1.Relationship between neuronal ?4?2 nicotinic acetylcholine receptor and neurological diseases
hui-zhen, NIE ; wei, LI ; rui-li, NIE ; ming, YIN
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(06):-
Neuronal?_4?_2 nicotinic acetylcholine receptors(nAChRs) are the most widespread subtypes in central nervous system.?_4?_2 nAChRs mainly exist in procerebrum,parietal lobe cortex,temporal lobe cortex,hippocampus,basal ganglion and cerebellum.Researches on gene knock-out mice have demonstrated that?_4?_2 receptors participate in the development,aging,neuron survival,pain,and learning and memory,and are also involved in gamma-aminobutyric acid release and dopaminergic function.Studies have disclosed that?_4?_2 nAChRs relate to the development of variety of neurological diseases,including pain,Alzheimer's disease and Parkinson's disease.
2.Relationship between neuronal α4β2 nicotinic acetylcholine receptor and neurological diseases
Hui-zhen, NIE ; Wei, LI ; Rui-li, NIE ; Ming, YIN
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(6):744-746
Neuronal α4β2 nicotinic acetylcholine receptors (nAChRs) are the most widespread subtypes in central nervous system, α4β2 nAChRs mainly exist in procerebrum, parietal lobe cortex, temporal lobe cortex, hippocampus, basal ganglion and cerebellum. Researches on gene knock-out mice have demonstrated that α4β2 receptors participate in the development, aging, neuron survival, pain, and learning and memory, and are also involved in gamma-aminobutyric acid release and dopaminergic function. Studies have disclosed that α4β2 nAChRs relate to the development of variety of neurological diseases, including pain, Alzheimer's disease and Parkinson's disease.
3.Separation of polyphyllin from Rhizoma Paridis by foam fractionation technique
Jie LAN ; Rui LI ; Li HAN ; Ming YANG ; Jin WANG
Chinese Traditional and Herbal Drugs 1994;0(01):-
Objective To study the process of foam fractionation of polyphyllin in semi-batch mode. Methods Taking enrichment ratio, recovery rate of polyphyllin, and purity ratio as the performance criteria and using single examining method to examine the operational parameters, i.e. operation mode, air flow rate, initial feed concentration, solution pH value, initial feed height and temperature on separation performance. The optimal conditions of the process were obtained finally. Results The separation performance is good when gas flow rate is 400 mL/min, initial feed concentration (polyphyllins content) is 0.3 mg/mL, pH value is 7, feed height is 30 cm, and feed temperature is 40 ℃. The enrichment ratio is 25.7, recovery ratio is 42.1%, and the foam liquids purity of total polyphyllin is 41.4%, which is 4.5 times higher than that in feed purity. Conclusion Foam fractionation technique could be applied to separate polyphyllin.
4.Observation on clinical therapeutic effect of Alprostadil combined with Magnesium Isoglycyrrhizinate on patients with Hepatocirrhosis at active phase
Hong LI ; Yuan HE ; Ming WEI ; Rui HE
Chinese Journal of Primary Medicine and Pharmacy 2010;17(22):3068-3069
Objective To evaluate the effect of Alprostsdil combined with Magnesium Isoglycyrrhizinate on hepatocirrhosis at active phase. Method 74 inpatients collected from our hospital were randomly divided into control group(37 cases)and treatment group(37 cases). The patients in control group were given conventional liver protecting treatment. In addition to routine therapy of the control group, the patients in treatment group received intravenous Alprostadil and Magnesium Isoglycyrrhizinate injection once a day for 4 weeks. Results The total effective rate of treatment group was 67. 6%, and that of control group was 40. 5%, and the difference was significant (P < 0. 05).Conclusion Alprostadil combined with Magnesium Isoglycyrrhizinate has good clinical therapeutic effect on hepatocirrhosis at active phase.
6.The diagnostic value of anti-mutated citrullinated vimentin antibody in patients with rheumatoid arthritis
Rui FENG ; Yong-Zhe LI ; Guan-Fei ZHAO ; Ming JIANG ;
Chinese Journal of Rheumatology 2003;0(11):-
Objective To investigate the significance of anti-mutated citrullinated vimentin(MCV)an- tibody in rheumatoid arthritis(RA)and study the correlation among anti-CCP,other antoantibodies and clinical manifestations of RA.Methods Anti-MCV antibody was detected by enzyme-linked immunosorbent assay (ELISA)in 166 serum samples including 74 from RA(18 cases with early RA and 56 cases with late RA),50 from non-RA rheumatic diseases and 42 cases of healthy blood donors.At the same time,other antuoantibod- ies were detected by different techniques,and their clinical meaning was investigated with the corresponding clinical data.Results Anti-MCV was found in 78%(58/74)of RA.The sensitivity and specificity of Anti- MCV in RA were 78% and 95%.The positive and negative predictive value was 97% and 71%.The average cut off concentration of Anti-MCV was(552?380)U/ml in RA,(162?63)U/ml in non-RA and(63?46)U/ml in healthy control.Anti-MCV was strongly correlated to anti-CCP(r=0.502,P=0.000),then AKA(r=0.408)anti APF(r=0.369).No differences was found between Anti-MCV and other clinical/laboratory parameters(P>0.05). Conclusion Anti-MCV antibody may be a valuable diagnostic parameter for RA.Anti-MCV is more strongly correlated to anti-CCP than APE and AKA.It may not relate to disease activity and/or severity.
7.Clinical use of AO three-dimensionally preformed titanium mesh plates for orbital fractures
Ming, CHEN ; Guang-Rui, CHAI ; Meng, WANG ; Lu, LIU ; He-Ming, LI ; He, ZHANG
International Eye Science 2015;(1):112-116
Abstract?AlM:To evaluate the accuracy and practicability of three - dimensionally preformed Arbeitsgemeinschaft Osteosynthese AO titanium mesh plates for orbital fractures.?METHODS:Forty-seven patients with isolated blow-out orbital fractures were included in this study. Fracture locations were as follows: floor/medial wall ( n = 26, 55%), medial wall ( n = 12, 26%), and floor ( n = 9, 19%) . The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures with temporary dissection of inferior oblique muscle. A three -dimensionally preformed AO titanium mesh plate was selected according to the size of the defect previously measured on the preoperative computed tomographic scan examination and fixed at the inferior orbital rim with 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative computed tomography ( CT) scan. The practicability of clinical use of AO three - dimensionally preformed titanium mesh plates was assessed on the preoperative and postoperative clinical data.?RESULTS: Postoperative orbital CT scan showed an anatomic three- dimensional placement of the orbital mesh plates in all of the patients. All patients had a successful treatment outcome without clinical complications. 40 patients ( 87%) had a successful enophthalmos correction. 25 patients ( 86%) had a successful recovery from diplopia.?CONCLUSlON: Three- dimensionally preformed AO titanium mesh plates for orbital fracture reconstruction results in an accurate anatomic restoration of the bony orbital contour with a high rate of success to correctenophthalmos and diplopia.
8.Effect of modified mahuang fuzi xixin decoction extract on atrioventricular block induced by ischemia/reperfusion in New Zealand rabbits.
Rui-ming LI ; Ming-sheng ZHANG
Chinese Journal of Integrated Traditional and Western Medicine 2008;28(12):1104-1107
OBJECTIVETo study the effects of modified Mahuang Fuzi Xixin Decoction extract (MFXDE) on ischemia/reperfusion induced atrioventricular (A-V) block in rabbits model.
METHODSNew Zealand rabbits were randomly divided into six groups, three test groups (Group TA, TB, TC) and three control groups (Group CA, CB, CC), 10 in each. MFXDE 2 mL/kg was given twice a day by gastrogavage to the test groups, while to the control groups, equal volume of normal saline was given instead, for 3 successive days. Twenty minutes after the last gastrogavage, right coronary artery ligation was performed in rabbits under anesthesia with 1.2 g/kg of 20% urethane via ear marginal vein injection, and lasted for 15 min (Group TA and CA), 60 min (Group TB and CB), and 120 min (Group TC and CC), respectively. ECG lead-II and His Bundle ECG were recorded at different time points to observe P-R interval and A-H interval.
RESULTSP-R interval and A-H interval in the test groups were shorter than in the control groups significantly (all P < 0.05) at the time point of 5 min after ischemia; and at the reperfusion stage, a re-extending phenomenon of P-R and A-H could be found in the CC group after 60 min reperfusion (P < 0.05), but it didn't occure in all the other test groups.
CONCLUSIONMFXDE could improve the ischemia/reperfusion induced A-V conductive function.
Animals ; Atrioventricular Block ; drug therapy ; etiology ; physiopathology ; Disease Models, Animal ; Drugs, Chinese Herbal ; administration & dosage ; Female ; Humans ; Male ; Myocardial Reperfusion Injury ; complications ; Rabbits ; Random Allocation
9.Effect of LASIK using Ziemer LDV Z6 femtosecond laser for creating corneal flaps
Meng-Meng, WANG ; Jing-Jing, WANG ; Rui-Fang, LI ; Ming-Ran, LI ; Li-Yan, LI
International Eye Science 2016;16(11):2162-2165
AIM:To evaluate the clinical effects of femto-LASIK using new Ziemer LDV Z6 femtosecond laser machine (Z6).
METHODS: Two - hundred cases ( 400 eyes ) was randomly separated into two groups: Group A included 200 eyes which corneal flaps were made by Z6, and Group B included rest of 200 eyes which corneal flaps were examined by a traditional Ziemer LDV CrystalLine femtosecond laser machine (CrystalLine). Visual acuity, slit lamp, refraction, Sim-K average, intraocular pressure (IOP), non-invasive tear break-up time (NIAvg-BUT), operation difficulty and complications were compared between two groups preoperatively and postoperatively.RESULTS:There was no significant differences between two groups in visual acuity, refraction, Sim-K average, IOP and NIAvg - BUT either preoperatively or 6mo postoperatively (P>0. 05). Although there were significant differences in operation difficulty and complications were found between two groups ( P< 0. 05 ), there was no serious complication in any group. Furthermore, a clear demarcation line could be observed in the cornea of Group A postoperatively.
CONCLUSION:More careful and strict requirements are needed when using the new Z6 femtosecond laser for corneal flaps.