related complications. CONCLUSIONS: Mucosal incision and forceps biopsy can be used as one of several methods to obtain adequate tissue samples from gastric SETs.
Biopsy*
;
Chungcheongnam-do
;
Diagnosis
;
Gangwon-do
;
Gastrointestinal Stromal Tumors
;
Gastroscopy
;
Humans
;
Leiomyoma
;
Lipoma
;
Medical Records
;
Methods
;
Mitotic Index
;
Neurilemmoma
;
Pancreas
;
Retrospective Studies
;
Stomach
;
Surgical Instruments*