1.Characteristics of paravertebral muscles in patients with unilateral lumbar disc herniation
Xingxing SHEN ; Weijian CHEN ; Congcong LI ; Junyi LI ; Shuai WANG ; Zixuan YE ; Ruian XIANG ; Xuemeng XU
Chinese Journal of Rehabilitation Theory and Practice 2023;29(9):1098-1103
ObjectiveTo explore the imbalance of paravertebral muscle group for patients with unilateral lumbar disc herniation. MethodsFrom January, 2022 to January, 2023, 30 patients with unilateral lumbar disc herniation (observation group) and 30 healthy people matching in general data (control group) were measured the tension and stiffness of multifidus and erector spinae with MyotonPRO, while the observation group was assessed with Visual Analogue Scale (VAS) for pain and Japanese Orthopaedic Association (JOA) score, and the time of disease was also recorded. ResultsThe mean of bilateral tension and hardness of multifidus and erector spinae was more in the observation group than in the control group (|t| > 5.407, P < 0.001), and the tension and hardness of multifidus and erector spinae of the affected side were more than those of the unaffected side in the observation group (|t| > 11.219, P < 0.001). The tension and hardness of multifidus and erector spinae of the affected side were positively correlated with VAS score (r > 0.942, P < 0.001), and negatively correlated with JOA score (|r| > 0.886, P < 0.001). ConclusionThe tension and hardness of multifidus and erector spinae of the affected side increase after unilateral lumbar disc herniation, resulting in asymmetry.
2.Difference of cervical and shoulder muscle performance and its correlation with pain and body mass index in patients with chronic neck pain
Xingxing SHEN ; Yuling XIONG ; Weijian CHEN ; Congcong LI ; Junyi LI ; Shuai WANG ; Jiahao ZHANG ; Ruian XIANG ; Jiahao CHEN ; Wengang LIU ; Xuemeng XU
Chinese Journal of Rehabilitation Theory and Practice 2023;29(12):1420-1428
ObjectiveTo test the inter-tester reliability and test-retest reliability of MyotonPRO for evaluating neck and shoulder muscle performance parameters in patients with unilateral chronic neck pain, observe the difference of muscle performance between the healthy and affected sides of patients with chronic neck pain, and analyze the factors that cause the imbalance of muscle performance in patients with chronic neck pain. MethodsFrom January to June, 2023, 32 patients with unilateral chronic neck pain in Guangdong Second Traditional Chinese Medicine Hospital were selected. Two testers used the same MyotonPRO equipment to measure the muscle tone, muscle hardness and muscle elasticity on both sides of the sternocleidomastoid muscle and the upper trapezius muscle in the relaxed position. Tester 1 repeated the measurement after an interval of 30 minutes, and Tester 2 was measured within the time interval between the two measurements of Tester 1. The intraclass correlation coefficient (ICC), standard error of mean (SEM) and minimum detectable change (MDC) were calculated simultaneously. The measurement results were plotted into Bland-Altman diagram and systematic bias analysis was performed. The difference in muscle characteristics between the affected side and the healthy side was compared. At the same time, the Visual Analogue Scale (VAS) score and body mass index (BMI) of the subjects were collected for correlation analysis. ResultsExcept the sternocleidomastoid muscle elasticity of the affected side (ICC = 0.697), the inter-tester reliability of all other parameters was high to very high (ICC = 0.719 to 0.952, SEM = 0.04 to 6.53, MDC = 0.12 to 18.11). The test-retest reliability of all parameters was high (ICC = 0.883 to 0.981, SEM = 0.03 to 5.72, MDC = 0.09 to 15.84). Bland-Altman plot analysis showed that the scatter distribution was consistent. The muscle tone, muscle hardness and muscle elasticity of sternocleidomastoid muscle and upper trapezius muscle were higher on the affected side than on the healthy side (t > 2.846, P < 0.05). The asymmetry index of tension, hardness and elasticity of upper trapezius muscle and sternocleidomastoid muscle was significantly positively correlated with VAS score and BMI (r > 0.385, P < 0.05). ConclusionMyotonPRO has good inter-tester reliability and retest reliability in evaluating the muscle performance of both sides of patients with chronic neck pain. The muscle tone, muscle hardness and muscle elasticity of sternocleidomastoid muscle and upper trapezius muscle on the affected side were higher than on the healthy side, and the difference of muscle performance was positively correlated with pain and BMI.
3.Reliability on evaluation of quadriceps femoris muscle quality by ultrasonic echo intensity in patients with knee osteoarthritis
Junyi LI ; Zehua CHEN ; Zugui WU ; Yi WANG ; Congcong LI ; Shuai WANG ; Weijian CHEN ; Zixuan YE ; Xingxing SHEN ; Ruian XIANG ; Wengang LIU ; Xuemeng XU
Chinese Journal of Rehabilitation Theory and Practice 2023;29(6):738-744
ObjectiveTo evaluate the inter-rater and test-retest reliability of echo intensity of ultrasound image for quality of quadriceps femoris in patients with knee osteoarthritis (KOA). MethodsFrom March to December, 2021, 33 patients with unilateral KOA in Guangdong Provincial Second Hospital of Traditional Chinese Medicine were included. Ultrasound was used to observe the cross sections of rectus femoris (RF), vastus medialis (VM) and vastus lateralis (VL), and the images were saved. Two independent raters analyzed the average gray value of the picture with the Image J. One of the raters repeated the measurement. The intra-class correlation coefficient (ICC), standard error of measurement (SEM), minimum detectable change (MDC) and coefficient of variation (CV) were calculated and the Bland-Altman charts were drawn. ResultsThe gray value was higher in the RF, VM and VL in the affected side than in the healthy side (t > 2.262, P < 0.05). The inter-rater reliability was excellent, with ICC 0.982 to 0.995, SEM 1.60 to 3.82, CV 1.49% to 5.90%, and MDC value 4.43 to 10.59. The test-retest reliability of the rater was excellent, with ICC 0.969 to 0.990, SEM 2.37 to 5.41, CV 2.22% to 4.84%, and MDC value 6.57 to 15.00. Bland-Altman charts analysis showed that the consistency was good. ConclusionThe quadriceps femoris muscle quality is different between the affected and the healthy sides in patients with unilateral KOA. It is reliable to evaluate muscle echo intensity by Image J.