1.A Study on the Mechanism of Integrity Educational for Medical Students from the Perspective of Socialist-Cored Values
Chinese Medical Ethics 1994;0(05):-
Integrity education,as the main content of strengthening and improving ideological and political education of medical students,is an important part in building the socialist-cored value system and plays a key role in cultivating high-quality medical talents.This paper analyzes the connotations of integrity education from the perspective of socialist-cored value system,clarifies its demonstrations and expounds on the reasons for the lack of integrity among medical students.A deep understanding of integrity education is proposed in order to enhance students' cognition of integrity.Various strategies should be applied in its implementation process,and innovations should be brought forth in practice to achieve an effective long-term mechanism of integrity education.
2.Analysis of influencing factors for outcomes of HIS use at three tertiary hospitals in Anhui
Runling WANG ; Changyong LIANG ; Dongxiao GU
Chinese Journal of Hospital Administration 2015;31(1):55-58
Efficient use of the hospital information system can protect and promote the orderly operation of medical practice.The HIS usage effect by the medical staff is mainly affected by individual mastery of information technology,IS technical level and the organizational environment.A survey and analysis of these three factors were made at three tertiary hospitals in Anhui,and the results indicate personal command of information technology,technology and organizational impact to bear significant positive impacts on medical staff' use effect.Based on the results,the paper proposed countermeasures and suggestions on strengthening the HIS construction and enhancing medical staffs HIS use effect.
3.Analysis of predisposing factors of hematoma enlargement in spontaneous intracerebral hemorrhage
Hong ZHANG ; Runling WANG ; Li CUI
Journal of Chinese Physician 2013;15(10):1315-1318
Objective To investigate the main predisposing factors of hematoma enlargement in spontaneous intracerebral hemorrhage,reduce the early mortality,and improve clinical outcomes.Methods By a retrospective study of 268 patients,all patients underwent their first computed tomography (CT)scan within 24 hours of arrival and a second CT scan within 72 hours of admission.These predisposing factors were analyzed by means of univariate and multivariate logistic regression analyses.Results The patients occurred early hematoma enlargement were accounted for 27.99% (75/268).Univariate analyses indicated that hematoma shape,midline shift,breaking into the ventricle,thrombin clotting time (TT),white blood cells,neutrophil percentage,serum creatinine,fasting plasma glucose (FPG),and Glasgow coma scale (GCS) were significantly different between the patients with or without hematoma enlargement (P <0.05).Furthermore,multivariate logistic regression analyses revealed that the following four factors were independently associated with hematoma enlargement:the midline shift [OR (95% CI) =3.356 (1.251-8.999),P =0.000],the GCS score [OR (95 % CI) =0.745 (0.671-0.827),P =0.023],the FPG [OR (95% CI) =3.022 (1.232-7.408),P =0.016],and the breaking into the ventricles [OR (95% CI) =2.851(1.158-7.019),P =0.005].Conclusions The midline shift of brain CT scan,the GCS score,the FPG,and the breaking into the ventricles maybe the independent predisposing factors of hematoma enlargement.Therefore,timely review of CT scan and dynamic monitoring of peripheral blood biochemical indicators should be very important for further therapy.
4.Comparisons on functional capacities of simple breathing balloon extruded by different hand types and methods
Ying WANG ; Aihong WANG ; Zhanbiao YOU ; Runling GUO ; Yaoyong WANG
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care 2017;24(3):287-289
Objective To observe the differences in functional capacities generated by different simple breathing balloons extruded by different hand types and methods.Methods The lung functional measurement instrument was used to measure the generated functional capacities of two types of simple breathing balloon extruded by different hand methods: using big-, mid- and small-size hands with 5 fingers generally separately open and maximally extended states or with both small-size hands to extrude balloon; the effective generated gas quantity of the above methods were compared.Results ① Comparison between different balloons: the functional capacity generated by black rubber balloon extruded by any hand type was 68 - 132 mL lower than that generated by light blue silicon balloon. ② The comparison between different hand types: the functional capacities generated by any hand at maximally extended state in extruding balloon was 13 - 70 mL higher than that by hand commonly separate state; extrusion by a small size hand was nearly unable to reach 400 mL, while the functional capacity was 520 - 650 mL when the balloon was extruded by a big size hand, and 435 - 635 mL by a mid-size hand; it was necessary to use both small hands when the black rubber balloon was extruded, when the light blue silicon air bag was extruded, the functional capacity could reach 430 - 440 mL with a small size hand. ③ Difference in extruding methods: the functional capacity generated by either big size hand or mid-size hand with 5 fingers maximally extending state to extrude balloon was significantly higher than that with 5 fingers commonly separate state, the functional capacity generated by both small size hands with fingers maximally separating and extending state to extrude balloon was obviously higher than that generated by 5 fingers generally separating and extending state, the functional capacities generated by light blue silicon balloon were obviously higher than those by black rubber balloon, no matter the 5 fingers of big- or mid-size hand being at generally separating or extending state (mL: 623.00±21.11 vs. 522.00±41.85 by big size hand with common 5 fingers separate state, 649.00±26.01 vs. 575.00±58.55 by big sizehand with maximum 5 fingers extending state; 566.00±37.77 vs. 436.00±21.19 by mid-size hand with common 5 fingers separate state, 637.00±30.02 vs. 505.00±37.49 by mid-size hand with maximum 5 fingers extending state); the light blue silicon balloon extruded by small hand with 5 fingers at generally separate state and at maximally extending state could generate functional capacities (mL)432.00±13.02 and 444.00±37.18 respectively, significantly higher than those using the 2 types of hand state extruding a black rubber balloon (the tidal volume < 400 mL), the functional capacities generated by both small hands extruding a light blue silicon balloon was obviously higher than that by using a black rubber balloon (mL: 557.00±54.98 vs. 489.00±40.12, allP < 0.05).Conclusions Different functional capacities will be generated by different hand sizes, different hand extruding methods and types of simple breathing balloon, clinical application should be based on patients' body weights to decide their tidal volumes, and combined with the rescuers' hand sizes and types of simple breathing balloon to choose a proper extruding method for a certain patient, thus sufficient oxygen can be surely provided in time for him/her and rescue successful rate can be elevated.
5.Relationship of sub-health and alexithymia among medical students
Congyun LIU ; Fangbiao TAO ; Qiang WU ; Yuhui WAN ; Runling WANG
Journal of Third Military Medical University 2002;0(12):-
P75 was the risk factor (PP50 were risk factors (P
7.Pathogens Causing Chronic Prostatitis and Their Resistance
Yingfang WANG ; Ling MENG ; Yaping XU ; Runling ZHANG
Chinese Journal of Nosocomiology 2006;0(12):-
OBJECTIVE To comprehend the bacterial infection and resistance to antimicrobial agents of the pathogenic bacteria causing chronic prostatitis(CP),so as to provide scientific basis for the diagnosis and treatment of CP.METHODS Bacterial culture and antimicrobial agents sensitivity tests were applied to prostatic fluid in 143 patients with chronic prostatitis.RESULTS A total of 85 strains of bacteria were isolated from 143 clinical specimens and the positive rate was 57.34%.In these strains,Gram-positive cocci were the most predominant accounted for 85.9%,coagulase negative Staphylococcus(CNS) were the highest ones and accounted for 60.0% among Gram-positive cocci.S.aureus and Entercoccus were respectively accounted for 12.9% and 11.8%.The ratio of drug resistance of CNS was high for ?-lactamases,quinolones,erythromycin and tetracycline and they were more sensitive to vancomycin,rifampicin,sulfamethoxazle/trimethoprim and gentamicin.CONCLUSIONS The major pathogens in prostatic fluids were CNS.The chronic prostatitis causing by CNS can be treated by rifampicin,sulfamethoxazle/trimethoprim and gentamicin.It is key to treatment of CP to select the sensitive and infiltrative drug for prostate.
8.Application of Venturi combined with MR850 in ventilator offline patients with tracheotomy
Runling GUO ; Ying WANG ; Yaoyong WANG ; Yongqiang LI
Chinese Critical Care Medicine 2018;30(10):943-945
Objective To investigate the effect of oxygen therapy with Venturi combined with MR850 heating humidifier on patients without mechanical ventilation after tracheotomy. Methods Eighty patients (≥ 18 years old) who had undergone tracheotomy and without mechanical ventilation admitted to Fenyang Hospital of Shanxi Province from June 2016 to December 2017 were enrolled, and they were divided into control group and observation group according to random number table method, with 40 patients in each group. The observation group was given Venturi (removed the mask) combined with MR850 device active warm and humid oxygen therapy; the control group was given one-off ordinary flow device and warm and humid exchanger (artificial nose, HME) passive humid oxygen therapy. Body temperature increased by 1 ℃ above basal body temperature, white blood cell count (WBC) increased 2×109/L than the base value, oxygenation index (PaO2/FiO2) < 300 mmHg (1 mmHg = 0.133 kPa), airway mucosal hemorrhage, pulmonary infection and sputum viscosity were observed in the two groups for 5 days after oxygen therapy. Results Among the 80 patients, there were 46 males and 34 females, with an average age of (67.7±12.2) years. Compared with the control group, the incidence of increased body temperature (5.0% vs. 20.0%), the incidence of increased WBC (7.5% vs. 35.0%), the incidence of low PaO2/FiO2(2.5% vs. 7.5%), the incidence of airway mucosal bleeding (5.0 % vs. 15.0%) and the incidence of pulmonary infection (2.5% vs. 10.0%) were significantly decreased in the observation group (all P < 0.01), and the proportion of sputum viscosity Ⅰ degree of patients was significantly increased (57.5% vs. 12.5%, P < 0.01). Conclusion Venturi combined with MR850 device can effectively control airway temperature and humidity, promote sputum dilution and conducive to drainage, reduce pulmonary infection in adults patients without mechanical ventilation after tracheotomy, thereby reducing postoperative complications of tracheotomy.
9.Accuracy of low dose dobutamine,isosorbide dinitrate alone and in combination stress echocardiography for identifying viable myocardium in patients with old myocardial infarction and severe left ventricular dysfunction:compared with ~(99m)Tc-MIBI/~(18)FDG
Weixian YANG ; Yuejin YANG ; Rongfang SHI ; Fenghuan HU ; Shijie YOU ; Yueqin TIAN ; Zuoxiang HE ; Yanwu WANG ; Ling YE ; Jilin CHEN ; Runling GAO ; Zaijia CHEN
Chinese Journal of Ultrasonography 1997;0(06):-
(0.05)). The sensitivity and the agreement rate were best at dose of Dob 10 ?g?kg~(-1)?min~(-1) with (86.5)% and (86.5)% (Kappa(0.71)), respectively. When Isoket combined with Dob 3,5 ?g?kg~(-1)?min~(-1), the sensitivities and the agreement rates were both significantly improved than either one used (both P
10. Personal dose monitoring of radiation workers in medical institutions at the municipal level and below in a city from 2011 to 2014
Chang WANG ; Sufang MO ; Jingbo ZHANG ; Jinrong LI ; Runling HUANG ; Hanyun TAN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2017;35(8):594-597
Objective:
To determine the personal dose level of radiation workers in medical institutions at the municipal level and below in a city, and to provide a scientific support for strengthening the radiation protection in the city’s medical institutions.
Methods:
Information of the successful applicants for the "Radiation Worker Permit" from 174 medical institutions at the municipal level and below was collected from October 1, 2011 to December 31, 2014. The annual effective dose was calculated based on the personal dose monitoring report, and indicators including sex, permit application time, hospital level, type of occupational radiation, length of radiation work, blood test, and micronucleated lymphocyte rate were analyzed.
Results:
Of the 1 143 radiation worker permit applications submitted by medical institutions the municipal level and below in this city from 2011 to 2014, 1 123 provided at least one personal dose monitoring report. The annual effective dose of the radiation workers was 0-4.76 mSv (mean 0.31±0.40 mSv) , and the collective annual effective dose was 351.96 mSv. The annual effective dose was significantly different between radiation workers with different times of permit application, hospital levels, and types of occupational radiation (