1.Association between osteoprotegerin gene G1181C polymorphism and bone mineral density in postmenopausal women:A Meta-analysis
Hao ZHANG ; Lu GAN ; Yan GUO ; Ruiheng WANG
Chinese Journal of Tissue Engineering Research 2013;(37):6695-6700
BACKGROUND:Genetic studies have shown that there may be association between osteoprotegerin gene G1181C polymorphism and bone mineral density in postmenopausal women, but there are some differences in the conclusions.
OBJECTIVE:To study the association between osteoprotegerin gene G1181C polymorphism and bone mineral density in postmenopausal women through Meta-analysis.
METHODS:The PubMed database, Embase database, CNKI database and Wanfang database were searched for the observational studies about the association between osteoprotegerin gene G1181C polymorphism and bone mineral density in postmenopausal women. The standardized mean difference was considered as the effect indicator and calculated with random or fixed effect models according to the significance of heterogeneity.
RESULTS AND CONCLUSION:A total of 9 articles were included with a total of 8 799 and 9 365 participants for which vertebral and spine bone mineral density had been measured, respectively. The analysis results showed that the bone mineral density of the postmenopausal women with the G al ele of G1181C was significantly lower than that of the postmenopausal women with the C al ele. Similar results were obtained in Caucasian population subgroup analysis. The Caucasian population subgroup analysis showed that the bone mineral density of the postmenopausal women with GG genotype of G1181C was lower than that of the postmenopausal women with GC and CC genotype. The results indicate that there is association between osteoprotegerin gene G1181C polymorphism and bone mineral density in postmenopausal women, and G al ele is a risk factor for lower bone mineral density.
2.Measurement and characterization of retinal vascular morphology parameters based on artificial intelligence automated analysis technology
Xuhan SHI ; Li DONG ; Lei SHAO ; Saiguang LING ; Zhou DONG ; Ying NIU ; Ruiheng ZHANG ; Wenda ZHOU ; Wenbin WEI
Chinese Journal of Experimental Ophthalmology 2024;42(1):38-46
Objective:To analyze retinal vascular parameters and distribution characteristics in Chinese population via the fully automated quantitative measurement of retinal vascular morphological parameters based on artificial intelligence technology.Methods:A cross-sectional study was performed.A total of 1 842 patients without fundus diseases who visited Beijing Tongren Hospital from January 2011 to December 2021 were included.Standardized questionnaires, blood draws and ophthalmologic examinations of enrolled subjects were conducted.Color fundus photographs centered on the optic disk of one eye of patients were collected, and a deep learning-based semantic segmentation network ResNet101-Unet was used to construct a vascular segmentation model for fully automated quantitative measurement of retinal vascular parameters.The main measurement indexes included retinal vascular branching angle, vascular fractal dimension, average vascular caliber, and average vascular tortuosity.To compare different retinal parameters between sexes, the correlation between the above parameters and ocular factors such as best corrected visual acuity, intraocular pressure, and axial length, as well as systemic factors such as sex, age, hypertension, diabetes mellitus, and cardiovascular disease was analyzed.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Beijing Tongren Hospital, Capital Medical University (No.20001220). Written informed consent was obtained from each subject.Results:The model established in this study achieved an accuracy over 0.95 for both vascular and optic disk segmentation.The vascular branching angle, vascular fractal dimension, average vascular caliber, and average vascular tortuosity were (51.023±11.623)°, 1.573(1.542, 1.592), 64.124(60.814, 69.053)μm, (0.001 062±0.000 165)°, respectively.Compared with females, males had larger vascular branching angle, smaller average vascular caliber and smaller vascular tortuosity, and the differences were statistically significant (all at P<0.05). The average vascular caliber increased by 1.142 μm in people with cardiovascular disease compared to people without cardiovascular disease ( B=1.142, P=0.029, 95% CI: 0.116-2.167). The average vascular tortuosity was positively correlated with hypertension ( B=3.053×10 -5, P=0.002, 95% CI: 1.167×10 -5-4.934×10 -5) and alcohol consumption ( B=1.036×10 -5, P=0.014, 95% CI: 0.211×10 -5-1.860×10 -5) and negatively correlated with hyperlipidemia ( B=-2.422×10 -5, P=0.015, 95% CI: -4.382×10 -5-0.462×10 -5). For each 1-mm increase in axial length, there was a decrease of 0.004 in vessel fractal dimension ( B=-0.004, P<0.001, 95% CI: -0.006--0.002), a decrease of 0.266 μm in the average vessel caliber ( B=-0.266, P=0.037, 95% CI: -0.516--0.016), and a decrease of -2.45×10 -5° in the average vessel tortuosity ( B=-2.45×10 -5, P<0.001, 95% CI: -0.313×10 -5--0.177×10 -5). For each 1.0 increase in BCVA, there was an increase of 3.992° in the vascular branch angle ( B=3.992, P=0.004, 95% CI: 1.283-6.702), an increase of 0.090 in vascular fractal dimension ( B=0.090, P<0.001, 95% CI: 0.078-0.102) and a decrease of 14.813 μm in the average vascular diameter ( B=-14.813, P<0.001, 95% CI: -16.474--13.153). Conclusions:A model for retinal vascular segmentation is successfully constructed.Retinal vessel parameters are associated with sex, age, systemic diseases, and ocular factors.
3.Evaluation of plasma exosomal miR-214-3p as a potential biomarker for diagnosis and prognosis of uveal melanoma
Wenda ZHOU ; Lei SHAO ; Li DONG ; Xuhan SHI ; Ruiheng ZHANG ; Heyan LI ; Haotian WU ; Wenbin WEI
Chinese Journal of Experimental Ophthalmology 2022;40(8):734-741
Objective:To investigate the differential expression of microRNA (miR)-214-3p in plasma exosomes in different types of uveal melanoma (UM) and evaluate whether miR-214-3p is a potential molecular biomarker for the diagnosis and prognosis of UM.Methods:Twenty-five UM in situ patients who received the enucleation of eyeball were enrolled at Beijing Tongren Hospital from December 2015 to October 2019, including 10 with epithelioid cell melanoma and 10 with spindle cell melanoma as well as 5 metastatic UM patients (1 with spindle cell-like melanoma and 4 with epithelioid cell-like melanoma) and 10 healthy subjects were enrolled during the same period.Blood sample was collected from all the subjects for the isolation of plasma exosomes.The morphology of exosomes was examined under the electron microscope.The exsomal marker proteins were identified by Western blot.The expression level of miR-214-3p in plasma exosomes was detected by real-time fluorescence quantitative PCR.The differential expression of miR-214-3p among different types of UM patients and healthy controls was compared.The diagnostic and classification performance of exosomal miR-214-3p was evaluated using receiver operating characteristic curve.Written informed consent was obtained from each subject prior to entering the study cohort.This study protocol was approved by an Ethics Committee of Capital Medical Univeristy (No.TRECKY2018-056).Results:The isolated exosomes were hemispherical in shape with a concavity on one side.The diameter of the exosomes was about 100 nm and the particle diameter of vesicles from samples was (82.0±2.7) nm.TSG101 protein was detectable and Calnexin protein was not found in the exosomes.The relative expression levels of plasma exosomal miR-214-3p in healthy control group, in situ UM group and metastatic UM group were 0.86(0.57, 1.49), 0.24(0.10, 0.67), and 0.43(0.23, 0.56), respectively.The miR-214-3p relative expression level in plasma exosomes of in situ UM patients and metastatic UM patients was significantly lower than that of healthy controls, and the differences were statistically significant ( Z=2.62, P<0.01; Z=2.08, P<0.05). The relative expression levels of exosomal miR-214-3p in spindle cell-like UM group and epithelioid cell-like UM group were 0.11(0.07, 0.64) and 0.46(0.14, 0.91), respectively, and no significant difference was found in the expression level of plasma exosomal miR-214-3p among different types of UM (all at P>0.05). The area under the curve of plasma exosomal miR-214-3p for UM diagnosis was 0.795. Conclusions:Plasma exosomal miR-214-3p level is significantly reduced in both in situ UM patients and metastatic UM patients.Plasma exosomal miR-214-3p is a new potential diagnostic biomarker for UM, but the exosomal miR-214-3p appears to not be able to distinguish the types of UM.
4.Phage antibody library technology in tumor therapy: a review.
Xiaoyang CHEN ; Ruiheng AN ; Ju HUANG ; Youfeng LIANG ; Wenjing ZHANG ; Mingxuan HAO ; Rui GUO ; Xiaoning LI ; Yongchao LI ; Lu YING ; Zhao YANG
Chinese Journal of Biotechnology 2023;39(9):3644-3669
Tumor is a serious threat to human health. At present, surgical resection, chemoradiotherapy, targeted therapy and immunotherapy are the main therapeutic strategies. Monoclonal antibody has gradually become an indispensable drug type in the clinical treatment of cancer due to its high efficiency and low toxicity. Phage antibody library technology (PALT) is a novel monoclonal antibody preparation technique. The recombinant immunoglobulin variable region of heavy chain (VH)/variable region of light chain (VL) gene is integrated into the phage vector, and the antibody is expressed on the phage surface in the form of fusion protein to obtain a diverse antibody library. Through the process of adsorption-elution-amplification, the antibody library can be screened to obtain the antibody molecule with specific binding antigen as well as its gene sequence. PALT has the advantages of short antibody production cycle, strong plasticity of antibody structure, large antibody yield, high diversity and direct production of humanized antibodies. It has been used in screening tumor markers and preparation of antibody drugs for breast cancer, gastric cancer, lung cancer and liver cancer. This article reviews the recent progress and the application of PALT in tumor therapy.
Humans
;
Bacteriophages/genetics*
;
Immunoglobulin Variable Region/genetics*
;
Gene Library
;
Antibodies, Monoclonal/therapeutic use*
;
Immunotherapy
;
Peptide Library